  1. [ netinfo/c30e-interface-guide.doc ]                           [ FP, 7/88 ]
  2.  
  3.  
  4.                                           CDRL Item: B006-3
  5.                                                Date: 15 July 1987
  6.  
  7.  
  8.  
  9.  
  10.  
  11.  
  12.  
  13.  
  14.  
  15.  
  16.  
  17.                    C/30E PHYSICAL LAYER INTERFACE GUIDE
  18.  
  19.  
  20.  
  21.  
  22.                                Prepared for:
  23.  
  24.                        Defense Communications Agency
  25.                 Defense Communications Systems Organization
  26.                          Washington, DC 20305-2000
  27.  
  28.  
  29.  
  30.                        Contract No: DCA200-85-C-0023
  31.                             Task Order No: 5-44
  32.                          DCAC No: DCAC-350-180-()
  33.  
  34.  
  35.                                Prepared by:
  36.  
  37.                       BBN Communications Corporation
  38.                              50 Moulton Street
  39.                             Cambridge, MA 02238
  40.  
  41.  
  42.  
  43.  
  44.  
  45.  
  46.  
  47.                Copyright 1987 BBN Communications Corporation
  48.  
  49.  
  50.  
  51.  
  52. DCAC-350-180-( )                                                     i
  53.  
  54.                             GENERAL INFORMATION
  55.                    C/30E Physical Level Interface Guide
  56.  
  57. 1.  Purpose.  This Instruction prescribes the policy, assigns the 
  58. responsibility, and identifies the requirements for connecting an  X.25 
  59. host to a C/30E PSN by means of a MIL-STD-188-114 (balanced), EIA-232-D, 
  60. or V.35 interface.  This Instruction also identifies the requirements for 
  61. connecting one C/30E PSN to another by means of a MIL-STD-188-114 
  62. (balanced), EIA-232-D, or V.35 interface, as well as for the BELL 303 
  63. interface.
  64.  
  65. 2.  Applicability.  This Circular applies to Headquarters, DCA, and all 
  66. subordinate and affiliate activities, and all military departments and 
  67. Government agencies using or requesting DDN access.
  68.  
  69. 3.  References.
  70.  
  71.     a.  Military Standard 188-114; "Electrical Characteristics of Digital 
  72. Interface Circuits," 24 March 1976.
  73.  
  74.     b.  EIA Standard 449;  "General Purpose 37-Position and 9-Position 
  75. Interface for Data Terminal Equipment and Data Circuit-Terminating 
  76. Equipment Employing Serial Binary Data Interchange," November 1977.
  77. DCAC-350-180-( )                                                     ii
  78.  
  79.     c.  EIA Standard 232-D;   "Interface between Data  Terminal Equipment 
  80. and Data Circuit-Terminating Equipment Employing Serial Binary Data 
  81. Interchange," December 1985.
  82.  
  83.     d.  International  Standard  ISO  2593;   "Connector   Pin 
  84. Allocations  for  Use with High-Speed Data  Terminal  Equipment," 
  85. 1973-03-01 (First Edition).
  86.  
  87.     e.  Bell  System  Technical  Reference;  "Wideband  Data Stations 
  88. 303-Type," August 1966.
  89.  
  90. 4.  Policy.
  91.  
  92.     a.  The current DDN standard node supports only MIL-STD-188-114 
  93. balanced serial host interfaces.  The EIA-232 and V.35 interfaces are not 
  94. recommended for future installations, but they may be found where they are 
  95. provided by an existing installation, and it is not feasible to install a 
  96. MIL-STD-188-114 balanced interface prior to upgrading the entire node to 
  97. DDN standard.
  98.  
  99.     b.  DDN policy is that the C/30E minimum host bit rate be 9.6 kb/s for 
  100. MIL-STD-188-114, EIA-232-D, and V.35 interfaces.  DDN also supports 
  101. Extended Modem Looping (XMOD).
  102.  
  103. 5.  Responsibility.  DCA, Code B611, will ensure that this Circular is 
  104. updated to reflect current DDN standard node.
  105. DCAC-350-180-( )                                              iii
  106.  
  107.                             CONTENTS
  108.  
  109.                                             Paragraph         Page
  110.  
  111. BASIC CIRCULAR
  112.  
  113.     Purpose  . . . . . . . . . . . . . . .      1              i
  114.     Applicability  . . . . . . . . . . . .      2              i
  115.     References . . . . . . . . . . . . . .      3              i
  116.     Policy . . . . . . . . . . . . . . . .      4             ii
  117.     Responsibility . . . . . . . . . . . .      5             ii
  118.  
  119. DEFINITIONS. . . . . . . . . . . . . . . .                   vii
  120.  
  121. Chapter                                     Paragraph         Page
  122.  
  123. 1.  MIL-STD-188-114 NEIGHBOR OR NEARBY
  124.       HOST INTERFACE
  125.  
  126.         Overview . . . . . . . . . . . . .      1             1-1
  127.         Electrical Characteristics . . . .      2             1-1
  128.         Mechanical Characteristics . . . .      3             1-9
  129.         Interconnecting Cables . . . . . .      4            1-11
  130.  
  131. 2.  MIL-STD-188-114 REMOTE HOST INTERFACE
  132.  
  133.         Overview . . . . . . . . . . . . .      1             2-1
  134.         Electrical Characteristics . . . .      2             2-1
  135.         Mechanical Characteristics . . . .      3             2-6
  136.         Interconnecting Cables . . . . . .      4            2-11
  137.  
  138. 3.  EIA-232-D HOST INTERFACE
  139.  
  140.         Overview . . . . . . . . . . . . .      1             3-1
  141.         Electrical Characteristics . . . .      2             3-1
  142.         Mechanical Characteristics . . . .      3             3-8
  143.         Interconnecting Cables . . . . . .      4            3-10
  144.  
  145. 4.  V.35 HOST INTERFACE
  146.  
  147.         Overview . . . . . . . . . . . . .      1             4-1
  148.         Electrical Characteristics . . . .      2             4-1
  149.         Mechanical Characteristics . . . .      3             4-7
  150.         Interconnecting Cables . . . . . .      4             4-9
  151.  
  152. 5.  MIL-STD-188-114 NEIGHBOR OR NEARBY
  153.       TRUNK INTERFACE
  154.  
  155.         Overview . . . . . . . . . . . . .      1             5-1
  156.         Electrical Characteristics . . . .      2             5-1
  157.         Mechanical Characteristics . . . .      3            5-11
  158.         Interconnecting Cables . . . . . .      4            5-13
  159. DCAC-350-180-()                                                  iv
  160.  
  161. Chapter                                     Paragraph           Page
  162.  
  163. 6.  MIL-STD-188-114 REMOTE TRUNK INTERFACE
  164.  
  165.         Overview . . . . . . . . . . . . .      1                6-1
  166.         Electrical Characteristics . . . .      2                6-1
  167.         Mechanical Characteristics . . . .      3                6-5
  168.         Interconnecting Cables  .  . . . .      4               6-11
  169.  
  170. 7.  EIA-232-D NEIGHBOR OR NEARBY TRUNK INTERFACE
  171.  
  172.         Overview . . . . . . . . . . . . .      1                7-1
  173.         Electrical Characteristics . . . .      2                7-1
  174.         Mechanical Characteristics . . . .      3                7-7
  175.         Interconnecting Cables . . . . . .      4                7-9
  176.  
  177. 8.  V.35 REMOTE TRUNK INTERFACE
  178.  
  179.         Overview . . . . . . . . . . . . .      1                8-1
  180.         Electrical Characteristics . . . .      2                8-1
  181.         Mechanical Characteristics . . . .      3                8-6
  182.         Interconnecting Cables . . . . . .      4                8-8
  183.  
  184. 9.   BELL 303 NEIGHBOR OR NEARBY TRUNK INTERFACE
  185.  
  186.         Overview . . . . . . . . . . . . .      1                9-1
  187.         Electrical Characteristics . . . .      2                9-1
  188.         Mechanical Characteristics . . . .      3                9-8
  189.         Interconnecting Cables . . . . . .      4               9-10
  190.  
  191. 10.  BELL 303 REMOTE TRUNK INTERFACE
  192.  
  193.         Overview . . . . . . . . . . . . .      1               10-1
  194.         Electrical Characteristics . . . .      2               10-1
  195.         Mechanical Characteristics . . . .      3               10-3
  196.         Interconnecting Cables . . . . . .      4               10-9
  197.  
  198.  
  199.  
  200.  
  201.  
  202.  
  203. DCAC-350-180-( )                                             v
  204.  
  205.                           ILLUSTRATIONS
  206.  
  207. Table                                                         Page
  208.  
  209.  
  210. 1-1     Signal Name Equivalency Table . . . . . . . . .        1-2
  211. 1-2     Frequencies Provided by the FDBCLK Fantail  . .        1-3
  212. 1-3     DDN Standard Node Interchange Circuit Use . . .        1-8
  213. 1-4     DDN Standard Node EIA-449 (DTE)
  214.           Connector Pinout  . . . . . . . . . . . . . .       1-10
  215. 2-1     Remote-Modem DTE Interface Connector Pinout . .        2-8
  216. 2-2     KGAB - Remote Host Connector Pinout . . . . . .        2-9
  217. 2-3     KGAB - Remote Modem Connector Pinout  . . . . .       2-10
  218. 2-4     Remote Interface Cables . . . . . . . . . . . .       2-11
  219. 3-1     Signal Name Equivalency Table . . . . . . . . .        3-3
  220. 3-2     EIA-232-D Interchange Circuit Use . . . . . . .        3-7
  221. 3-3     EIA-232-D Connector Pinout  . . . . . . . . . .        3-9
  222. 4-1     V.35 Interchange Circuit Use  . . . . . . . . .        4-6
  223. 4-2     V.35 34-Pin and 37-pin Connector Pinout . . . .        4-8
  224. 5-1     Signal Name Equivalency Table . . . . . . . . .        5-2
  225. 5-2     Frequencies Provided by the MMBC Fantail. . . .        5-3
  226. 5-3     DDN Standard Node MMB*/MMBC                           
  227.           Interchange Circuit Use  . . . .  . . . . . .       5-10
  228. 5-4     DDN Standard Node EIA-449 (DTE)
  229.           Connector Pinout  . . . . . . . . . . . . . .       5-12
  230. 6-1     Remote-Modem DCE Interface Connector Pinout . .        6-8
  231. 6-2     KGAB - Remote C/30E Connector Pinout. . . . . .        6-9
  232. 6-3     KGAB - Remote Modem Connector Pinout  . . . . .       6-10
  233. 6-4     Remote Interface Cables . . . . . . . . . . . .       6-11
  234. 7-1     Signal Name Equivalency Table . . . . . . . . .        7-3
  235. 7-2     EIA-232-D Interchange Circuit Use . . . . . . .        7-6
  236. 7-3     EIA-232-D Connector Pinout  . . . . . . . . . .        7-8
  237. 8-1     V.35 Trunk Interchange Circuit Use  . . . . . .        8-5
  238. 8-2     V.35 34-Pin and 37-pin Connector Pinout . . . .        8-7
  239. 9-1     Signal Name Equivalency Table   . . . . . . . .        9-3
  240. 9-2     BELL 303 Trunk Interface Circuit Use  . . . . .        9-7
  241. 9-3     DDN Standard Node EIA-449 (DTE) Connector Pinout       9-9
  242. 10-1    DTE Interface Connector Pinout  . . . . . . . .       10-6
  243. 10-2    DCE BELL 303 Interface Connector Pinout . . . .       10-7
  244. 10-3    KGAB-Remote Modem Connector Pinout. . . . . . .       10-8
  245. 10-4    Remote Interface Cables . . . . . . . . . . . .       10-9
  246. DCAC-350-180-( )                                                 vi
  247.  
  248. Figure                                                           Page
  249.  
  250. 1-1     C/30E PSN and Nearby EIA-449 Host Cabling
  251.           Diagram (C/30E Sources Clock). . . . . . . . . .       1-12
  252. 1-2     Cable Example: C/30E PSN to EIA-449 Nearby
  253.           Host (C/30E Sources Clock) . . . . . . . . . . .       1-13
  254. 2-1     Demarcation Point "A" Between the C/30E and
  255.           Remote Host. . . . . . . . . . . . . . . . . . .        2-3
  256. 2-2     Demarcation Point "B" Between the KGAB and
  257.           Remote Host. . . . . . . . . . . . . . . . . . .        2-3
  258. 2-3     Functional Signal Flow Between a Nearby Modem and
  259.           C/30E, or a KGAB and a Remote Host . . . . . . .        2-7
  260. 2-4     C/30E and Remote Host Cabling Diagram. . . . . . .       2-12
  261. 2-5     C/30E and Remote Host Cabling Diagram
  262.           (with Cryptographic Devices) . . . . . . . . . .       2-12
  263. 3-1     C/30E PSN and Nearby EIA-232-D Host Cabling
  264.           Diagram. . . . . . . . . . . . . . . . . . . . .       3-10
  265. 3-2     Cable Example: C/30E PSN to Nearby EIA-232-D
  266.           Host . . . . . . . . . . . . . . . . . . . . . .       3-11
  267. 4-1     C/30E PSN and Nearby V.35 Host Cabling Diagram . .        4-9
  268. 4-2     Cable Example: C/30E PSN to Nearby V.35 Host . . .       4-10
  269. 5-1     C/30E EIA-449 PSN and Nearby EIA-449 PSN Cabling
  270.           Diagram MMBC (C/30E Sources Clock) . . . . . . .       5-15
  271. 5-2     C/30E PSN with MMBC to EIA-449 Nearby PSN Cabling 
  272.           Diagram with MMBC-MMBC (C/30E Sources Clock) . .       5-15
  273. 5-3     Cabling Example: C/30E with MMB to EIA-449 Nearby
  274.           PSN with MMBC (C/30E Sources Clock). . . . . . .       5-16
  275. 5-4     Cabling Example: C/30E with MMBC to EIA-449 Nearby
  276.           PSN with MMBC (C/30E Sources Clock). . . . . . .       5-17
  277. 6-1     Demarcation Point "A" Between the C/30E and
  278.           Remote C/30E . . . . . . . . . . . . . . . . . .        6-3
  279. 6-2     Demarcation Point "B" Between the KGAB and
  280.           Remote C/30E PSN  . . . .  . . . . . . . . . . .        6-3
  281. 6-3     Functional Signal Flow Between a Nearby Modem and
  282.           C/30E, or an SR(ON) NS(OFF) KGAB and a Remote PSN.      6-7
  283. 6-4     C/30E and Remote Host Cabling Diagram. . . . . . .       6-12
  284. 6-5     C/30E and Remote Trunk Cabling Diagram
  285.           (with Cryptographic Devices) . . . . . . . . . .       6-12
  286. 7-1     C/30E PSN and Nearby EIA-232-D PSN Cabling
  287.           Diagram  . . . . . . . . . . . . . . . . . . . .        7-9
  288. 8-1     C/30E PSN and Remote V.35 PSN Cabling Diagram  . .        8-8
  289. 8-2     Cable Example: C/30E PSN to Remote V.35 PSN  . . .        8-9
  290. 9-1     BELL 303 MMI to BELL 303 MML Cabling Example . . .       9-11
  291. 9-2     BELL 303 Trunk Interface Cabling Example . . . . .       9-12
  292. 10-1    Demarcation Point "A" Between the C/30E and
  293.           Remote C/30E . . . . . . . . . . . . . . . . . .       10-2
  294. 10-2    BELL 303 Remote Trunk Interchange Circuit Use. . .       10-5
  295.  
  296.  
  297. DCAC-350-180-( )                                                 vii
  298.  
  299.                                 DEFINITIONS
  300.  
  301. C/30E.  X.25-based communication processor made by BBN Communications 
  302. Corporation.  Used in Packet-Switching Network applications.
  303.  
  304. DCE.  Data Circuit-Terminating Equipment.
  305.  
  306. DC-37P.  37-pin male connector.
  307.  
  308. DC-37S.  37-pin female connector.
  309.  
  310. DDN.  Defense Data Network.
  311.  
  312. DPPC.  Digital Patch Panel connected between the DCE and the encryption 
  313. device.
  314.  
  315. DPPE.  Digital Patch Panel connected between the DTE and the encryption 
  316. device.
  317.  
  318. DTE.  Data Terminal Equipment.
  319.  
  320. EIA.  Electronic Industries Association.
  321.  
  322. EMI.  Electromagnetic Interference.
  323.         
  324. DCAC-350-180-( )                                                 viii
  325.  
  326. FDBCLK.  MSYNC-driven clock-sourcing MIL-STD-188-114 adapter  (fantail)  
  327. containing EIA-449  connectors.   The  FDBCLK fantail can be used to 
  328. source clock.
  329.  
  330. FDB3.  MSYNC-driven MIL-STD-188-114 fantail containing EIA-449 
  331. connectors.  FDB3 cannot provide clock.
  332.  
  333. FD4.  Fantail containing EIA-232-D connectors.
  334.  
  335. FPA.  Fixed Plant Adapters: Complete assembly consisting of two KGABs, 
  336. space for two KG-84As, and one FPA shelf that supports the assembly in the 
  337. encryption cabinet.
  338.  
  339. KGAB.  Interfaces a KG-84A with a communications line by providing for 
  340. cable termination, filter isolation, and update counter support.
  341.  
  342. KG-84A.  Provides standard link encryption to all interswitch trunks and 
  343. host access lines on the MILNET.  Not used for collocated equipment.
  344.  
  345. MII Board.  Input/output motherboard used in C/30E PSNs to interface with 
  346. communications lines leading to other DDN PSNs.
  347.  
  348. MMBC Board.  Daughterboard emulating a MIL-STD-188-114 DCE, thus providing 
  349. clock. Its DTE counterpart is the MMB board.
  350.  
  351. MMI Board. Daughterboard emulating a BELL 303 DTE.
  352.  
  353. DCAC-350-180-( )                                                 ix
  354.  
  355. MML Board. Daughterboard emulating a BELL 303 DCE.
  356.  
  357. MS Connection.  KGAB Connectors.
  358.  
  359. MSYNC.  Input/output motherboard that is used in C/30E PSNs to interface 
  360. with synchronous host access lines.
  361.  
  362. PSN.  Packet Switch Node used in the DDN to provide full service network 
  363. access ports for hosts and trunks.  PSN and C/30E are used interchangeably 
  364. in this document.
  365.  
  366. Synchronous Devices.   Require a clock signal to operate the 
  367. communications interface.
  368.  
  369. TEMPEST.  Limits compromising electromagnetic emanations from  
  370. communications  equipment.
  371.  
  372. Trunk. Communications link providing an interface between two nearby or 
  373. remote PSNs, hence a PSN-to-PSN interface.
  374.  
  375. DCAC-350-180-( )                                                     1-1
  376.  
  377.  
  378.       CHAPTER 1.  MIL-STD-188-114  NEIGHBOR OR NEARBY HOST INTERFACE
  379.  
  380. 1.  Overview.  This chapter describes the electrical and mechanical 
  381. characteristics of the MIL-STD-188-114 balanced DTE interface that 
  382. connects the C/30E PSN with a neighbor/nearby host or a modem.  This 
  383. interface is largely in conformance with the EIA-449/422 standard 
  384. considered the general commercial equivalent to MIL-STD-188-114.  
  385. Exceptions to the standard include the required signal states for Clear to 
  386. Send and Receiver Ready as well as the open circuit voltage.  For ease of 
  387. reference, table 1-1 equates the EIA-449, EIA-232, and CCITT interface 
  388. signal names.  However, in the rest of chapters 1 and 2, only the EIA-449 
  389. signal name will be used.
  390.  
  391. 2.  Electrical Characteristics.
  392.  
  393.     a.  Voltage Levels.  The electrical measurements of the C/30E 188-114 
  394. interface circuits are in accordance with MIL-STD-188-114, chapter 5, 
  395. except with regard to subsection 5.1.1.2: Open Circuit Measurement.  The 
  396. C/30E open circuit driver voltage, measured in   accordance with 5.1.1.2, 
  397. is less than +9.0V for balanced drivers and +4.5V for unbalanced drivers.
  398.  
  399. DCAC-350-180-( )                                                     1-2
  400.  
  401.  
  402.                  TABLE 1-1.  SIGNAL NAME EQUIVALENCY TABLE
  403.  
  404.  
  405.  
  406. SG   Signal Ground                 AB     Signal Ground                      102      Signal Ground
  407. SC   Send Common                   --                                        102a     DTE Common
  408. RC   Receive Common                --                                        102b     DCE Common
  409. SD   Send Data                     BA     Transmitted Data                   103      Transmitted Data
  410. RD   Receive Data                  BB     Received Data                      104      Received Data
  411. RS   Request To Send               CA     Request To Send                    105      Request To Send
  412. CS   Clear To Send                 CB     Clear To Send                      106      Ready For Sending
  413. DM   Data Mode                     CC     Data Set Ready (DCE Ready)         107      Data Set Ready
  414. TR   Terminal Ready                CD     Data Terminal Ready (DTE Ready)    108/2    Data         Terminal Ready
  415. RR   Receiver Ready                CF     Received Line Signal Detector      109      Data Channel Received Line
  416.                                                                                       Signal Detector
  417. IS   Terminal In Service           --                                        ---
  418. SQ   Signal Quality                CG     Signal Quality Detector            110      Data Signal Quality
  419.                                                                                                    Detector
  420. SR   Signaling Rate Selector       CH     Data Signal Rate Selector          111      Data Signaling Rate
  421.                                            (DTE Source)                                Selector (DTE Source)
  422. SI   Signaling Rate                CI     Data Signal Rate Selector          112      Data Signaling Rate
  423.       Indicator                            (DCE Source)                                Selector (DCE Source)
  424. NS   New Signal                    --                                        ---
  425. TT   Terminal Timing               DA     Transmitter Signal Element Timing  113      Transmitter Signal Element
  426.                                            (DTE Source)                                Timing (DTE Source)
  427. ST   Send Timing                   DB     Transmitter Signal Element Timing  114      Transmitter Signal Element
  428.                                            (DCE Source)                                Timing (DCE Source)
  429. RT   Receive Timing                DD     Receiver Signal Element Timing     115      Receiver Signal Element
  430.                                                                                                     Timing (DCE Source)
  431. SS   Select Standby                --                                        116      Select Standby
  432. SB   Standby Indicator             --                                        117      Standby Indicator
  433.  
  434. IC   Incoming Call                 CE     Ring Indicator                     125      Calling Indicator
  435. SF   Select Frequency              --                                        126      Select Transmit Frequency
  436. LL   Local Loopback                LL     Local Loopback                     141      Local Loopback
  437. RL   Remote Loopback               RL     Remote Loopback                    140      Remote Loopback
  438. TM   Test Mode                     TM     Test Mode                          142      Test Indicator
  439. AT   Alternate Timing*             --                                        142
  440.  
  441.  
  442. *  Alternate Timing is provided on spare pins 3 and 21 when
  443.    the FDBCLK clock-sourcing fantail is providing clock.
  444. DCAC-350-180-( )                                                     1-3
  445.  
  446.     b.  Clocking.  Two fantails, FDB3 and FDBCLK, provide the EIA-449 
  447. connectors that terminate cables from all I/O interfaces.  The fantail 
  448. connectors are configured as DTEs.  When the FDB3 fantail is used, the DCE 
  449. must provide clock because the FDB3 fantail does not support 
  450. clock-sourcing capability.  When FDBCLK, a clock-sourcing enhanced 
  451. fantail, is used, either the DTE or DCE can provide clock.
  452.  
  453.         (1)  FDB Fantail Clock Rates.  FDBCLK and FDB3 interface hardware 
  454. support any external clock between 1.2 kb/s and 112 kb/s.  However, DDN 
  455. policy is that the minimum PSN host bit rate be 9.6 kb/s.  When FDBCLK 
  456. clock-sourcing capability is used, the FDBCLK on-board clock generator 
  457. provides the frequencies described in table 1-2.
  458.  
  459.  
  460.           TABLE 1-2.  FREQUENCIES PROVIDED BY THE FDBCLK FANTAIL
  461.         
  462.                                                                           
  463.  
  464. Clock Frequency                                  Accuracy* 
  465.  
  466. 112kHz, 56kHz, 19.2kHz,9.6kHz, 4.8kHz, 2.4kHz    +0.05% (500 ppm**)
  467.  
  468. 64kHz, 50kHz                                     +0.005% (50 ppm)
  469.  
  470.                                                                           
  471.  
  472. *  Accuracy over a temperature range of 10 to 30 degrees C.
  473. ** PPM = Parts Per Million
  474. DCAC-350-180-( )                                                     1-4
  475.  
  476.         (2)  Signaling Sense.  Signaling sense for balanced and unbalanced 
  477. circuits is in accordance with EIA-422-A with the exception that the 
  478. differential voltage applied to the interconnecting cable is in the range 
  479. of 2 volts to 9 volts for the C/30E.  As defined in RS-422-A, ON (0, 
  480. Space, or +) is generated when A terminal is positive with respect to the 
  481. B terminal, and OFF (1,  MARK, or -) is generated when A terminal is 
  482. negative with respect to the B terminal.
  483.  
  484.     c.  Bit Rate and Cable Length.  Interconnecting cable length and its 
  485. relation to data signaling rates is in accordance with EIA Standard 449, 
  486. section 6.10, and EIA Standard 422-A, section 4.3 and the appendix.
  487.  
  488.         (1)  Maximum Cable Length.  The maximum length of the cable is 
  489. 1000 feet.
  490.  
  491.         (2)  Slew Rate Limiting.  Signal rise time is set to 1 microsecond 
  492. (100 kb/s value).
  493.  
  494.     d.  Interchange  Circuits.  The EIA-449 interface for the C/30E is 
  495. provided by the  MSYNC motherboard in conjunction  with the appropriate 
  496. daughterboards to fulfill the MIL-STD-188-114 I/O option.
  497.  
  498.         (1)  Electrical Use of Interchange Circuits.  The DDN electrical 
  499. use of interchange circuits is either static or active.  Static circuits 
  500. are tied by the hardware so that the signal state remains constant on the 
  501. line, either ON or OFF.  Active circuits change their state under program 
  502. control.  DDN use of the interchange circuits is shown in table 1-3.
  503. DCAC-350-180-( )                                                     1-5
  504.  
  505.         (2)  Software Use of Interchange Circuits.  Interchange circuit 
  506. signals are used by the software in different ways.  Active circuits are 
  507. under program control: either the software reacts to the circuit signal 
  508. when it changes, or the software can assert a circuit when necessary (such 
  509. as LL which can be used by operations personnel for testing connections).  
  510. Unsupported circuits either are not read by the software or a value is 
  511. written to the circuit by the software and that value does not change 
  512. during operation.  Table 1-3 provides a list of circuits and their use.
  513.  
  514.         (3)  Interchange Circuit Definitions.  For additional information 
  515. about these interchange circuits, see EIA Standard 449.  The following 
  516. descriptions assume use of full period/full duplex circuits, with flow 
  517. control handled at higher levels.
  518.  
  519.              (a)  Signal Ground.  See EIA Standard EIA-449.
  520.  
  521.              (b)  Send Common.  See EIA Standard EIA-449.
  522.  
  523.              (c)  Receive Common.  See EIA Standard EIA-449.
  524.  
  525.              (d)  Terminal in Service.  IS is tied ON by the hardware.
  526.  
  527.              (e)  Incoming Call.  IC is reported to the Monitoring Center; 
  528. however, its value has no software effect.
  529.  
  530.              (f)  Terminal Ready.  TR is asserted ON by PSN software when 
  531. the link is initialized.
  532. DCAC-350-180-( )                                                     1-6
  533.  
  534.              (g)  Data Mode.  DM must be asserted ON by the DCE and is 
  535. monitored by the PSN software.
  536.  
  537.              (h)  Send Data.  See EIA Standard EIA-449.
  538.  
  539.              (i)  Receive Data.  See EIA Standard EIA-449.
  540.  
  541.              (j)  Terminal Timing.  See EIA Standard EIA-449.
  542.  
  543.              (k)  Send Timing.  See EIA Standard EIA-449.
  544.  
  545.              (l)  Receive Timing.  See EIA Standard EIA-449.
  546.  
  547.              (m)  Request to Send.  RS is asserted ON by PSN software when 
  548. the link is initialized.
  549.  
  550.              (n)  Clear to Send.  CS must be asserted ON by the DCE and is 
  551. monitored by PSN software.  If the signal state on this line changes to 
  552. OFF, the software macrocode will stop data transmission.
  553.  
  554.              (o)  Receiver Ready .  RR must be asserted ON by the DCE and 
  555. is monitored by PSN software.  If the signal state on this line changes to 
  556. OFF, the software macrocode will stop receiving data.
  557.  
  558.              (p)  Signal Quality.  SQ is reported to the Monitoring 
  559. Center; however, its value has no software effect.
  560.  
  561. DCAC-350-180-( )                                                     1-7
  562.  
  563.              (q)  New Signal.  Ns is tied OFF by the hardware.
  564.  
  565.              (r)  Select Frequency.  SF/SR is electrically active and 
  566. asserted OFF by the PSN software when the link is initialized.
  567.  
  568.              (s)  Signaling Rate Selector.  See Select Frequency, 2.d.3.r 
  569. above for a description.
  570.  
  571.              (t)  Signaling Rate Indicator.  SI is reported to the 
  572. Monitoring Center; however, its value has no software effect.
  573.  
  574.              (u)  Local Loopback.  LL is electrically active, but asserted 
  575. OFF by PSN software when the link is initialized.  LL can be controlled by 
  576. the Monitoring Center.
  577.  
  578.              (v)  Remote Loopback.  RL is electrically active, but 
  579. asserted OFF by PSN software when the link is initialized.  RL is 
  580. available for Monitoring Center control.
  581.  
  582.              (w)  Test Mode.  TM is reported to the Monitoring Center; 
  583. however, its value has no software effect.
  584.  
  585.              (x)  Select Standby.  SS is tied OFF by hardware.
  586.  
  587.              (y)  Standby Indicator.  SB is not connected.
  588.  
  589. DCAC-350-180-( )                                                     1-8
  590.  
  591.            TABLE 1-3.  DDN STANDARD NODE INTERCHANGE CIRCUIT USE
  592.  
  593.  
  594.  
  595. 449                                            Electrical        Required State of     Comments
  596. ID      EIA-449 Name          Source           Circuit         Control/Status Sigals
  597.  
  598. SG      Signal Ground         DTE/DCE          Ground                   N/A            Ground
  599. SC      Send Common           DTE              Ground                   N/A            Common
  600. RC      Receive Common        DCE              Ground                   N/A            Common
  601. SD      Send Data             DTE              Active                   N/A            Data Circuit
  602. RD      Receive Data          DCE              Active                   N/A            Data Circuit
  603. RS      Request to Send       DTE              Active                   ON             Asserted On by PSN software.
  604. CS      Clear to Send         DCE              Active                   ON             Asserted On by DCE, and
  605.                                                                                        monitored by PSN software to
  606.                                                                                        determine line status.
  607. DM      Data Mode             DCE              Active                   ON             Asserted ON by DCE, and
  608.                                                                                        monitor by PSN sofware.
  609. TR      Terminal Ready        DTE              Active                   ON             Asserted ON by PSN sofware.
  610. RR      Receiver Ready        DCE              Active                   ON             Asserted ON by DCE, and
  611.                                                                                        monitor by PSN software to
  612.                                                                                        determine line status.
  613. SQ      Signal Quality        DCE              Active                   Don't Care     Monitored by PSN software, but
  614.                                                                                        no action is taken.
  615. SF/SR   Select Frequency/     DTE              Active                   OFF            Asserted OFF by PSN software.
  616.          Signaling Rate Sel.
  617. SI      Signaling Rate        DCE              Active                   Don't Care     Monitored by PSN software,but
  618.          indicator                                                                     no action is taken.
  619. TT      Terminal Timing       DTE              Active                   N/A            Timing circuit for Transmitted
  620.                                                                                        Data when PSN supplies timing.
  621. ST      Send Timing           DCE              Active                   N/A            Timing circuit for Received
  622.                                                                                        Data when DCE provides timing.
  623. RT      Receive Timing        DCE              Active                   N/A            Timing circuit for Received
  624.                                                                                        Data when DCE provides timing.
  625. SS      Select Standby        DTE              Static                   OFF            Tied OFF by hardware.
  626. SB      Standby Indicator     DCE              Not Connected            Don't Care     Not connected in PSN.
  627. IC      Incoming Call         DCE              Active                   Don't Care     Monitored by PSN software, but
  628.                                                                                        no action is taken.
  629. LL      Local Loopback        DTE              Active                   OFF            Initialized to OFF by
  630.                                                                                        software.  Available for
  631.                                                                                        Monitoring Center control.
  632. RL      Remote Loopback       DTE              Active                   OFF            Initialized to OFF by
  633.                                                                                        software.  Available for 
  634.                                                                                        Monitoring Center control.
  635. TM      Test Mode             DCE              Active                   Don't Care     Monitored by PSN software, but
  636.                                                                                        no action is taken.
  637. NS      New Signal            DTE              Static                   OFF            Tied OFF by hardware.
  638. IS      Terminal in Service   DTE              Static                   ON             Tied ON by hardware.
  639. AT      Alternative Timing    DTE              Active                   N/A            Special timing circuit for
  640.                                                                                        Received Data when the PSN
  641.                                                                                        supplies timing.
  642.  
  643.  
  644.  
  645.  
  646. NOTE:  N/A = Not Applicable
  647. DCAC-350-180-( )                                                     1-9
  648.  
  649. 3.  Mechanical Characteristics.  All EIA-449/422 connectors offered for 
  650. the C/30E meet the following specifications.
  651.     
  652.     a.  Interface Connectors.  All C/30E EIA-449 connectors are DC-37P 
  653. type (male) connectors.
  654.  
  655.         (1)  Intermating dimensions are in accordance with EIA-449, 
  656. section 3.3.1.
  657.  
  658.         (2)  The means for C/30E DTE connectors to latch and unlatch from 
  659. the latching blocks on the DCE connector are within the dimensions 
  660. specified in EIA-449, section 3.3.2.  DDN uses the English 4-40 thread 
  661. latching block.
  662.     
  663.     b.  Connector Contact Assignments.  All C/30E EIA-449/422 contact 
  664. assignments are in accordance with EIA-449, section 3.4.  Table 1-4 
  665. provides the DDN standard node connector pinout.   The signals are used as 
  666. specified in section 2.d.3.
  667. DCAC-350-180-( )                                                     1-10
  668.  
  669.        TABLE 1-4.  DDN STANDARD NODE EIA-449 (DTE) CONNECTOR PINOUT
  670.  
  671.                                                                           
  672.  
  673. Pin     EIA     CCITT         Name
  674.         ID      ID
  675.  
  676. 1       FG                    Frame Ground           
  677. 2       SI      111           Signaling Rate Indicator
  678. 20      RC      102b          Receive Common
  679. 3       AT      ---           Alternate Timing +     
  680. 21      AT      ---           Alternate Timing -
  681. 4       SD      103           Send Data +            
  682. 22      SD      103           Send Data -
  683. 5       ST      114           Send Timing +          
  684. 23      ST      114           Send Timing -
  685. 6       RD      104           Receive Data +                  
  686. 24      RD      104           Receive Data -         
  687. 7       RS      105           Request to Send +      
  688. 25      RS      105           Request to Send -
  689. 8       RT      115           Receive Timing +       
  690. 26      RT      115           Receive Timing -
  691. 9       CS      106           Clear to Send +
  692. 27      CS      106           Clear to Send -
  693. 10      LL      141           Local Loopback
  694. 28      IS      ---           Terminal in Service    
  695. 11      DM      107           Data Mode +
  696. 29      DM      107           Data Mode -
  697. 12      TR      108.2         Terminal Ready +       
  698. 30      TR      108.2         Terminal Ready -
  699. 13      RR      109           Receiver Ready +       
  700. 31      RR      109           Receiver Ready -
  701. 14      RL      140           Remote Loopback
  702. 32      SS      116           Select Standby         
  703. 15      IC      125           Incoming Call
  704. 33      SQ      110           Signal Quality
  705. 16      SF/SR   126           Select Frequency/Signaling Rate
  706.                                Selector
  707. 34      NS      ---           New Signal             
  708. 17      TT      113           Terminal Timing +      
  709. 35      TT      113           Terminal Timing -
  710. 18      TM      142           Test Mode
  711. 36      SB      117           Standby Indicator
  712. 19      SG      102           Signal Ground          
  713. 37      SC      102a          Send Common
  714.  
  715.                                                                           
  716. DCAC-350-180-( )                                                     1-11
  717.  
  718. 4.  Interconnecting Cables.
  719.  
  720.     a.  Interconnecting cables are in accordance with MIL-STD-188-114.  
  721. They must be low capacitance, multiple twisted pair that meet the 
  722. following specifications resulting in  a transmission line with a nominal 
  723. characteristic impedance on the order of 100 ohms to frequencies greater 
  724. than 100 kHz, and a dc series loop resistance not exceeding 240 ohms.  The 
  725. overall braid shield must have at least 85% coverage.
  726.  
  727.         (1)  Conductor Size.   Interconnecting cables should be in 
  728. accordance with MIL-STD-188-114, Appendix 10, with regard to conductor 
  729. size (subsection 10.1.1).  Interconnecting cables or wires should be 
  730. composed of wires of a 24 AWG or larger conductor for solid or stranded 
  731. copper wires, or for non-copper conductors a sufficient size to yield a dc 
  732. wire resistance not to exceed 30 ohms/1000 feet per conductor.
  733.  
  734.         (2)  Mutual Pair Capacitance.   In accordance with 
  735. MIL-STD-188-114, the capacitance between one wire in the pair to the other 
  736. wire in the pair should not exceed 20 picofarads/foot, and the value 
  737. should be reasonably uniform over the length of the wire or cable.
  738.  
  739.         (3)  Stray Capacitance.   In accordance with MIL-STD-188-114, the 
  740. capacitance between one wire in the cable to all others in the cable 
  741. sheath, with all others connected to ground, should not exceed 40 
  742. picofarads/foot, and should be reasonably uniform for a given conductor 
  743. over the length of the wire or cable.
  744.  
  745. DCAC-350-180-( )                                                     1-12
  746.  
  747.              (4)  Pair-to-Pair Balanced Crosstalk.  In accordance with 
  748. MIL-STD-188-114, Appendix 10, with regard to pair-to-pair balanced 
  749. crosstalk (subsection 10.1.4), the crosstalk from on pair of wires to any 
  750. other pair in the same cable sheath should have a minimum value of 40 dB 
  751. of attenuation measured at 150 kHz.
  752.  
  753.           (b)  Figure 1-1 is a cabling diagram of a C/30E PSN connected to 
  754. a nearby EIA-449 host, and figure 1-2 is an example of a cable (BBNCC P/N# 
  755. 2409313G01) that could be used to interconnect them.
  756.  
  757.  
  758.  
  759.  
  760.      +---------------------------------------------------------------+
  761.      |                                                               |
  762.      |               DC-37S                    DC-37S                |
  763.      |                 /                           \                 |
  764.      | +----------+  /                               \  +----------+ |
  765.      | | EIA-449  |--+            2409318G01         +--| EIA-449  | |
  766.      | | DTE Host |P1|===============================|P2|  C/30E   | |
  767.      | |          |--+                               +--|  (DTE)   | |
  768.      | +----------+                                     +----------+ |
  769.      |                                                               |
  770.      |                                                               |
  771.      |                                                               |
  772.      |                                                               |
  773.      +---------------------------------------------------------------+
  774.  
  775.       FIGURE 1-1.  C/30E PSN AND NEARBY EIA-449 HOST CABLING DIAGRAM
  776.                    (C/30E SOURCES CLOCK)
  777. DCAC-350-180-( )                                                     1-13
  778.  
  779.  
  780.        +-----------------------------------------------------------+
  781.        |     DTE Host                                    C/30E     |
  782.        |        P1                                         P2      |
  783.        |      DC-37S                                     DC-37S    |
  784.        | Pin#     Signal                            Signal    Pin# |
  785.        |  +/-       +/-   Shield             Shield   +/-      +/- |
  786.        |  1         FG  >--------+         +-------<  FG       1   |
  787.        |                                                           |
  788.        |                                    +------<  AT      3/21 |
  789.        |                                    |                      |
  790.        |                  Pair #            |                      |
  791.        |  4/22      SD  >-(1)------\   /----|------<  SD      4/22 |
  792.        |                             /      |                      |
  793.        |  5/23      ST  >-(2)------/---\----+---+--<  ST      5/23 |
  794.        |                         /       \      |                  |
  795.        |  6/24      RD  >-(3)--/           \----|--<  RD      6/24 |
  796.        |                                        |                  |
  797.        |  8/26      RT  >-(4)-\                 +--<  RT      8/26 |
  798.        |                       \                                   |
  799.        |  7/25      RS  >-(5)---\-------\   /------<  RS      7/25 |
  800.        |                         \        \                        |
  801.        |  11/29     DM  >-(6)--+--\-----/   \--+---<  DM     11/29 |
  802.        |                       |   \           |                   |
  803.        |  9/27      CS  >------+    \          +---<  CS      9/27 |
  804.        |                       |     \         |                   |
  805.        |  13/31     RR  >------+       \       +---<  RR     13/31 |
  806.        |                                 \                         |
  807.        |  19/37  SG/SC  >-(7)-+------------\-------<  SG/SC  19/37 |
  808.        |                      |              \                     |
  809.        |  17/35     TT  >-----|--(12)---No     \---<  TT     17/35 |
  810.        |                      |         Connection (NC)            |
  811.        |                      +--(8)----NC                         |
  812.        |                      |                                    |
  813.        |                      +--(9)----NC                         |
  814.        |                      |                                    |
  815.        |                      +--(10)---NC                         |
  816.        |                      |                                    |
  817.        |                      +--(11)---NC                         |
  818.        |                      |                                    |
  819.        |                      +--(sp)---NC                         |
  820.        |                                                           |
  821.        +-----------------------------------------------------------+
  822.      
  823.        FIGURE 1-2.  CABLE EXAMPLE: C/30E PSN TO EIA-449 NEARBY HOST
  824.                     (C/30E SOURCES CLOCK)
  825.  
  826.  
  827. DCAC-350-180-( )                                                     1-14
  828.  
  829.  
  830.        +-----------------------------------------------------------+
  831.        |     DTE Host                                    C/30E     |
  832.        |        P1                                         P2      |
  833.        |      DC-37S                                     DC-37S    |
  834.        | Pin#     Signal                            Signal    Pin# |
  835.        |  +/-       +/-   Shield             Shield   +/-      +/- |
  836.        |  1         FG  >--------+         +-------<  FG       1   |
  837.        |                                                           |
  838.        |                                    +------<  AT      3/21 |
  839.        |                                    |                      |
  840.        |                  Pair #            |                      |
  841.        |  4/22      SD  >-(1)------\   /----|------<  SD      4/22 |
  842.        |                             /      |                      |
  843.        |  5/23      ST  >-(2)------/---\----+---+--<  ST      5/23 |
  844.        |                         /       \      |                  |
  845.        |  6/24      RD  >-(3)--/           \----|--<  RD      6/24 |
  846.        |                                        |                  |
  847.        |  8/26      RT  >-(4)-\                 +--<  RT      8/26 |
  848.        |                       \                                   |
  849.        |  7/25      RS  >-(5)---\-------\   /------<  RS      7/25 |
  850.        |                         \        \                        |
  851.        |  11/29     DM  >-(6)--+--\-----/   \--+---<  DM     11/29 |
  852.        |                       |   \           |                   |
  853.        |  9/27      CS  >------+    \          +---<  CS      9/27 |
  854.        |                       |     \         |                   |
  855.        |  13/31     RR  >------+       \       +---<  RR     13/31 |
  856.        |                                 \                         |
  857.        |  19/37  SG/SC  >-(7)-+------------\-------<  SG/SC  19/37 |
  858.        |                      |              \                     |
  859.        |  17/35     TT  >-----|--(12)---No     \---<  TT     17/35 |
  860.        |                      |         Connection (NC)            |
  861.        |                      +--(8)----NC                         |
  862.        |                      |                                    |
  863.        |                      +--(9)----NC                         |
  864.        |                      |                                    |
  865.        |                      +--(10)---NC                         |
  866.        |                      |                                    |
  867.        |                      +--(11)---NC                         |
  868.        |                      |                                    |
  869.        |                      +--(sp)---NC                         |
  870.        |                                                           |
  871.        +-----------------------------------------------------------+
  872.      
  873.        FIGURE 1-2.  CABLE EXAMPLE: C/30E PSN TO EIA-449 NEARBY HOST
  874.                     (C/30E SOURCES CLOCK)
  875.  
  876.  
  877. DCAC-350-180-( )                                                     2-1
  878.  
  879.  
  880.              CHAPTER 2.  MIL-STD-188-114  REMOTE HOST INTERFACE
  881.  
  882. 1.  Overview.  This chapter describes the electrical and mechanical 
  883. characteristics of the MIL-STD-188-114 balanced remote host interface.     
  884. This chapter documents the interface between the remote modem and the      
  885. host (demarcation point A in figure 2-1) with no intervening       
  886. cryptographic devices (KG-84As).  Eventually KG-84As will be required      
  887. for all host access circuits; therefore, chapter 2 also provides an      
  888. example of the cabling that connects from the remote modem to the remote   
  889. Fixed Plant Adapter (FPA) and then to the host (demarcation point B in    
  890. figure 2-2).
  891.  
  892. 2.  Electrical Characteristics.
  893.  
  894.     a.  Voltage Levels.  The modems used will conform to EIA-449.  The 
  895. electrical interface of the KG-84A is in accordance with MIL-STD-188-114, 
  896. chapter 5, except with regard to subsection 5.1.1.2: Open Circuit   
  897. Measurement.  The open circuit driver voltage, measured in accordance      
  898. with 5.1.1.2, is less than +10.0V for balanced drivers and +5.0V for  
  899. unbalanced drivers.
  900.  
  901. DCAC-350-180-( )                                                     2-2
  902.  
  903.  
  904.     b.  Clocking.
  905.  
  906.         (1)  Modem Clocking.  The modem supplies timing on the Send       
  907. Timing and Receive Timing circuits.  Terminal Timing isnot supported       
  908. for remote host interfaces.  While the DDN hardware will support         
  909. between 1.2 kb/s and 64 kb/s, DDN policy is that the minimum host         
  910. access rate be 9.6 kb/s.
  911. DCAC-350-180-( )                                                     2-3
  912.  
  913.  
  914.  
  915.      +--------------------------------------------------------------+
  916.      |                                                              |
  917.      |                                                              |
  918.      | C/30E PSN                                         Host       |
  919.      | +-----------+   +-----------+ +-----------+    +-----------+ |
  920.      | |           |   |           | |           |A   |           | |
  921.      | |118-114 Bal|---|188-114 Bal|-|188-114 Bal|----|118-114 Bal| |
  922.      | |   DTE     |   |   DCE     | |   DCE     |    |   DTE     | |
  923.      | |           |   |           | +           |    |           | |
  924.      | +-----------+   +-----------+ +-----------+    +-----------+ |
  925.      |                                                              |
  926.      |                                                              |
  927.      |                                                              |
  928.      +--------------------------------------------------------------+
  929.  
  930.     FIGURE 2-1.  DEMERCATION POINT "A" BETWEEN THE C/30 AND REMOTE HOST
  931.  
  932.  
  933.  
  934.    +-------------------------------------------------------------------+
  935.    |   C/30E PSN                                              Host     |
  936.    | +-----------+                                       +-----------+ |
  937.    | |118-114 Bal|                                       |           | |
  938.    | |   DTE     |                                       |118-114 Bal| |
  939.    | |           |                                       |   DTE     | |
  940.    | |           |                                       |           | |
  941.    | +-----+-----+                                       +-----+-----+ |
  942.    |       |                                                   |       |
  943.    |       |                                                   |       |
  944.    |   +---+---+                                           +---+---+   |
  945.    |   | DPPE  |                                           | DPPE  |   |
  946.    |   +---+---+                                           +---+---+   |
  947.    |       |                                                   |       |
  948.    |       |                                                   |       |
  949.    |       |      +--+ +-----------+ +-----------+  +---+      |B      |
  950.    |   +---+---+  |D | |           | |           |  |D  |  +---+---+   |
  951.    |   | KGAB  |--|P |-|188-114 Bal|-|188-114 Bal|--|P  |--| KGAB  |   |
  952.    |   |       |  |P | |           | |   DCE     |  |P  |  |       |   |
  953.    |   +-------+  |C | |           | |           |  |C  |  +-------+   |
  954.    |              +--+ +-----------+ +-----------+  +---+              |
  955.    |                                                                   |
  956.    |                                                                   |
  957.    +-------------------------------------------------------------------+
  958.  
  959.        FIGURE 2-2.  DEMARCATION POINT "B" BETWEEN THE KGAB AND HOST
  960.  
  961. DCAC-350-180-( )                                                     2-4
  962.  
  963.  
  964.         (2)  Signaling Sense.  Signaling sense for balanced and       
  965. unbalanced circuits is in accordance with EIA-422-A with the exception     
  966. of the differential voltage, which applied to the interconnecting         
  967. cable, is in the C/30E range of 2 volts to 9 volts.  As defined in     
  968. RS-232-A, ON (0, Space, or +) is generated when the A terminal is       
  969. positive with respect to the B terminal, and OFF (1, MARK, or -) is    
  970. generated when the A terminal is negative with respect to the B terminal.
  971.  
  972.     c.  Bit Rate and Cable Length.
  973.  
  974.         (1)  EIA-449 Compliance.  Interconnecting cable length and its   
  975. relation to data signaling rates is in accordance with EIA Standard 449, 
  976. section 6.10, and EIA Standard 422-A, section 4.3 and the appendix.
  977.  
  978.         (2)  Maximum Cable Length.  The maximum cable length between the   
  979. remote modem and the host including the intervening FPA is 1000 feet;   
  980. however, cable lengths less than 200 feet are preferred.
  981.  
  982.     d.  Interchange Circuits.
  983.  
  984.         (1)  C/30E Local Modem Interface.
  985.  
  986.              (a)  Signal flow between the C/30E and the local modem is     
  987. shown in figure 2-3.  This interface and associated hardware are        
  988. provided by DDN.  The signal flow is the same when a KG-84A is used.       
  989. This interface uses EIA-449 pin assignments.
  990. DCAC-350-180-( )                                                     2-5
  991.  
  992.  
  993.              (b)  As shown in figure 2-3, the supported signals are        
  994. Send Data (SD), Send Timing (ST), Receive Data (RD), Receive Timing (RT),  
  995. and Terminal Ready (TR).  Clear to Send (CS), Data Mode (DM), and       
  996. Receiver Ready (RR) are tied ON by the cable connected to the fantail.    
  997. Remote Loopback (RL) and Local Loopback (LL) are to be used for those  
  998. functions and they are connected at the DCE interface.   Terminal Timing   
  999. (TT) is not supported from the PSN.
  1000.  
  1001.              (c)  Two special DDN-specific loopback signals, CL and DL,    
  1002. are provided as shown in figure 2-3.  The Signaling Rate Selector (SR)    
  1003. signal is used by the PSN to loop the local KG-84A and is designated as    
  1004. "C" loop or CL (standing for COMSEC Loopback) in figure 2-3 after it      
  1005. leaves the C/30E fantail.  SR is not connected to the DCE interface.  The 
  1006. Request To Send (RS) signal is reserved for future use within the FPA     
  1007. KG-84A and  is designated as "D" loop or DL.  RS is not connected at the   
  1008. DCE interface.  The Terminal Ready (TR) signal from the PSN provides 
  1009. both    the Terminal Ready and Request to Send (RS) to the DCE.
  1010.  
  1011.         (2)  Host-Remote Modem Interface.  The cable functional signal    
  1012. flow between the remote modem and the DTE host is also shown in figure     
  1013. 2-3.  The signal flow is the same as that described in 1.d.1, above.      
  1014. The KGAB uses MS connectors with the pinout shown in figure 2-3 and       
  1015. tables 2-2 and 2-3.  Figure 2-3 shows DDN standard cables.  Figure 2-2     
  1016. is provided as an example of one way to connect to a remote host.  If      
  1017. DDN standard cables are not used, only the signals shown as mandatory      
  1018. in table 2-2 are required.  The optional signals are used by the PSN end   
  1019. of the circuit.
  1020. DCAC-350-180-( )                                                     2-6
  1021.  
  1022.  
  1023. 3.  Mechanical Characteristics.  All EIA-449/422 connectors offered for    
  1024. the C/30E meet the specifications provided in this section.
  1025.  
  1026.     a.  Interface Connectors.  DDN MIL-STD-188-114 DCE connectors are     
  1027. DC-37S type (female) connectors.  The DDN FPA uses an MS connector on      
  1028. the KGAB counter assemblies.
  1029.  
  1030.     b.  Connector Contact Assignments.
  1031.  
  1032.         (1)  C/30E Connectors.  All DDN EIA-449/422 contact assignments    
  1033. are in accordance with EIA-449, section 3.4.  In chapter 1, table 1-5   
  1034. provides the standard DTE pinouts and section 2.d.3 provides circuit 
  1035. descriptions.
  1036.  
  1037.         (2)  KGAB Connectors.  KGAB connectors to the remote host and the 
  1038. remote modem are shown in tables 2-2 and 2-3, respectively.
  1039. DCAC-350-180-( )                                                     2-7
  1040.  
  1041.  
  1042.  
  1043.  PSN/                  Patch                                        Patch                DCE
  1044.  Host        Cable #   Panel   Cable #         KGAB       Cable #   Panel   Cable #       
  1045.              6847              6817                       6812              7835         
  1046.                        Pin #                                        Pin #                 
  1047.  +--+ Pin #  +-----+  +-----+ +-----+   Pin #  +--+  Pin #  +----+ +-----+ +----+  Pin # +--+
  1048.  |  |  +/-   |     |  | +/- | |     |    +/-   |  |   +/-   |    | | +/- | |    |   +/-  |  |
  1049.  |SD|  4/22 --------->| 2/14|---(1)---> 24/25  |SD|  2/3  -------->| 2/14|--------> 4/22 |SD|
  1050.  |  |                 |     |                  |  |                |     |               |  |
  1051.  |ST|  5/23 --------->|15/16|<--(2)----  4/5   |ST|  4/5  <--------|15/16|<-------- 5/23 |ST|
  1052.  |  |                 |     |                  |  |                |     |               |  |
  1053.  |RD|  6/24 --------->| 3/19|<--(3)----  6/7   |RD|  6/7  <--------| 3/19|<-------- 6/24 |RD|
  1054.  |  |                 |     |                  |  |                |     |               |  |
  1055.  |RT|  8/26 --------->|17/18|<--(4)----  8/9   |RT|  8/9  <--------|17/18|<-------- 8/26 |RT|
  1056.  |  |                 |     |                  |  |                |     |               |  |
  1057.  |TR| 12/30 --------->|20/10|---(5)---> 10/11  |TR| 10/11  ------->|20/10|----+--->12/30 |TR|
  1058.  |  |                 |     |                  |  |                |     |    |          |  |
  1059.  |  |                 |     |                  |  |                |     |    +---> 7/25 |RS|
  1060.  |  |                 |     |                  |  |                |     |               |  |
  1061.  |  |       NC<-------| 5/6 |<--(6)---- 14/15  |CS| 12/13  <-------| 5/6 |<-------- 9/27 |CS|
  1062.  |  |                 |     |                  |  |                |     |               |  |
  1063.  |SG| 19/37 ------+---| 7/8 |---(7)---> 12/13  |SG| 14/15  --------| 7/8 |--------- 19/37|SG|
  1064.  |  |             |   |     |                  |  |                |     |               |  |
  1065.  |SR| 16/37 ------|-->|12/13|---(8)---> 16/17  |CL| 16/17  ------->|12/13|------> NC     |  |
  1066.  |  |             |   |     |                  |  |                |     |               |  |
  1067.  |RL| 14/37 ------|-->|11/21|---(9)---> 18/19  |RL| 18/19  ------->|11/21|-------->14/37 |RL|
  1068.  |  |             |   |     |                  |  |                |     |               |  |
  1069.  |RS|  7/37 ------|-->| 4/9 |---(10)--> 20/21  |DL| 20/21  ------->| 4/9 |------> NC     |  |
  1070.  |  |             |   |     |                  |  |                |     |               |  |
  1071.  |LL| 10/37 ------|-->|22/25|---(11)--> 22/23  |LL| 22/23  ------->|22/25|-------->10/37 |LL|
  1072.  |  |             |   |     |                  |  |                |     |               |  |
  1073.  |ON| 28/32 --->+ +-->|24/23|---(12)-->  2/3   |TT| 24/25  ------->|24/23|-------->17/35 |TT|
  1074.  |CS|  9/27 <---|     +-----+                  +--+                +-----+               |  |
  1075.  |DM| 11/29 <---|                                                                        |  |
  1076.  |RR| 13/31 <---|                                                                        |  |
  1077.  +--+                                                                                    +--+
  1078.  
  1079.     Notes:  1.  Pin numbers are the same on both sides of Patch Panel.
  1080.             2.  Encircled numbers are the cable pair numbers.
  1081.  
  1082.       FIGURE 2-3.  FUNCTIONAL SIGNAL FLOW BETWEEN A NEARBY MODEM AND
  1083.                    C/30E OR A KGAB AND A REMOTE HOST
  1084.  
  1085. DCAC-350-180-( )                                                     2-8
  1086.  
  1087.  
  1088.           TABLE 2-1.  REMOTE-MODEM DTE INTERFACE CONNECTOR PINOUT
  1089.  
  1090.                                                                            
  1091.  
  1092.         Pin     EIA     CCITT     Name                    
  1093.                 ID      ID                           
  1094.  
  1095. Mandatory
  1096.  
  1097.         1       FG                 Frame Ground      
  1098.         4       SD +    103        Send Data         
  1099.         22      SD -    103        Send Data         
  1100.         5       ST +    114        Send Timing       
  1101.         23      ST -    114        Send Timing       
  1102.         6       RD +    104        Receive Data      
  1103.         24      RD -    104        Receive Data      
  1104.         7       RS +    105        Request to Send        
  1105.         25      RS -    105        Request to Send
  1106.         8       RT +    115        Receive Timing         
  1107.         26      RT -    115        Receive Timing
  1108.         9       CS +    106        Clear to Send
  1109.         27      CS -    106        Clear to Send
  1110.         12      TR +    108.2      Terminal Ready         
  1111.         30      TR -    108.2      Terminal Ready
  1112.         17      TT +    113        Terminal Timing        
  1113.         35      TT -    113        Terminal Timing
  1114.         19      SG      102        Signal Ground          
  1115.         37      SC      102a       Send Common
  1116.  
  1117. Optional
  1118.  
  1119.         2       SI      112        Signaling Rate Indicator
  1120.         10      LL      141        Local Loopback
  1121.         11      DM +    107        Data Mode
  1122.         13      RR      109        Receiver Ready
  1123.         14      RL      140        Remote Loopback
  1124.         15      IC      125        Incoming Call
  1125.         16      SF/SR   126/111    Select Frequency/Signaling Rate Selector 
  1126.         18      TM      142        Test Mode
  1127.         20      RC      102b       Receive Common
  1128.         28      IS      ---        Terminal In Service
  1129.         29      DM -    107        Data Mode
  1130.         31      RR -    109        Receiver Ready
  1131.         32      SS      116        Select Standby
  1132.         33      SQ      110        Signal Quality
  1133.         34      NS      ---        New Signal
  1134.         36      SB      117        Standby Indicator
  1135.                                                                  
  1136.                                                                            
  1137.  
  1138. DCAC-350-180-( )                                                     2-9
  1139.  
  1140.  
  1141.               TABLE 2-2.  KGAB - REMOTE HOST CONNECTOR PINOUT
  1142.                                                                  
  1143.                                                                            
  1144.  
  1145.         Pin     EIA     CCITT      Name
  1146.                 ID      ID            
  1147.  
  1148. Mandatory
  1149.  
  1150.         1       FG                    Frame Ground           
  1151.         24      SD +    103           Send Data              
  1152.         25      SD -    103           Send Data
  1153.         4       ST +    114           Send Timing
  1154.         5       ST -    114           Send Timing
  1155.         6       RD +    104           Receive Data           
  1156.         7       RD -    104           Receive Data
  1157.         8       RT +    115           Receive Timing         
  1158.         9       RT -    115           Receive Timing
  1159.         10      TR +    108.2         Terminal Ready         
  1160.         11      TR -    108.2         Terminal Ready
  1161.         12      SG      102           Signal Ground          
  1162.         13      SC      102a          Send Common            
  1163.         19      SS      116           Select Standby
  1164.  
  1165. Optional
  1166.  
  1167.         14      CS +    106           Clear to Send
  1168.         15      CS -    106           Clear to Send
  1169.         22      LL      141           Local Loopback
  1170.         20      DL +    105           "D" Loop (Reserved)    
  1171.         21      DL -    105           "D" Loop (Reserved)
  1172.         18      RL      140           Remote Loopback
  1173.         2       TT +    113           Terminal Timing        
  1174.         3       TT -    113           Terminal Timing
  1175.         16      CL +    126           "C" Loop (KG-84A Loop)
  1176.         17      CL -    126           "C" Loop (KG-84A Loop)
  1177.                                                                  
  1178.                                                                            
  1179.  
  1180.  
  1181. DCAC-350-180-( )                                                     2-10
  1182.  
  1183.  
  1184.               TABLE 2-3  KGAB - REMOTE MODEM CONNECTOR PINOUT
  1185.  
  1186.                                                                            
  1187.  
  1188.         Pin     EIA     CCITT     Name
  1189.                 ID      ID         
  1190.  
  1191. Mandatory
  1192.  
  1193.  
  1194.         1       FG                 Frame Ground
  1195.         2       SD +    103        Send Data
  1196.         3       SD -    103        Send Data
  1197.         4       ST +    114        Send Timing
  1198.         5       ST -    114        Send Timing
  1199.         6       RD +    104        Receive Data
  1200.         7       RD -    104        Receive Data
  1201.         8       RT +    115        Receive Timing
  1202.         9       RT -    115        Receive Timing
  1203.         10      TR +    108.2      Terminal Ready
  1204.         11      TR -    108.2      Terminal Ready
  1205.         14      SG      102        Signal Ground
  1206.         15      SG      102        Signal Ground
  1207.         24      TT +    113        Terminal Timing
  1208.         25      TT -    113        Terminal Timing
  1209.  
  1210. Optional
  1211.  
  1212.         12      CS +    106        Clear To Send
  1213.         13      CS -    106        Clear To Send
  1214.         16      CL      ---        "C" Loop (KG-84A Loop)
  1215.         17      CL -    ---        "C" Loop (KG-84A Loop)
  1216.         18      RL +    140        Remote Loopback
  1217.         19      RL -    140        Remote Loopback
  1218.         20      DL +    ---        "D" Loop (Reserved)
  1219.         21      DL -    ---        "D" Loop (Reserved)
  1220.         22      LL +    141        Local Loopback
  1221.         23      LL -    141        Local Loopback
  1222.                                                                  
  1223.                                                                            
  1224. DCAC-350-180-( )                                                     2-11
  1225.  
  1226.  
  1227. 4.  Interconnecting Cables.  Figures 2-4 and 2-5 provide a cabling       
  1228. diagram of a configuration with a C/30E, modems, and FPAs.  Table 2-4  
  1229. describes the cables used for interconnecting these devices.  See        
  1230. chapter 1, section 4, for specifications on interconnecting cables.
  1231.  
  1232.  
  1233.                      TABLE 2-4. REMOTE INTERFACE CABLES
  1234.                                   
  1235.                                                                            
  1236.  
  1237. Connection         BBNCC           Description
  1238.                    P/N#
  1239.  
  1240. PSN/Host to DPPE   2406847GO1      12-pr, PSN/MSYNC 188-114
  1241.                                     Bal Host to DB25P
  1242.  
  1243. DPPE to KGAB       2406817GO1      12-pr, DB25S to FPA-J1
  1244.  
  1245. KGAB to DPPC       2406812GO1      12-pr, FPA-J2 to DB25P
  1246.  
  1247. DPPC to DCE        2407835GO1      12-pr, DB25S to 188-114 DCE
  1248.                                   
  1249.                                                                            
  1250. DCAC-350-180-( )                                                     2-12
  1251.  
  1252.  
  1253.  
  1254.    +------------------------------------------------------------------------+
  1255.    |                                                                        |
  1256.    |                                                                        |
  1257.    |                                                                        |
  1258.    |         Cable # +-+ Cable #                 Cable # +-+  Cable #       |
  1259.    | +-----+2406847- | |2407835-                 2407835-| | 240687-        |
  1260.    | |C/30E|   G01   |D|  G01   +-----+   +-----+  G01   |D|   G01   +----+ |
  1261.    | | PSN |---------|P|--------| DCE |---| DCE |--------|P|---------|DTE | |
  1262.    | |(DTE)|         |P|        +-----+   +-----+        |P|         |HOST| |
  1263.    | +-----+         |E|                                 |E|         +----+ |
  1264.    |                 +-+                                 +-+                |
  1265.    |                                                                        |
  1266.    |                                                                        |
  1267.    |                                                                        |
  1268.    |                                                                        |
  1269.    +------------------------------------------------------------------------+
  1270.  
  1271.                FIGURE 2-4.  C/30E AND REMOTE HOST CABLING DIAGRAM
  1272.  
  1273.  
  1274.  
  1275.  
  1276.    +------------------------------------------------------------------------+
  1277.    |                                                                        |
  1278.    | +-----+                                                        +-----+ |
  1279.    | |C/30E|                                                        | DTE | |
  1280.    | | PSN |                                                        | HOST| |
  1281.    | |(DTE)|                                                        |     | |
  1282.    | +--+--+                                                        +--+--+ |
  1283.    |    | Cable #                                              Cable # |    |
  1284.    |    | 2406847G01                                        2406847G01 |    |
  1285.    | +--+--+                                                        +--+--+ |
  1286.    | | DPPE|                                                        | DPPE| |
  1287.    | +--+--+                                                        +--+--+ |
  1288.    |    | Cable #                                              Cable # |    |
  1289.    |    | 2406817G01                                        2406817G01 |    |
  1290.    |    |                                                              |    |
  1291.    |    |   Cable #      Cable #                 Cable #     Cable #   |    |
  1292.    | +--+--+2406812-+-+ 2407835-                2407835- +-+2406812-+--+--+ |
  1293.    | |     |  G01   |D|   G01  +-----+    +-----+  G01   |D|  G01   |     | |
  1294.    | | KGAB|--------|P|--------| DCE |----| DCE |--------|P|--------| KGAB| |
  1295.    | |     |        |P|        +-----+    +-----+        |P|        |     | |
  1296.    | +-----+        |C|                                  |C|        +-----+ |
  1297.    |                +-+                                  +-+                |
  1298.    |                                                                        |
  1299.    |                                                                        |
  1300.    +------------------------------------------------------------------------+
  1301.  
  1302.                FIGURE 2-5.  C/30E AND REMOTE HOST CABLING DIAGRAM
  1303.                             (WITH CRYPTOGRAPHIC DEVICES)
  1304.  
  1305. DCAC-350-180-( )                                                 3-1
  1306.  
  1307.                     CHAPTER 3.  EIA-232-D HOST INTERFACE
  1308.  
  1309. 1.  Overview.  This chapter describes the electrical and mechanical 
  1310. characteristics of the obsolete DDN EIA-232-D connection at the neighbor  
  1311. or nearby host.  For ease of reference, table 3-1 equates the EIA-232-D, 
  1312. EIA-449, and CCITT interface signal names.  However, in the rest of this 
  1313. chapter, only the EIA-232-D signal name will be used.  DDN uses the    
  1314. EIA-232-D interface only where an existing non-DDN standard PSN provides   
  1315. such an interface, and it is not feasible to install a MIL-STD-188-114  
  1316. balanced interface prior to upgrading the entire node to DDN standard 
  1317. (MIL-STD-188-114 balanced serial host interfaces).
  1318.  
  1319. 2.  Electrical Characteristics.
  1320.  
  1321.     a.  Voltage Levels.  The electrical measurements of the C/30E      
  1322. EIA-232-D interface circuits are in accordance with EIA Standard 232-D,  
  1323. section 2.1.  For normal operation, the open circuit driver voltage shall  
  1324. be no more than +15 V.
  1325.  
  1326.     b.  Clocking.
  1327.  
  1328.         (1)  Supported Clock Rates.  The FD4 fantail contains the     
  1329. connectors that terminate cables from all I/O interfaces.  The FD4 
  1330. DCAC-350-180-( )                                                 3-2
  1331.  
  1332. fantail contains four EIA-232-D connectors configured as DTEs.  This   
  1333. interface has clock-sourcing capability allowing either the DTE or DCE     
  1334. to provide the clock.  The hardware can support external clock rates     
  1335. between 1.2 kb/s and 112 kb/s.  However, DDN policy is 9.6 kb/s for the  
  1336. minimum PSN host bit rate, and 19.2 kb/s for the maximum rate.
  1337.  
  1338.         (2)  Signaling Sense.  Signaling sense is in accordance with EIA 
  1339. Standard 232-D, subsection 2.1.3.  The signal is considered marking (OFF)  
  1340. when the voltage on the interchange circuit is more negative than -3 V     
  1341. with respect to signal ground, and spacing (ON) when the voltage is more 
  1342. positive than +3 V with respect to signal ground.
  1343.  
  1344.     c.  Bit Rate and Cable Length.  Interconnecting cable length is in 
  1345. accordance with EIA-232-D, section 3.1.  The recommended maximum cable    
  1346. length between an EIA-232-D DCE and DTE is 200 feet when overall       
  1347. shielded, low capacitance, twisted pair cable is used.
  1348.  
  1349.     d.  Interchange Circuits.
  1350.  
  1351.         (1)  Electrical Use of Interchange Circuits.  The DDN electrical   
  1352. use of interchange circuits is either static or active.  Static circuits   
  1353. are tied by the hardware so that the signal state remains constant on the  
  1354. line, either ON or OFF.  Active circuits change their state under program 
  1355. control.  DDN use of the interchange circuits is shown in table 3-2.
  1356.  
  1357. DCAC-350-180-( )                                                 3-3
  1358.  
  1359.                  TABLE 3-1.  SIGNAL NAME EQUIVALENCY TABLE
  1360.  
  1361.                                                                           
  1362.  
  1363.  
  1364.      EIA-232-D                                      EIA-449                        CCITT
  1365.      ID     Name                                    ID     Name                    ID     Name
  1366.              
  1367.      AB     Signal Ground                           SG     Signal Ground           102    Signal Ground
  1368.      CE     Ring Indicator                          IC     Incoming Call           125    Calling Indicator
  1369.      CD     DTE Ready                               TR     Terminal Ready          108/2  Data Terminal Ready
  1370.      CC     DCE Ready                               DM     Data Mode               107    Data Set Ready
  1371.      BA     Transmitted Data                        SD     Send Data               103    Transmitted Data
  1372.      BB     Received Data                           RD     Receive Data            104    Received Data
  1373.      DA     Transmitter Signal Element Timing       TT     Terminal Timing         113    Transmitter Signal Element
  1374.              (DTE Source)                                                                  Timing (DTE Source)
  1375.      DB     Transmitter Signal Element Timing       ST     Send Timing             114    Transmitter Signal Element
  1376.              (DCE Source)                                                                  Timing (DCE Source)
  1377.      DD     Receiver Signal Element Timing          RT     Receive Timing          115    Receiver Signal Element
  1378.              (DCE Source)                                                                  Timing (DCE Source)
  1379.      CA     Request To Send                         RS     Request To Send         105    Request To Send
  1380.      CB     Clear To Send                           CS     Clear To Send           106    Ready For Sending
  1381.      CF     Received Line Signal Detector           RR     Receiver Ready          109    Data Channel Received Line
  1382.                                                                                            Signal Detector
  1383.      CG     Signal Quality Detector                 SQ     Signal Quality          110    Data Signal Quality
  1384.                                                                                            Detector
  1385.      CH     Data Signal Rate Selector               SR     Signaling Rate Selector 111    Data Signaling Rate
  1386.              (DTE Source)                                                                  Selector (DTE Source)
  1387.      CI     Data Signal Rate Selector               SI     Signaling Rate          112    Data Signaling Rate
  1388.              (DCE Source)                                   Indicator                      Selector (DCE Source)
  1389.      LL     Local Loopback                          LL     Local Loopback          141    Local Loopback
  1390.      RL     Remote Loopback                         RL     Remote Loopback         140    Remote Loopback
  1391.      TM     Test Mode                               TM     Test Mode               142    Test Indicator
  1392.     
  1393.  
  1394.                                                                           
  1395. DCAC-350-180-( )                                                 3-4
  1396.  
  1397.         (2)  Software Use of Interchange Circuits.  Interchange circuit  
  1398. signals are used by the software in different ways.  Active circuits are   
  1399. under program control: either the software reacts to the circuit signal    
  1400. when it changes, or the software can assert a circuit when necessary       
  1401. (such as LL which can be used by operations personnel for testing 
  1402. connections).  Unsupported circuits either are not read by the software    
  1403. or a value is written to the circuit by the software, and that value does  
  1404. not change during operation.  Table 3-2 provides a list of circuits and    
  1405. their use.
  1406.  
  1407.         (3)  Interchange Circuit Definitions.
  1408.  
  1409.              (a)  Signal Ground.  See EIA Standard 232-D.
  1410.  
  1411.              (b)  Ring Indicator.  RI is reported to the Monitoring      
  1412. Center; however, its value has no software effect.
  1413.  
  1414.              (c)  DCE Ready.  This circuit must be asserted ON by the      
  1415. DCE, and it is monitored by the PSN software.
  1416.  
  1417.              (d)  DTE Ready.  This circuit is asserted ON by PSN 
  1418. software   when the link is initialized.
  1419.  
  1420.              (e)  Transmitted Data.  See EIA Standard 232-D.
  1421.  
  1422.              (f)  Received Data.  See EIA Standard 232-D.
  1423. DCAC-350-180-( )                                                 3-5
  1424.  
  1425.              (g)  Transmitter Signal Element Timing (DTE Source).  See EIA 
  1426. Standard 232-D.  Also see subsection 2.b of this guide.  This circuit 
  1427. provides the clock for Transmitted Data when the PSN sources timing.  The 
  1428. frequency of this circuit should be equal to that of DTE-Sourced Receiver 
  1429. Signal Element Timing.
  1430.  
  1431.              (h)  Transmitter Signal Element Timing (DCE Source).  See EIA 
  1432. Standard 232-D.  This circuit provides the clock for Transmitted Data when 
  1433. the clock for Transmitted Data when the DCE sources timing.
  1434.  
  1435.              (i)  Receiver Signal Element Timing (DTE Source).  This 
  1436. circuit provides the clock for Received Data when the PSN sources timing.  
  1437. The frequency of this circuit should be equal to that of DTE-Sourced 
  1438. Transmitter Signal Element Timing.
  1439.  
  1440.              (j)  Receiver Signal Element Timing (DCE Source).  See EIA 
  1441. Standard 232-D.  This circuit provides clock for Received Data when the 
  1442. DCE sources timing.
  1443.  
  1444.              (k)  Request to Send.  This circuit is asserted ON by PSN 
  1445. software when the link is initialized.
  1446.  
  1447.              (l)  Clear to Send.  CS must be asserted ON by the DCE 
  1448. because it is monitored to determine line status.  If the signal state on 
  1449. this line changes to OFF, the software macrocode will stop data 
  1450. transmission.
  1451. DCAC-350-180-( )                                                 3-6
  1452.  
  1453.              (m)  Received Line Signal Detector.  This circuit must be 
  1454. asserted ON by the DCE because it is monitored to determine line status.  
  1455. If the signal state on this line changes to OFF, the software macrocode 
  1456. will stop receiving data.
  1457.  
  1458.              (n)  Signal Quality Detector.  This circuit is reported to 
  1459. the Monitoring Center; however, its value has no software effect.
  1460.  
  1461.              (o)  Data Signal Rate Selector (DTE Source).  This circuit is 
  1462. asserted OFF by the PSN software when the link is initialized.
  1463.  
  1464.              (p)  Data Signal Rate Selector (DCE Source).  This circuit is 
  1465. electrically active; however, its value has no software effect.
  1466.  
  1467.              (q)  Local Loopback.  LL is electrically active, but asserted 
  1468. OFF by PSN software when the link is initialized.  LL can be controlled by 
  1469. the Monitoring Center.
  1470.  
  1471.              (r)  Remote Loopback.  RL is electrically active, but 
  1472. asserted OFF by PSN software when the link is initialized.  This circuit 
  1473. is available for Monitoring Center control.
  1474.  
  1475.              (s)  Test Mode.  TM is reported to the Monitoring Center; 
  1476. however, its value has no software effect.
  1477.  
  1478. DCAC-350-180-( )                                                 3-7
  1479.  
  1480.                TABLE 3-2. EIA-232-D INTERCHANGE CIRCUIT USE
  1481.  
  1482.                                                                           
  1483.  
  1484.  
  1485. 232                                               Electrical       Required State of             Comments
  1486. ID     EIA-232-D Name             Source          State         Control/Status Signals
  1487.  
  1488. AB     Signal Ground              DTE/DCE         Ground                 N/A*          
  1489. BA     Transmitted Data           DTE             Active                 N/A           Data Circuit
  1490. BB     Received Data              DCE             Active                 N/A           Data Circuit
  1491. CA     Request to Send            DTE             Active                 ON            Asserted ON by PSN software.
  1492. CB     Clear to Send              DCE             Active                 ON            Asserted ON by DCE, and
  1493.                                                                                        monitored by PSN software to 
  1494.                                                                                        determine line status.
  1495. CD     DTE Ready                  DTE             Active                 ON            Asserted ON by PSN software.
  1496. CF     Received Line Signal       DCE             Active                 ON            Asserted ON by DCE, and
  1497.         Detector                                                                       monitored by PSN software to
  1498.                                                                                        determine line status.
  1499. CG     Signal Quality             DCE             Active                 Don't Care    Monitored by PSN software, but
  1500.         Detector                                                                       no action is taken.
  1501. CH     Data Signal Rate           DTE             Active                 OFF           Asserted OFF by PSN software.
  1502.        Selector
  1503. CI     Data Signal Rate           DCE             Active                 Don't Care    Not monitored by PSN software.
  1504.         Selector                                                                       
  1505. DA     Transmitter Signal         DTE             Active                 N/A           Timing circuit for Transmitted
  1506.         Element Timing                                                                 Data when the PSN supplies
  1507.                                                                                        timing.
  1508. DB     Transmitter Signal         DCE             Active                 N/A           Timing circuit for Transmitted
  1509.         Element Timing                                                                 Data when the DCE supplies
  1510.                                                                                        timing.
  1511. DC**   Receive Signal             DTE             Active                 N/A           Timing circuit used for
  1512.         Element Timing                                                                 Received Data when the PSN
  1513.                                                                                        supplies timing.
  1514. DD     Receive Signal             DCE             Active                 N/A           Timing circuit used for
  1515.         Element Timing                                                                 Received Data when the DCE
  1516.                                                                                        supplies timing.
  1517. CE     Ring Indicator             DCE             Active                 Don't Care    Monitored by PSN software, but
  1518.                                                                                        no action is taken.
  1519. LL     Local Loopback             DTE             Active                 OFF           Initialized to OFF by
  1520.                                                                                        software.  Available for
  1521.                                                                                        Monitoring Center control.
  1522. RL     Remote Loopback            DTE             Active                 OFF           Initialized to OFF by
  1523.                                                                                        software.  Available for
  1524.                                                                                        Monitoring Center control.
  1525. TM     Test Mode                  DCE             Active                 Don't Care    Monitored by PSN software, but
  1526.                                                                                        no action is taken.
  1527.  
  1528.  
  1529.                                                                           
  1530.  
  1531. * N/A = Not Applicable
  1532. ** The circuit name "DC" is from an earlier version of EIA-232.
  1533. DCAC-350-180-( )                                                 3-8
  1534.  
  1535. 3.  Mechanical Characteristics.  All EIA-232-D connectors on the C/30E 
  1536. meet the specifications provided in this section.
  1537.  
  1538.     a.  Interface Connectors.    All C/30E fantail MSYNC EIA-232-D 
  1539. connectors are DB-25P type (male) connectors.  Intermating dimensions are 
  1540. in accordance with EIA-232-D, section 3.2.1.
  1541.  
  1542.     b.  Connector Contact Assignments.  DDN standard node EIA-232-D 
  1543. connector contact assignments are in accordance with EIA-232-D, section 
  1544. 3.3.1.  Table 3-3 provides DDN EIA-232-D connector pin assignments.  
  1545. Signal use is specified in section 2.d.3.
  1546.  
  1547. DCAC-350-180-( )                                                 3-9
  1548.  
  1549.                    TABLE 3-3.  EIA-232-D CONNECTOR PINOUT
  1550.                                                                  
  1551.                                                                           
  1552.  
  1553. Pin     EIA     CCITT         Name
  1554.         ID      ID            
  1555.  
  1556. 1       --      --            Shield
  1557. 2       BA      103           Transmitted Data
  1558. 3       BB      104           Received Data
  1559. 4       CA      105           Request To Send
  1560. 5       CB      106           Clear To Send
  1561. 6       CC      107           DCE Ready
  1562. 7       AB      102           Signal Ground (Common Return)
  1563. 8       CF      109           Received Line Signal Detector
  1564. 11      --      126           Select Transmit Frequency
  1565. 15      DB      114           Transmitted Signal Element Timing
  1566.                                (DCE Source)
  1567. 17      DD      115           Receiver Signal Element Timing
  1568.                                (DCE Source)
  1569. 18      LL      141           Local Loopback
  1570. 19      DC*     ---           Receiver Signal Element Timing
  1571.                                (DTE Source)
  1572. 20      CD      108/2         DTE Ready
  1573. 21      CG      110           Signal Quality Detector
  1574. 22      CE      125           Ring Indicator
  1575. 23      CH/CI   111/112       Data Rate Selector
  1576. 24      DA      113           Transmit Signal Element Timing
  1577.                                (DTE Source)
  1578. 25      --      142           Test Indicator
  1579.  
  1580.                                                                           
  1581.  
  1582. * The circuit name "DC" is from an earlier version of EIA-232.
  1583.  
  1584. DCAC-350-180-( )                                                 3-10
  1585.  
  1586. 4.  Interconnecting Cables.
  1587.  
  1588.     a.  For interconnecting cable specifications, see chapter 1, section 
  1589. 4, of this guide.
  1590.  
  1591.     b.  Figure 3-1 is a cabling diagram of a C/30E PSN connected to a 
  1592. nearby EIA-232 host, and figure 3-2 is an example of an interconnecting 
  1593. cable (BBNCC P/N# 2409318G01).
  1594.  
  1595.  
  1596.  
  1597.  
  1598.  
  1599.  
  1600.      +---------------------------------------------------------------+
  1601.      |                                                               |
  1602.      |               DB-25S                    DB-25S                |
  1603.      |                 /                           \                 |
  1604.      | +----------+  /                               \  +----------+ |
  1605.      | | EIA-232  |--+            2409318G01         +--| EIA-232  | |
  1606.      | | DTE Host |P1|===============================|P2|  C/30E   | |
  1607.      | |          |--+                               +--|  (DTE)   | |
  1608.      | +----------+                                     +----------+ |
  1609.      |                                                               |
  1610.      |                                                               |
  1611.      |                                                               |
  1612.      |                                                               |
  1613.      +---------------------------------------------------------------+
  1614.  
  1615.       FIGURE 3-1.  C/30 PSN AND NEARBY EIA-232-D HOST CABLING DIAGRAM
  1616.  
  1617. DCAC-350-180-( )                                                 3-11
  1618.  
  1619.  
  1620.        +-----------------------------------------------------------+
  1621.        |     DTE Host                                    C/30E     |
  1622.        |        P1                                         P2      |
  1623.        |      DC-37S                                     DC-37S    |
  1624.        | Pin#     Signal                            Signal    Pin# |
  1625.        |  +/-       +/-   Shield             Shield   +/-      +/- |
  1626.        |  1         FG  >--------+         +-------<  FG       1   |
  1627.        |                                                           |
  1628.        |                 Pair #                                    |
  1629.        |  2/7       SD  >-(1)------\   /-----------<  SD       2/7 |
  1630.        |                             \                             |
  1631.        |  15/NC     ST  >-(2)---\  /   \ /---------<  TT      24/7 |
  1632.        |                         /     / \                         |
  1633.        |  3/NC      RD  >-(3)--/   \ /     \-------<  RD      3/NC |
  1634.        |                           / \                             |
  1635.        |  17/NC     RT  >-(4)----/     \-----------<  TRT     19/7 |
  1636.        |                                                           |
  1637.        |  4/7       RS  >-(5)-----------\   /------<  RS       4/7 |
  1638.        |                                  \                        |
  1639.        |  6/NC      DM  >-(6)--+--------/   \--+---<  DM      6/NC |
  1640.        |                       |               |                   |
  1641.        |  5/NC      CS  >------+               +---<  CS      5/NC |
  1642.        |                       |               |                   |
  1643.        |  8/NC      RR  >------+               +---<  RR      8/NC |
  1644.        |                                                           |
  1645.        |  7/7       SG  >-(7)-+--------------------<  SG       7/7 |
  1646.        |                      |                                    |
  1647.        |                      +--(8)----No Connection (NC)         |
  1648.        |                      |                                    |
  1649.        |                      +--(9)----NC                         |
  1650.        |                      |                                    |
  1651.        |                      +--(10)---NC                         |
  1652.        |                      |                                    |
  1653.        |                      +--(11)---NC                         |
  1654.        |                      |                                    |
  1655.        |                      +--(12)---NC                         |
  1656.        |                      |                                    |
  1657.        |                      +--(sp)---NC                         |
  1658.        |                                                           |
  1659.        +-----------------------------------------------------------+
  1660.      
  1661.        FIGURE 3-2.  CABLE EXAMPLE: C/30E PSN TO NEARBY EIA-232-D HOST
  1662.  
  1663. DCAC-350-180-( )                                                     4-1
  1664.  
  1665.                       CHAPTER 4.  V.35 HOST INTERFACE
  1666.  
  1667. 1.  Overview.  This chapter describes the electrical and mechanical 
  1668. characteristics of the obsolete DDN V.35 connection at the neighbor or 
  1669. nearby host.  All control signals have electrical characteristics of 
  1670. EIA-232-D, and EIA-232-D signal names are used in the rest of this 
  1671. chapter.  The data and timing signals conform to Recommendation V.35.  
  1672. Like the EIA-232 interface, the V.35 interface is used only where an 
  1673. existing non-DDN-standard PSN provides such an interface, and it is not 
  1674. feasible to install a MIL-STD-188-114 balanced interface prior to 
  1675. upgrading the entire node to DDN-standard (MIL-STD-188-114 balanced serial 
  1676. host interfaces).
  1677.  
  1678. 2.  Electrical Characteristics.
  1679.  
  1680.     a.  Voltage Levels.  The electrical measurements of the C/30E V.35 
  1681. interface circuits are in accordance with CCITT Recommendation V.35.
  1682.     
  1683.     b.  Clocking.  The FD4 fantail contains the connectors that terminate 
  1684. the cables from all I/O interfaces.  The FD4 fantail contains four V.35 
  1685. connectors configured as DTEs.  This interface has clock-sourcing 
  1686. capability allowing either the DCE or C/30E to provide 
  1687. DCAC-350-180-( )                                                     4-2
  1688.  
  1689. the clock.  The hardware can support external clock rates between 300 b/s 
  1690. and 100 kb/s.  Three internal clocks are provided at the following rates:  
  1691. 76.8 kb/s, 57.6 kb/s, 9.6 kb/s.
  1692.  
  1693.         (1)  Signaling Sense.   Signaling sense is in accordance with 
  1694. CCITT Recommendation V.35.  A binary "0"  (space) is transmitted when 
  1695. terminal "A" is positive (+.55v +20%) to terminal "B" (-.55V +20%).  A 
  1696. binary 1 is transmitted when terminal "A" is negative (-.55v +20%) to 
  1697. terminal "B" (+.55v +20%).  The drivers produce a nominal 1.1 volts 
  1698. peak-to-peak signal balanced with respect to ground.
  1699.  
  1700.     c.  Bit Rate/Cable Length.
  1701.  
  1702.         (1)  Maximum Cable Length.  The recommended maximum cable length 
  1703. between a V.35 DCE and DTE is 30 feet when overall shielded, low 
  1704. capacitance, twisted pair cable is used.  Cable lengths of 100 feet are 
  1705. also possible.
  1706.  
  1707.     d.  Interchange  Circuits.
  1708.  
  1709.         (1)  Electrical Use of Interchange Circuits.  The DDN electrical 
  1710. use of interchange circuits is either static or active.  Static circuits 
  1711. are tied by the hardware so that the signal state remains constant on the 
  1712. line, either ON or OFF.  Active circuits change their state under program 
  1713. control.  DDN use of the interchange circuits is shown in table 4-1.
  1714.  
  1715. DCAC-350-180-( )                                                     4-3
  1716.  
  1717.          (2)  Software Use of Interchange Circuits.  Interchange circuit 
  1718. signals are used by the software in different ways.  Active circuits are 
  1719. under program control: either the software reacts to the circuit signal 
  1720. when it changes, or the software can assert a circuit when necessary (such 
  1721. as LL which can be used byoperations personnel for testing connections).  
  1722. Unsupported circuits either are not read by the software or a value is 
  1723. written to the circuit by the software, and that value does not change 
  1724. during operation.  Table 4-1 describes circuit use.
  1725.  
  1726.           (3)  Interchange Circuit Definitions.  EIA-232-D signal names 
  1727. are used throughout this chapter.
  1728.  
  1729.                (a)  Signal Ground.  See EIA-232-D.
  1730.  
  1731.                (b)  DCE Ready.  This circuit must be asserted ON by the 
  1732. DCE, and it is monitored by the PSN software.
  1733.  
  1734.                (c)  Data Set Ready.  This circuit must be asserted on by 
  1735. the DCE, and it is monitored by the PSN.
  1736.  
  1737.                (d)  Transmitted Data.  See EIA-232-D.
  1738.  
  1739.                (e)  Received Data.  See EIA-232-D.
  1740.  
  1741.                (f)  Transmitter Signal Element Timing (DTE Source).  See 
  1742. EIA-232-D.  Also see subsection 2.b of this guide.  This circuit 
  1743. DCAC-350-180-( )                                                     4-4
  1744.  
  1745. provides the clock for Transmitted Data when the PSN sources timing.  The 
  1746. frequency of this circuit should be equal to that of Terminal Receive 
  1747. Timing.
  1748.  
  1749.                (g)  Transmitter Signal Element Timing (DCE Source).  See 
  1750. EIA-232-D.  This circuit provides the clock for Transmitted Data when the 
  1751. DCE sources timing.
  1752.  
  1753.                (h)  Receiver Signal Element Timing (DCE Source).  See 
  1754. EIA-232-D.  This circuit provides clock for Received Data when the DCE 
  1755. sources timing.
  1756.  
  1757.                (i)  Request to Send.  This circuit is asserted ON by PSN 
  1758. software when the link is initialized.
  1759.  
  1760.                (j)  Clear to Send.  This circuit must be asserted ON by 
  1761. the DCE and is monitored by PSN software to determine line status.  If the 
  1762. signal state on this line changes to OFF, the software macrocode will stop 
  1763. data transmission.
  1764.  
  1765.                (k)  Received Line Signal Detector.  This circuit must be 
  1766. asserted ON by the DCE, and is monitored by PSN software to determine line 
  1767. status.  If the signal state on this line changes to OFF, the software 
  1768. macrocode will stop receiving data.
  1769.  
  1770.                (l)  Terminal Receive Timing.  This circuit is received by 
  1771. another DTE via a crossover cable when the C/30E sources 
  1772. DCAC-350-180-( )                                                     4-5
  1773.  
  1774. timing, providing clock for Received Data.  The frequency of this circuit 
  1775. should be equal to that of DTE-Sourced Transmitter Signal Element Timing.  
  1776. This circuit is equivalent to DC in older versions of EIA-232, as 
  1777. referenced in chapter 3.
  1778. DCAC-350-180-( )                                                     4-6
  1779.  
  1780.                    TABLE 4-1. V.35 INTERCHANGE CIRCUIT USE
  1781.  
  1782.                                                                            
  1783.  
  1784.  
  1785. CCITT                                Electrical      Required State of     Comments
  1786. ID    Name                Source       State      Control/Status Signals
  1787.  
  1788. 101   Protective Ground   DTE/DCE    Ground          N/A                   
  1789. 102   Signal Ground       DCE/DTE    Ground          N/A
  1790. 103   Transmitted Data    DTE        Active          N/A                   Data Circuit
  1791. 104   Received Data       DCE        Active          N/A                   Data Circuit
  1792. 105   Request to Send     DTE        Active          ON                    Asserted ON by PSN software.
  1793. 106   Clear to Send       DCE        Active          ON                    Asserted ON by DCE and
  1794.                                                                             monitored by PSN software to
  1795.                                                                             determine line status.
  1796. 107   Data Set Ready      DCE        Active          ON                    Asserted ON by DCE, and
  1797.                                                                             monitored by PSN software.
  1798. 109   Received Line       DCE        Active          ON                    Asserted ON by DCE, and
  1799.       Signal Detector                                                      monitored by PSN software to
  1800.                                                                             determine line status.
  1801. 113   Transmitter Signal  DTE        Active          N/A                   Timing circuit for Transmitted
  1802.       Element Timing                                                       Data when the PSN supplies
  1803.                                                                             timing.
  1804. ---   Terminal Receive    DTE        Active          N/A                   Timing circuit for Received
  1805.       Timing                                                                Data when the PSN supplies
  1806.                                                                             timing.
  1807. 114   Transmitter Signal  DCE        Active          N/A                   Timing circuit for Transmitted
  1808.       Element Timing                                                       Data when the DCE supplies
  1809.                                                                             timing.
  1810. 115   Receiver Signal     DCE        Active          N/A                   Timing circuit for Received
  1811.       Element Timing                                                       Data when the DCE supplies
  1812.                                                                             timing.
  1813.  
  1814.                                                                           
  1815.  
  1816. NOTES:  N/A = Not Applicable
  1817.  
  1818.  
  1819. DCAC-350-180-( )                                                     4-7
  1820.  
  1821. 3.  Mechanical Characteristics.  All V.35 connectors offered for the C/30E 
  1822. meet the specifications provided in this section.  Cables for this 
  1823. interface, supplied by DDN, are equipped with an EIA-449 connector at one 
  1824. end to mate with the EIA-449 connector on the C/30E fantail; the other end 
  1825. provides a MIL-C-28748 34-pin connector to mate with the V.35 DCE.
  1826.  
  1827.     a.  Interface Connectors.  All V.35 connectors on the C/30E fantail 
  1828. are DC-37P type (male) connectors.  They are wired as described in table 
  1829. 4-2.
  1830.  
  1831.         (1)  Intermating dimensions are in accordance with EIA-449-D.
  1832.  
  1833.         (2)  The means for C/30E DTE connectors to latch and unlatch from 
  1834. the latching blocks on the DCE connector are within the dimensions 
  1835. specified in EIA-449, section 3.3.1.  DDN uses the English 4-40 thread 
  1836. latching block.
  1837.  
  1838.     b.  Connector Contact Assignments.  DDN standard node V.35 connector 
  1839. contact assignments are in accordance with CCITT Recommendation V.35 and 
  1840. ISO 2593.  Table 4-2 provides DDN V.35 connector pin assignments.  The 
  1841. signals are used as specified in section 2.d.3.
  1842.  
  1843. DCAC-350-180-( )                                                     4-8
  1844.  
  1845.             TABLE 4-2.  V.35 34-PIN AND 37-PIN CONNECTOR PINOUT
  1846.  
  1847.                                                                           
  1848.  
  1849. 34-pin   37-pin* CCITT      Signal Name                    449
  1850.  #        #      ID                                        Name
  1851.  
  1852. A        1       101        Shield                         FG
  1853. P        4       103        Transmitted Data               SD+
  1854. S        22      103        Transmitted Data               SD- **
  1855. Y        5       114        Transmitter Signal Element     ST+
  1856.                              Timing (DCE Source)
  1857. a/AA     23      114        Transmitter Signal Element     ST-
  1858.                              Timing (DCE Source)
  1859. R        6       104        Received Data                  RD+
  1860. T        24      104        Received Data                  RD-
  1861. C        7       105        Request to Send                RS+
  1862. -        25      102        Signal Ground                  SG
  1863. V        8       115        Receiver Signal Element Timing RT+
  1864.                              (DCE Source)
  1865. X        26      115        Receiver Signal Element Timing RT-
  1866.                              (DCE Source)
  1867. D        9       106        Clear to Send +                CS+
  1868. -        27      102        Signal Ground                  SG
  1869. K        10      141        Local Test Loopback            LL (LT)
  1870. E        11      107        Data Set Ready +               DM+
  1871. -        29      102        Signal Ground                  SG-
  1872. -        31      102        Signal Ground                  SG-
  1873. F        13      109        Received Line Signal Detector  RR
  1874. U        17      ---        Terminal Timing                TT+ ***
  1875. W        35      ---        Terminal Timing                TT- ***
  1876. L        16      ---        Terminal Receive Timing        TRT+ ***
  1877. N        34      ---        Terminal Receive Timing        TRT- ***
  1878. B        19      102        Signal Ground                  SG
  1879. B        37      102        Signal Ground                  SG
  1880.                                                                    
  1881.                                                                           
  1882.  
  1883. * This information represents a straight cable to a V.35 DCE.
  1884. ** The + and - symbols, used in EIA-449, correspond to A and B,
  1885.    respectively, in V.35 terminology.
  1886. *** Internally generated clocks are supplied on pins TT and TRT.
  1887.  
  1888. DCAC-350-180-( )                                                     4-9
  1889.  
  1890. 4.  Interconnecting Cables.
  1891.  
  1892.     a.  For interconnecting cable specifications, see chapter 1, section 
  1893. 4, of this guide.
  1894.  
  1895.     b.  Figure 4-1 is a cabling diagram of a V.35 PSN and nearby V.35 
  1896. host, and figure 4-2 provides an example of an interconnecting cable 
  1897. (BBNCC P/N# 2409320G01).
  1898.  
  1899.  
  1900.  
  1901.    +-------------------------------------------------------------------+
  1902.    |                                                                   |
  1903.    |              V.35S                             DC-37S             |
  1904.    |               /                                  \                |
  1905.    | +--------+  /                                      \  +---------+ |
  1906.    | |  V.35  |--+               2409320G01             +--|  V.35   | |
  1907.    | |  DTE   |P1|======================================|P2|  C/30E  | |
  1908.    | |  Host  |--+                                      +--|  (DTE)  | |
  1909.    | +--------+                                            +---------+ |
  1910.    |                                                                   |
  1911.    |                                                                   |
  1912.    |                                                                   |
  1913.    |                                                                   |
  1914.    +-------------------------------------------------------------------+
  1915.  
  1916.         FIGURE 4-1.  C/30E PSN AND NEARBY V.35 HOST CABLING DIAGRAM
  1917.  
  1918. DCAC-350-180-( )                                                     4-10
  1919.  
  1920.  
  1921.        +-----------------------------------------------------------+
  1922.        |     DTE Host                                    C/30E     |
  1923.        |        P1                                         P2      |
  1924.        |      V.35S                                      DC-37S    |
  1925.        | Pin#     Signal                            Signal    Pin# |
  1926.        |  +/-       +/-   Shield             Shield   +/-      +/- |
  1927.        |  A         FG  >--------+         +-------<  FG       1   |
  1928.        |                                                           |
  1929.        |                 Pair #                                    |
  1930.        |  P/S       SD  >-(1)------\   /-----------<  SD      4/22 |
  1931.        |                             \                             |
  1932.        |  Y/AA      ST  >-(2)---\  /   \ /---------<  TT     17/35 |
  1933.        |                         /     / \                         |
  1934.        |  R/T       RD  >-(3)--/   \ /     \-------<  RD      6/24 |
  1935.        |                           / \                             |
  1936.        |  V/X       RT  >-(4)----/     \-----------<  TRT    16/34 |
  1937.        |                                                           |
  1938.        |  C/NC      RS  >-(5)-----------\   /------<  RS      7/25 |
  1939.        |                                  \                        |
  1940.        |  E/NC      DM  >-(6)--+--------/   \--+---<  DM     11/29 |
  1941.        |                       |               |                   |
  1942.        |  D/NC      CS  >------+               +---<  CS      9/27 |
  1943.        |                       |               |                   |
  1944.        |  F/NC      RR  >------+               +---<  RR     13/31 |
  1945.        |                                                           |
  1946.        |  B/B       SG  >-(7)-+--------------------<  SG/SC  19/37 |
  1947.        |                      |                                    |
  1948.        |                      +--(8)----No Connection (NC)         |
  1949.        |                      |                                    |
  1950.        |                      +--(9)----NC                         |
  1951.        |                      |                                    |
  1952.        |                      +--(10)---NC                         |
  1953.        |                      |                                    |
  1954.        |                      +--(11)---NC                         |
  1955.        |                      |                                    |
  1956.        |                      +--(12)---NC                         |
  1957.        |                      |                                    |
  1958.        |                      +--(sp)---NC                         |
  1959.        |                                                           |
  1960.        +-----------------------------------------------------------+
  1961.     
  1962.          FIGURE 4-2.  CABLE EXAMPLE: C/30E PSN TO NEARBY V.35 HOST
  1963.  
  1964. DCAC-350-180-( )                                                     5-1
  1965.  
  1966.       CHAPTER 5.  MIL-STD-188-114  NEIGHBOR OR NEARBY TRUNK INTERFACE
  1967.  
  1968. 1.  Overview.  This chapter describes the electrical and mechanical 
  1969. characteristics of the MIL-STD-188-114 balanced DTE interface that 
  1970. connects the C/30E PSN with a modem.  DDN supports Extended Modem  Looping 
  1971. (XMOD) through the MIL-STD-188-114 interface. This interface is largely in 
  1972. conformance with the EIA-Standard 449/422, considered the general 
  1973. commercial equivalent to MIL-STD-188-114.  For ease of reference, Table 
  1974. 5-1 equates the EIA-449, EIA-232-D, and CCITT interface signal names.  
  1975. However, in the rest of chapters 5 and 6, only the EIA-449 signal names 
  1976. will be used.
  1977.  
  1978. 2.  Electrical Characteristics.
  1979.  
  1980.     a.  Voltage Levels.  The electrical measurements of the C/30E 188-114 
  1981. interface circuits are in accordance with MIL-STD-188-114, chapter 5, 
  1982. except with regard to subsection 5.1.1.2: Open Circuit Measurement.  The 
  1983. C/30E open circuit driver voltage, measured in accordance with 5.1.1.2, is 
  1984. less than  +9.0V  for balanced drivers and +4.5V for unbalanced drivers.
  1985.  
  1986. DCAC-350-180-( )                                                     5-2
  1987.  
  1988.                  TABLE 5-1.  SIGNAL NAME EQUIVALENCY TABLE
  1989.  
  1990.                                                                           
  1991.  
  1992.  
  1993. EIA-449                             EIA-232-D                                 CCITT
  1994. ID    Name                          ID     Name                               ID      Name
  1995.  
  1996. SG    Signal Ground                 AB     Signal Ground                      102    Signal Ground
  1997. SC    Send Common                   --                                        102a   DTE Common
  1998. RC    Receive Common                --                                        102b   DCE Common
  1999. SD    Send Data                     BA     Transmitted Data                   103    Transmitted Data
  2000. RD    Receive Data                  BB     Received Data                      104    Received Data
  2001. RS    Request To Send               CA     Request To Send                    105    Request To Send
  2002. CS    Clear To Send                 CB     Clear To Send                      106    Ready For Sending
  2003. DM    Data Mode                     CC     Data Set Ready (DCE Ready)         107    Data Set Ready
  2004. TR    Terminal Ready                CD     Data Terminal Ready (DTE Ready)    108/2  Data Terminal Ready
  2005. RR    Receiver Ready                CF     Received Line Signal Detector      109    Data Channel Received Line
  2006.                                                                                       Signal Detector
  2007. IS    Terminal In Service           --                                        ---
  2008. SR    Signaling Rate Selector       CH     Data Signal Rate Selector          111    Data Signaling Rate
  2009.                                             (DTE Source)                              Selector (DTE Source)
  2010. SI    Signaling Rate                CI     Data Signal Rate Selector          112    Data Signaling Rate
  2011.        Indicator                            (DCE Source)                              Selector (DCE Source)
  2012. NS    New Signal                    --                                        ---
  2013. TT    Terminal Timing               DA     Transmitter Signal Element Timing  113    Transmitter Signal Element
  2014.                                             (DTE Source)                              Timing (DTE Source)
  2015. ST    Send Timing                   DB     Transmitter Signal Element Timing  114    Transmitter Signal Element
  2016.                                             (DCE Source)                              Timing (DCE Source)
  2017. RT    Receive Timing                DD     Receiver Signal Element Timing     115    Receiver Signal Element
  2018.                                                                                        Timing (DCE Source)
  2019. SS    Select Standby                --                                        116    Select Standby
  2020. SF    Select Frequency              --                                        126    Select Transmit Frequency
  2021. LL    Local Loopback                LL     Local Loopback                     141    Local Loopback
  2022. RL    Remote Loopback               RL     Remote  Loopback                   140    Remote Loopback
  2023.  
  2024.  
  2025.                                                                           
  2026. DCAC-350-180-( )                                                     5-3
  2027.  
  2028.     b.  Clocking.  Two fantails, MMB and MMBC, provide the EIA-449 
  2029. connectors that terminate cables from all I/O interfaces.  The MMB fantail 
  2030. connector is configured as a DTE.  When the MMB fantail is used, the DCE 
  2031. must provide clock because the MMB fantail does not support clock-sourcing 
  2032. capability.  TheMMBC, a clock-sourcing enhanced fantail, is configured as 
  2033. a DCE and can provide clock.
  2034.  
  2035.         (1)  MMBC Clock Rates.  MMBC and MMB interface hardware support 
  2036. any external clock between 1.2 kb/s and 112 kb/s.  However, DDN policy is 
  2037. that the minimum PSN bit rate be 9.6 kb/s.  When MMBC  clock-sourcing 
  2038. capability is used, the MMBC on-board clock generator provides the 
  2039. frequencies described in Table 5-2.
  2040.  
  2041.  
  2042.            TABLE 5-2.  FREQUENCIES PROVIDED BY THE MMBC FANTAIL
  2043.  
  2044.                                                                           
  2045.  
  2046. Clock Frequency                                Accuracy*
  2047.  
  2048. 112kHz, 64kHz,                                 
  2049. 56kHz, 50kHz                                   +0.005% (50 ppm**) 
  2050.  
  2051.                                                                           
  2052.  
  2053. *  Accuracy over a temperature range of 10 to 30 degrees C.
  2054. ** PPM = Parts Per Million
  2055. DCAC-350-180-( )                                                     5-4
  2056.  
  2057.         (2)  Signaling Sense.  Signaling sense for balanced and unbalanced 
  2058. circuits is in accordance with EIA-422-A with the exception that the 
  2059. differential voltage applied to the interconnecting cable is in the range 
  2060. of 2 volts to 9 volts for the C/30E.  As defined in EIA-422-A, ON (0, 
  2061. Space, or +) is generated when A terminal is positive with respect to the 
  2062. B terminal,  and OFF (1,  MARK, or -) is generated when A terminal is 
  2063. negative with respect to the B terminal.
  2064.  
  2065.         (3)  On-Board Jumpers.  There are three jumper option pairs on the 
  2066. MMB:
  2067.  
  2068.     --1  Used for RS-422 mode (balanced Category I cirduits)
  2069.     --2  Used for RS-423 mode (unbalanced Category I circuits)
  2070.     --3  Used for normal (univerted) data operation
  2071.     --4  Used to invert transmit and receive data
  2072.     --5  Used for invert data in RS-423 mode
  2073.     --6  Used for RS-422 mode or normal data in RS-423 mode
  2074.  
  2075. Boards are shipped from the factory with steps 1, 3, 6 selected.
  2076.  
  2077.     c.  Bit Rate and Cable Length.  Interconnecting cable length and its 
  2078. relation to data signaling rates are in accordance with EIA Standard 449, 
  2079. section 6.10, and EIA Standard 422-A, section 4.3 and the appendix.
  2080.  
  2081. DCAC-350-180-( )                                                     5-5
  2082.  
  2083.         (1)  Maximum Cable Length.  The maximum length of the cable is 
  2084. 1000 feet.
  2085.  
  2086.         (2)  Slew Rate Limiting.  Signal rise time is set to 1 microsecond 
  2087. (100 kb/s value).
  2088.  
  2089.     d.  Interchange Circuits.  There are two EIA-449 trunk interfaces: a 
  2090. non-clock-sourcing interface provided by the MMB daughterboard, and a 
  2091. clock-sourcing interface provided by the MMBC daughterboard.  The 
  2092. difference in the implementation of these two interfaces is described in 
  2093. this section, as well as in tables 5-3 and 5-4.
  2094.  
  2095.         (1)  Electrical Use of Interchange Circuits.  The DDN electrical 
  2096. use of interchange circuits is either static or active.  Static circuits 
  2097. are tied by the hardware so that the signal state remains constant on the 
  2098. line, either ON or OFF.  Active circuits change their state under program 
  2099. control.  DDN use of the interchange circuits is shown in Tables 5-3 and 
  2100. 5-4.
  2101.  
  2102.         (2)  Software Use of Interchange Circuits.  Interchange circuit 
  2103. signals are used by the software in different ways.  Active circuits are 
  2104. under program control:  the software canreact to a received signal when it 
  2105. changes, and the software can assert a transmitted signal when necessary 
  2106. (such as RS, TR, and LL which can be used by operations personnel for 
  2107. testing connections).  Unsupported circuits are either not read by the 
  2108. software or a value is written to the circuit by the software and that 
  2109. DCAC-350-180-( )                                                     5-6
  2110.  
  2111. value does not change during operation.  Tables 5-3 and 5-4 provides a 
  2112. list of circuits and their use.
  2113.  
  2114.         (3)  Interchange Circuit Definitions.  For additional information 
  2115. about these interchange circuits, see EIA Standard 449.  The following 
  2116. descriptions assume use of full period/full duplex circuits, with flow 
  2117. control handled at higher levels.
  2118.  
  2119.              (a)  Signal Ground.  See EIA Standard EIA-449.
  2120.  
  2121.              (b)  Send Common.  See EIA Standard EIA-449.
  2122.  
  2123.              (c)  Receive Common.  See EIA Standard EIA-449.
  2124.  
  2125.              (d)  Terminal in Service.  For the non-clock-sourcing 
  2126. interface, IS is tied ON by the hardware.  For the clock-sourcing 
  2127. interface, this circuit is not connected.
  2128.  
  2129.              (e)  Incoming Call.  IC is not connected. 
  2130.              
  2131.              (f)  Terminal Ready.  For the non-clock-sourcing interface, 
  2132. TR is asserted OFF by PSN software when the link is initialized and allows 
  2133. Monitoring Center control.  For the clock-sourcing interface, TR is not 
  2134. connected.
  2135.  
  2136.              (g)  Data Mode.  For the non-clock-sourcing interface, 
  2137. DCAC-350-180-( )                                                     5-7
  2138.  
  2139. DM is not monitored by the PSN software.  For the clock-sourcing 
  2140. interface, DM is asserted ON by hardware.
  2141.  
  2142.              (h)  Send Data.  See EIA Standard EIA-449.
  2143.  
  2144.              (i)  Receive Data.  See EIA Standard EIA-449.
  2145.  
  2146.              (j)  Terminal Timing.   See EIA Standard EIA-449. TT is 
  2147. supported as a "reflected clock" in phase with ST.
  2148.  
  2149.              (k)  Send Timing.  See EIA Standard EIA-449.
  2150.  
  2151.              (l)  Receive Timing.  See EIA Standard EIA-449.
  2152.  
  2153.              (m)  Request to Send.  For the non-clock-sourcing interface, 
  2154. RS is asserted OFF by the PSN software when the link is initialized. RS 
  2155. allows Monitoring Center control.  For the clock-sourcing interface, RS is 
  2156. not connected.
  2157.  
  2158.              (n)  Clear to Send. For the non-clock-sourcing interface, CS 
  2159. is not monitored by the PSN software.  For the clock-sourcing interface, 
  2160. CS is asserted ON by hardware.
  2161.  
  2162.              (o)  Receiver Ready.  For the non-clock-sourcing interface, 
  2163. RR is not monitored by PSN software.  For the clock-sourcing interface, RR 
  2164. is asserted ON by hardware.
  2165. DCAC-350-180-( )                                                     5-8
  2166.  
  2167.              (p)  New Signal.  For the non-clock-sourcing interface, NS is 
  2168. tied OFF by the hardware.  For the clock-sourcing interface, NS is not 
  2169. connected.
  2170.  
  2171.              (q)  Select Frequency.  For the non-clock-sourcing interface, 
  2172. SF/SR is electrically active and asserted OFF by the hardware when the 
  2173. link is initialized.  For the clock-sourcing interface, SF/SR is not 
  2174. connected.
  2175.  
  2176.              (r)  Signaling Rate Selector.  See Select Frequency, 2.d.3.q 
  2177. above for a description.
  2178.  
  2179.              (s)  Signaling Rate Indicator.  SI is not connected.
  2180.  
  2181.              (t)  Local Loopback.  For the non-clock-sourcing interfaces, 
  2182. LL is electrically active, but asserted OFF by PSN software when the link 
  2183. is initialized.  LL can be controlled by the Monitoring Center.  For the 
  2184. clock-sourcing interface, LL is not connected.
  2185.  
  2186.              (u)  Remote Loopback.  RL is electrically active, but 
  2187. asserted OFF by PSN software when the link is initialized.  For the 
  2188. non-clock-sourcing interface, RL is not available for Monitoring Center 
  2189. control.  For the clock-sourcing interface, RL is asserted when another 
  2190. DCE requests the PSN to enter remote loopback.
  2191.  
  2192.              (v)  Test Mode. For the non-clock-sourcing interface, TM 
  2193. DCAC-350-180-( )                                                     5-9
  2194.  
  2195. is not connected.  For the clock-sourcing interface, TM is OFF during 
  2196. normal operations but ON during loopback operations to acknowledge the 
  2197. loopback request from another DCE.
  2198.  
  2199.              (w)  Select Standby.  For the non-clock-sourcing interface, 
  2200. SS is tied OFF by hardware.  For the clock-sourcing interface, SS is not 
  2201. monitored by PSN software but it is used as the remote loop indicator when 
  2202. the PSN requests another DCE to enter remote loopback.
  2203.         
  2204.              (x)  Standby Indicator.  For the non-clock-sourcing 
  2205. interface, SB is not connected.  For the clock-sourcing interface, SB is 
  2206. OFF during normal operations, and it is used as the remote loop request 
  2207. signal for loopback operations when the PSN requests another DCE to enter 
  2208. remote loopback.
  2209. DCAC-350-180-( )                                                     5-10
  2210.  
  2211.       TABLE 5-3. DDN STANDARD NODE MMB*/MMBC INTERCHANGE CIRCUIT USE
  2212.  
  2213.                                                                           
  2214.  
  2215.  
  2216. 449                                            Electrical       Required State of   Comments
  2217. ID     EIA-449 Name            Source          Circuit       Control/Status Signals
  2218.  
  2219. SG     Signal Ground           DTE/DCE         Ground                 N/A           Ground
  2220. SC     Send Common             DTE             Ground                 N/A           Common
  2221. RC     Receive Common          DCE             Ground                 N/A           Common
  2222. SD     Send Data               DTE             Active                 N/A           Data Circuit
  2223. RD     Receive Data            DCE             Active                 N/A           Data Circuit
  2224. RS     Request to Send         DTE             Active                 OFF           Asserted OFF by PSN software.
  2225.                                                                                      Treated as LL for XMOD.
  2226. CS     Clear to Send           DCE             Active                 Don't Care    Not monitored by PSN software. 
  2227. DM     Data Mode               DCE             Active                 Don't Care    Not monitored by PSN software.
  2228. TR     Terminal Ready          DTE             Active                 OFF           Asserted OFF by PSN software.
  2229.                                                                                      Treated as RL for XMOD.
  2230. RR     Receiver Ready          DCE             Active                 Don't Care    Not monitored by PSN software. 
  2231. SQ     Signal Quality          DCE             Not Connected          Don't Care    Not connected in PSN. 
  2232. SF/SR  Select Frequency/       DTE             Static                 OFF           Tied OFF by hardware.
  2233.         Signaling Rate Sel.
  2234. SI     Signaling Rate          DCE             Not Connected          Don't Care    Not connected in PSN.
  2235. TT     Terminal Timing         DTE             Active                 N/A           Timing circuit for Transmitted
  2236.                                                                                     Data when PSN supplies timing.
  2237. ST     Send Timing             DCE             Active                 N/A           Timing circuit for Transmitted
  2238.                                                                                     Data when DCE provides timing.
  2239. RT     Receive Timing          DCE             Active                 N/A           Timing circuit for Received
  2240.                                                                                     Data when DCE provides timing.
  2241. SS     Select Standby          DTE             Static                 OFF           Tied OFF by hardware.
  2242. SB     Standby Indicator       DCE             Not Connected          Don't Care    Not connected in PSN.
  2243. IC     Incoming Call           DCE             Not Connected          Don't Care    Not connected in PSN. 
  2244. LL     Local Loopback          DTE             Active                 OFF           Tied to OFF by PSN software.
  2245.                                                                                      Treated as CL for XMOD.
  2246. RL     Remote Loopback         DTE             Static                 OFF           Tied OFF by hardware. 
  2247. TM     Test Mode               DCE             Not Connected          Don't Care    Not connected in PSN.
  2248. NS     New Signal              DTE             Static                 OFF           Tied OFF by hardware.
  2249. IS     Terminal in Service     DTE             Static                 ON            Tied ON by hardware.
  2250. AT     Alternate Timing        DTE             Not Connected          N/A           Not monitored by PSN software.
  2251.  
  2252.  
  2253.                                                                           
  2254.  
  2255. NOTE:  N/A = Not Applicalbe 
  2256. * MMB provides a non-clock-sourcing (DTE) interface.
  2257.     
  2258. DCAC-350-180-( )                                                     5-11
  2259.  
  2260. 3.  Mechanical Characteristics.  All EIA-449/422 connectors offered for 
  2261. the C/30E meet the following specifications.
  2262.  
  2263.     a.  Interface Connectors.  All C/30E EIA-449 connectors interfacing an 
  2264. MMB with an MMBC have DC-37P type (male) connectors for  the  MMB side and 
  2265. a DC-37S type (female) connectors for the MMBC side.  Two interfacing 
  2266. MMBC-configured PSNs use two DC-37P connectors.
  2267.  
  2268.         (1)  Intermating dimensions are in accordance with EIA-449, 
  2269. section 3.3.1.
  2270.  
  2271.         (2)  The means for C/30E DTE connectors to latch and unlatch from 
  2272. the latching blocks on the DCE connector are within the dimensions 
  2273. specified in EIA-449, section 3.3.2.  DDN uses the English 4-40 thread 
  2274. latching block.
  2275.  
  2276.     b.  Connector Contact Assignments.  All C/30E EIA-449/422 contact 
  2277. assignments are in accordance with EIA-449, section 3.4.  Table 5-4 
  2278. provides the DDN standard node connector pinout.  The signals are used as 
  2279. specified in section 2.d.3 of the Standard.
  2280. DCAC-350-180-( )                                                     5-12
  2281.  
  2282.        TABLE 5-4.   DDN STANDARD NODE EIA-449 (DTE) CONNECTOR PINOUT
  2283.  
  2284.                                                                           
  2285.  
  2286. Pin     EIA     CCITT   Name
  2287.         ID      ID
  2288.  
  2289. 1       FG              Frame Ground
  2290. 2       SI      111     Not Connected
  2291. 20      RC      102b    Receive Common
  2292. 3       AT      ---     Not Connected
  2293. 21      AT      ---     Not Connected
  2294. 4       SD      103     Send Data +
  2295. 22      SD      103     Send Data -
  2296. 5       ST      114     Send Timing +
  2297. 23      ST      114     Send Timing -
  2298. 6       RD      104     Receive Data +
  2299. 24      RD      104     Receive Data -
  2300. 7       RS      105     Request to Send +
  2301. 25      RS      105     Request to Send -
  2302. 8       RT      115     Receive Timing +
  2303. 26      RT      115     Receive Timing -
  2304. 9       CS      106     Clear to Send +
  2305. 27      CS      106     Clear to Send -
  2306. 10      LL      141     Local Loopback
  2307. 28      IS      ---     Tied to "1" on MMB, Not Connected on MMBC
  2308. 11      DM      107     Data Mode +
  2309. 29      DM      107     Data Mode -
  2310. 12      TR      108.2   Terminal Ready +
  2311. 30      TR      108.2   Terminal Ready -
  2312. 13      RR      109     Receiver Ready +
  2313. 31      RR      109     Receiver Ready 
  2314. 14      RL      140     Remote Loopback - Tied to "0" on MMB,
  2315.                           Active on MMBC
  2316. 32      SS      116     Select Standby - Tied to "0"
  2317. 15      IC      125     Incoming Call
  2318. 33      SQ      110     Signal Quality
  2319. 16      SF/SR   126     Select Frequency/Signaling Rate
  2320.                          Tied to "1"
  2321. 34      NS      ---     New Signal - Tied to "0"
  2322. 17      TT      113     Terminal Timing +
  2323. 35      TT      113     Terminal Timing -
  2324. 18      TM      142     Not Connected - MMBC Has This
  2325. 36      SB      117     Not Connected - MMBC Has This
  2326. 19      SG      102     Signal Ground
  2327. 37      SC      102a    Send Common
  2328.  
  2329.                                                                           
  2330. DCAC-350-180-( )                                                     5-13
  2331.  
  2332. 4.  Interconnecting Cables.
  2333.  
  2334.     a.  For interconnecting cable specifications, see chapter 1, section 
  2335. 4, of this guide.
  2336.  
  2337.     b.  Figure 5-1 is a cabling diagram of a C/30E PSN connected to a 
  2338. nearby EIA-449 PSN via an MMB-MMBC configuration.  Figure  5-2  is a 
  2339. cabling diagram of a C/30E PSN connected to a nearby EIA-449 PSN via an 
  2340. MMBC-MMBC configuration, the preferred configuration for the DDN. Figure 
  2341. 5-3 is an example of a cable used to interconnect the MMB-MMBC 
  2342. configuration, whereas  figure  5-4 illustrates the MMBC-MMBC nearby 
  2343. EIA-449 PSN connection.
  2344.  
  2345.         (1)  Conductor Size.  Interconnecting cables should be in 
  2346. accordance with MIL-STD-188-114, Appendix 10, with regard to conductor 
  2347. size 
  2348. (subsection 10.1.1).  Interconnecting cables or wires should be composed 
  2349. of wires of a 24 AWG or larger conductor for solid or stranded copper 
  2350. wires, or for non-copper conductors a sufficient size to yield a dc wire 
  2351. resistance not to exceed 30 ohms/1000 feet per conductor.
  2352.  
  2353.         (2)  Mutual Pair Capacitance.  In accordance with MIL-STD-188-114, 
  2354. the capacitance between one wire in the pair to the other wire in the pair 
  2355. should not exceed 20 picofarads/foot, and the value should be reasonably 
  2356. uniform over the length of the wire or cable.
  2357. DCAC-350-180-( )                                                     5-14
  2358.  
  2359.         (3)  Stray Capacitance.  In accordance with MIL-STD-188-144, the 
  2360. capacitance between ome wire in the cable to all others in the cable 
  2361. sheath, with all others connected to ground, should not exceed 40 
  2362. picofarads/foot, and should be reasonably uniform for a given conductor 
  2363. over the lenght of the wire or cable.
  2364.  
  2365.         (4)  Pair-to-Pair Balanced Crosstalk.  In accordance with 
  2366. MIL-STD-188-144, Appendix 10, with regard to pair-to-pair balanced 
  2367. crosstalk (subsection 10.1.4), the crosstalk from one pair of wires to any 
  2368. other pair in the same cable sheath should have a minimun value of 40 dB 
  2369. attenuation measured at 150 kHz.
  2370.  
  2371. DCAC-350-180-( )                                                     5-15
  2372.  
  2373.  
  2374.       +-------------------------------------------------------------+
  2375.       |                                                             |
  2376.       |                DC-37PS                  DC-37P              |
  2377.       | +----------+    /                         \    +----------+ |
  2378.       | | EIA-499  |  /                             \  |  C/30E   | |
  2379.       | |  C/30E   |--+        2409327G01           +--| EIA-449  | |
  2380.       | |   DTE    |P1|=============================|P2|   DCE    | |
  2381.       | |  (MMB)   |--+                             +--|  (MMBC)  | |
  2382.       | |          |                                   |          | |
  2383.       | +----------+                                   +----------+ |
  2384.       |                                                             |
  2385.       +-------------------------------------------------------------+
  2386.  
  2387.       FIGURE 5-1.  C/30E EIA-449 PSN AND NEARBY EIA-449 PSN CABLING 
  2388.                    DIAGRAM (C/30E SOURCES CLOCK)
  2389.  
  2390.  
  2391.  
  2392.  
  2393.       +-------------------------------------------------------------+
  2394.       |                                                             |
  2395.       |                DC-37P                   DC-37P              |
  2396.       | +----------+    /                         \    +----------+ |
  2397.       | |          |  /                             \  |          | |
  2398.       | |  C/30E   |--+        2409328G01           +--|  C/30E   | |
  2399.       | |  MMBC    |P1|=============================|P2|  MMBC    | |
  2400.       | |   DCE    |--+                             +--|   DCE    | |
  2401.       | |          |                                   |          | |
  2402.       | +----------+                                   +----------+ |
  2403.       |                                                             |
  2404.       +-------------------------------------------------------------+
  2405.  
  2406.       FIGURE 5-2.  C/30E PSN WITH MMBC TO EIA-449 NEARBY PSN CABLING
  2407.                    DIAGRAM WITH MMBC (C/30E SOURCES CLOCK)
  2408.  
  2409. DCAC-350-180-( )                                                     5-16
  2410.  
  2411.  
  2412.       +-----------------------------------------------------------+
  2413.       |       MMB                                        MMBC     |
  2414.       |      C/30E                                       C/30E    |
  2415.       |        P1                                         P2      |
  2416.       |      DC-37S                                      DC-37S   |
  2417.       | Pin#     Signal                            Signal    Pin# |
  2418.       |  +/-       +/-   Shield             Shield   +/-      +/- |
  2419.       |  1         FG  >--------+         +-------<  FG       1   |
  2420.       |                                                           |
  2421.       |                                                           |
  2422.       |                 Pair #                                    |
  2423.       |  4/22      SD  >-(1)----------------------<  SD      4/22 |
  2424.       |                                                           |
  2425.       |  5/23      ST  >-(2)----------------------<  ST      5/23 |
  2426.       |                                                           |
  2427.       |  6/24      RD  >-(3)----------------------<  RD      6/24 |
  2428.       |                                                           |
  2429.       |  8/26      RT  >-(4)----------------------<  RT      8/26 |
  2430.       |                                                           |
  2431.       |  12/30     TR  >-(5)----------------------<  TR     12/30 |
  2432.       |                                                           |
  2433.       |  9/27      CS  >-(6)----------------------<  CS      9/27 |
  2434.       |                                                           |
  2435.       |  19/37   SG\SC >-(7)----------------------<  SG/SC  19/37 |
  2436.       |                                                           |
  2437.       |  11/29     DM  >-(8)----------------------<  TM     20/18 |
  2438.       |                                                           |
  2439.       |  13/31     RR  >-(10)-+-------------------<  RR     13/31 |
  2440.       |                       |                                   |
  2441.       |  7/SC      RS  >-(11)-|-------------------<  RL     14/NC |
  2442.       |                       |                                   |
  2443.       |  17/35     TT  >-(12)-|-------------------<  TT     17/35 |
  2444.       |                       |                                   |
  2445.       |                       +-(9)--- NO CONNECTION              |
  2446.       |                                     (NC)                  |
  2447.       |                                                           |
  2448.       |                                                           |
  2449.       +-----------------------------------------------------------+
  2450.  
  2451.       FIGURE 5-3.  CABLING EXAMPLE: C/30E WITH MMB TO EIA-449 NEARBY
  2452.                    PSN WITH MMBC (C/30E SOURCES CLOCK)
  2453. DCAC-350-180-( )                                                     5-17
  2454.  
  2455.  
  2456.        +-----------------------------------------------------------+
  2457.        |      MMBC                                        MMBC     |
  2458.        |      C/30E                                       C/30E    |
  2459.        |       P1                                          P2      |
  2460.        |      DC-37P                                      DC-37P   |
  2461.        | Pin#     Signal                            Signal    Pin# |
  2462.        |  +/-       +/-   Shield             Shield   +/-      +/- |
  2463.        |  1         FG  >--------+         +-------<  FG       1   |
  2464.        |                                                           |
  2465.        |                                                           |
  2466.        |                 Pair #                                    |
  2467.        |  4/22      SD  >-(1)-------\  /----------->  SD      4/22 |
  2468.        |                              \                            |
  2469.        |  6/24      RD  >-(3)-------/   \---------->  RD      6/24 |
  2470.        |                                                           |
  2471.        |  8/26      RT  >-(4)----\              /--<  RT      8/26 |
  2472.        |                          \            /                   |
  2473.        |  12/30     TR  >-(5)------\----------/----<  TR     12/30 |
  2474.        |                            \        /                     |
  2475.        |  9/27      CS  >-(6)--------\------/------<  CS      9/27 |
  2476.        |                              \    /                       |
  2477.        |  19/37   SG\SC >-(7)----------\--/--------<  SG/SC  19/37 |
  2478.        |                                \/                         |
  2479.        |  32/NC     DM  >-(8)-----------/\---------<  TM     18/SG |
  2480.        |                               /  \                        |
  2481.        |  18/SG     TM  >-(10)--------/----\-------<  SS     32/NC |
  2482.        |                             /      \                      |
  2483.        |  14/NC     RL  >-(11)------/--------\-----<  SB     36/SG |
  2484.        |                           /          \                    |
  2485.        |  17/35     TT  >-(12)-+--/            \---<  TT     17/35 |
  2486.        |                       |                                   |
  2487.        |                >------|-(2)--- NO CONNECTION              |
  2488.        |                       |             (NC)                  |
  2489.        |                       +-(5)--- NC                         |
  2490.        |                       |                                   |
  2491.        |                       +-(9)--- NC                         |
  2492.        |                                                           |
  2493.        +-----------------------------------------------------------+
  2494.  
  2495.       FIGURE 5-4.  CABLING EXAMPLE: C/30E WITH MMBC TO EIA-449 NEARBY
  2496.                    PSN WITH MMBC (C/30E SOURCES CLOCK)
  2497.  
  2498. DCAC-350-180-( )                                                     6-1
  2499.  
  2500.             CHAPTER 6.  MIL-STD-188-114  REMOTE TRUNK INTERFACE
  2501.  
  2502. 1.  Overview.  This chapter describes the electrical and mechanical 
  2503. characteristics of the MIL-STD-188-114 balanced remote trunk interface.  
  2504. DDN supports Extended Modem Looping (XMOD) through the MIL-STD-188-114 
  2505. interface. This chapter also documents the interface between the remote 
  2506. modem and the PSN (demarcation point A in figure 6-1) with no intervening 
  2507. cryptographic devices (KG-84As).  Eventually KG-84As will be required for 
  2508. all trunk circuits; therefore, chapter 6 also provides an example of the 
  2509. cabling that connects from the remote modem to the remote Fixed Plant 
  2510. Adapter (FPA) and then to the PSN (demarcation point B in figure 6-2).
  2511.  
  2512. 2.  Electrical Characteristics.
  2513.  
  2514.     a.  Voltage  Levels.   The  modems used will conform  to  EIA Standard 
  2515. 449.  The electrical interface of the KG-84A is in accordance with 
  2516. MIL-STD-188-114, chapter 5, except with regard to subsection 5.1.1.2: Open 
  2517. Circuit Measurement.  The open circuit driver voltage, measured in 
  2518. accordance with section 5.1.1.2 of this 
  2519.  
  2520. DCAC-350-180-( )                                                     6-2
  2521.  
  2522. statement, is less than +9.0V for balanced drivers and +4.50V for 
  2523. unbalanced drivers.
  2524.  
  2525.     b.  Clocking.
  2526.  
  2527.         (1)  Modem Clocking.  The modem supplies timing on the Send Timing 
  2528. and Receive Timing circuits.  Terminal Timing isnot supported for remote 
  2529. PSN interfaces.  While the DDN hardware will support between 1.2 kb/s and 
  2530. 64 kb/s, DDN policy states that the minimum PSN access rate be 9.6 kb/s.
  2531. DCAC-350-180-( )                                                     6-3
  2532.  
  2533.  
  2534.      +--------------------------------------------------------------+
  2535.      |                                                              |
  2536.      |                                                              |
  2537.      | C/30E PSN                                      C/30E PSN     |
  2538.      | +-----------+   +-----------+ +-----------+    +-----------+ |
  2539.      | |           |   |           | |           |A   |           | |
  2540.      | |118-114 Bal|---|188-114 Bal|-|188-114 Bal|----|118-114 Bal| |
  2541.      | |   DTE     |   |   DCE     | |   DCE     |    |   DTE     | |
  2542.      | |           |   |           | +           |    |           | |
  2543.      | +-----------+   +-----------+ +-----------+    +-----------+ |
  2544.      |                                                              |
  2545.      |                                                              |
  2546.      |                                                              |
  2547.      +--------------------------------------------------------------+
  2548.  
  2549.       FIGURE 6-1.  DEMERCATION POINT "A" BETWEEN THE C/30 AND REMOTE 
  2550.                    C/30E
  2551.  
  2552.  
  2553.  
  2554.    +-------------------------------------------------------------------+
  2555.    |   C/30E PSN                                           C/30E PSN   |
  2556.    | +-----------+                                       +-----------+ |
  2557.    | |118-114 Bal|                                       |           | |
  2558.    | |   DTE     |                                       |118-114 Bal| |
  2559.    | |           |                                       |   DTE     | |
  2560.    | |           |                                       |           | |
  2561.    | +-----+-----+                                       +-----+-----+ |
  2562.    |       |                                                   |       |
  2563.    |       |                                                   |       |
  2564.    |   +---+---+                                           +---+---+   |
  2565.    |   | DPPE  |                                           | DPPE  |   |
  2566.    |   +---+---+                                           +---+---+   |
  2567.    |       |                                                   |       |
  2568.    |       |                                                   |       |
  2569.    |       |      +--+ +-----------+ +-----------+  +---+      |B      |
  2570.    |   +---+---+  |D | |           | |           |  |D  |  +---+---+   |
  2571.    |   | KGAB  |--|P |-|188-114 Bal|-|188-114 Bal|--|P  |--| KGAB  |   |
  2572.    |   |       |  |P | |           | |   DCE     |  |P  |  |       |   |
  2573.    |   +-------+  |C | |           | |           |  |C  |  +-------+   |
  2574.    |              +--+ +-----------+ +-----------+  +---+              |
  2575.    |                                                                   |
  2576.    |                                                                   |
  2577.    +-------------------------------------------------------------------+
  2578.  
  2579.      FIGURE 6-2.  DEMERCATION POINT "B" BETWEEN THE KGAB AND C/30E PSN
  2580. DCAC-350-180-( )                                                     6-4
  2581.  
  2582.         (2)  Signaling Sense.  Signaling sense for balanced and unbalanced 
  2583. circuits is in accordance with EIA Standard 422-A with  the exception of 
  2584. the differential voltage, which applied to the interconnecting cable, is 
  2585. in the C/30E range of 2 volts to 9 volts.  As defined in EIA Standard 
  2586. 422-A, ON (0, Space, or +) is generated when the A terminal is positive 
  2587. with respect to the B terminal, and OFF (1, MARK, or -) is generated when 
  2588. the A terminal is negative with respect to the B terminal.
  2589.  
  2590.     c.  Bit Rate and Cable Length.
  2591.  
  2592.         (1)  EIA-449 Compliance.  Interconnecting cable length and its 
  2593. relation to data signaling rates are in accordance with EIA Standard 449, 
  2594. section 6.10, and EIA Standard 422-A, section 4.3 and the Appendix.
  2595.  
  2596.         (2)  Maximum Cable Length.  The maximum cable length between the 
  2597. remote modem and the PSN, including the intervening FPA is 1000 feet; 
  2598. however, cable lengths less than 200 feet are preferred.
  2599.  
  2600.     d.  Interchange Circuits.
  2601.  
  2602.         (1)  C/30E Local Modem Interface.
  2603.  
  2604.              (a)  Signal flow between the C/30E and the local modem is 
  2605. shown in figure 6-3.  This interface and associated hardware are provided 
  2606. by DDN.  The signal flow is the same when a KG-84A is used.  This 
  2607. interface uses EIA-449 pin assignments.
  2608.              
  2609. DCAC-350-180-( )                                                     6-5
  2610.  
  2611.              (b)  As shown in figure 6-3, the supported signals are Send 
  2612. Data (SD), Send Timing (ST), Receive Data (RD), and Receive Timing (RT).  
  2613. Clear to Send (CS), Data Mode (DM), and ReceiverReady (RR) are tied ON by 
  2614. the cable connected to the fantail.Terminal Ready (TR) is being used for 
  2615. the Remote Loopback (RL) function.  Request to Send (RS) is being used for 
  2616. the Local Loopback (LL) function.  The signal LL is being used for the 
  2617. COMSEC Loopback (CL) described below.
  2618.  
  2619.              (c)  A special DDN-specific loopback signal, CL, is provided 
  2620. as shown in figure 6-3.  The Local Loopback (LL) signal is used by the PSN 
  2621. to loop the local KG-84A and is designated as  "C" loop or CL (standing 
  2622. for COMSEC Loopback) in figure 6-3 after it leaves the C/30E fantail.  
  2623.  
  2624. 3.  Mechanical Characteristics.  All EIA-449/422 connectors offered for 
  2625. the C/30E meet the specifications of this section.
  2626.  
  2627.     a.  Interface Connectors.  DDN MIL-STD-188-114 DCE connectors are 
  2628. DC-37S type (female) and DC-37P type (male) connectors.  The DDN FPA uses 
  2629. an MS connector on the KGAB counter assemblies.
  2630.  
  2631.     b.  Connector Contact Assignments.
  2632.  
  2633.         (1)  C/30E Connectors.  All DDN EIA-449/422 contact assignments 
  2634. are in accordance with EIA Standard 449, section 3.4.  In chapter 1, Table 
  2635. DCAC-350-180-( )                                                     6-6
  2636.  
  2637. 5-4 provides the standard DTE pinouts and section 2.d.3 of the Standard 
  2638. provides circuit descriptions.
  2639.  
  2640.         (2)  KGAB Connectors.  KGAB connectors to the remote C/30E and the 
  2641. remote modem are shown in Tables 6-2 and 6-3, respectively.
  2642. DCAC-350-180-( )                                                     6-7
  2643.  
  2644.  
  2645.  
  2646. PSN/                  Patch                                        Patch                DCE
  2647. MII         Cable #   Panel   Cable #         KGAB       Cable #   Panel   Cable #       
  2648.              6833              6817                       6812              7835         
  2649.                       Pin #                                        Pin #                 
  2650. +--+ Pin #  +-----+  +-----+ +-----+   Pin #  +--+  Pin #  +----+ +-----+ +----+  Pin # +--+
  2651. |  |  +/-   |     |  | +/- | |     |    +/-   |  |   +/-   |    | | +/- | |    |   +/-  |  |
  2652. |SD|  4/22 --------->| 2/14|---(1)---> 24/25  |SD|  2/3  -------->| 2/14|--------> 4/22 |SD|
  2653. |  |                 |     |                  |  |                |     |               |  |
  2654. |ST|  5/23 --------->|15/16|<--(2)----  4/5   |ST|  4/5  <--------|15/16|<-------- 5/23 |ST|
  2655. |  |                 |     |                  |  |                |     |               |  |
  2656. |RD|  6/24 --------->| 3/19|<--(3)----  6/7   |RD|  6/7  <--------| 3/19|<-------- 6/24 |RD|
  2657. |  |                 |     |                  |  |                |     |               |  |
  2658. |RT|  8/26 --------->|17/18|<--(4)----  8/9   |RT|  8/9  <--------|17/18|<-------- 8/26 |RT|
  2659. |  |                 |     |                  |  |                |     |               |  |
  2660. |SR/ 12/30 --------->|20/10|---(5)---> 10/11  |TR| 10/11  ------->|20/10|----+--->12/30 |TR|
  2661. |NS|                 |     |                  |  |                |     |    |          |  |
  2662. |  |                 |     |                  |  |                |     |    +---> 7/25 |RS|
  2663. |  |                 |     |                  |  |                |     |               |  |
  2664. |  |       NC<-------| 5/6 |<--(6)---- 14/15  |CS| 12/13  <-------| 5/6 |<-------- 9/27 |CS|
  2665. |  |                 |     |                  |  |                |     |               |  |
  2666. |SG| 19/37 ------+---| 7/8 |---(7)---> 12/13  |SG| 14/15  --------| 7/8 |--------- 19/37|SG|
  2667. |  |             |   |     |                  |  |                |     |               |  |
  2668. |SR| 16/37 ------|-->|12/13|---(8)---> 16/17  |CL| 16/17  ------->|12/13|------> NC     |  |
  2669. |  |             |   |     |                  |  |                |     |               |  |
  2670. |RL| 14/37 ------|-->|11/21|---(9)---> 18/19  |RL| 18/19  ------->|11/21|-------->14/37 |RL|
  2671. |  |             |   |     |                  |  |                |     |               |  |
  2672. |RS|  7/37 ------|-->| 4/9 |---(10)--> 20/21  |DL| 20/21  ------->| 4/9 |------> NC     |  |
  2673. |  |             |   |     |                  |  |                |     |               |  |
  2674. |LL| 10/37 ------|-->|22/25|---(11)--> 22/23  |LL| 22/23  ------->|22/25|-------->10/37 |LL|
  2675. |  |             |   |     |                  |  |                |     |               |  |
  2676. |ON| 28/32 --->+ +-->|24/23|---(12)-->  2/3   |TT| 24/25  ------->|24/23|-------->17/35 |TT|
  2677. |CS|  9/27 <---|     +-----+                  +--+                +-----+               |  |
  2678. |DM| 11/29 <---|                                                                        |  |
  2679. |RR| 13/31 <---|                                                                        |  |
  2680. +--+                                                                                    +--+
  2681.    Notes:  1.  Pin numbers are the same on both sides of Patch Panel.
  2682.            2.  Encircled numbers are the cable pair numbers.
  2683.  
  2684.  
  2685.     FIGURE 6-3.  FUNCTIONAL SIGNAL FLOW BETWEEN A NEARBY MODEM AND 
  2686.                  C/30E, OR A SR(ON) NS(OFF) KGAB AND A REMOTE PSN
  2687. DCAC-350-180-( )                                                     6-8
  2688.  
  2689.           TABLE 6-1.  REMOTE-MODEM DCE INTERFACE CONNECTOR PINOUT
  2690.  
  2691.                                                                           
  2692.  
  2693.         Pin     EIA     CCITT       Name                  
  2694.                 ID      ID    
  2695.  
  2696. Mandatory
  2697.  
  2698.         1       FG                 Frame Ground      
  2699.         4       SD +    103        Send Data         
  2700.         22      SD -    103        Send Data         
  2701.         5       ST +    114        Send Timing       
  2702.         23      ST -    114        Send Timing       
  2703.         6       RD +    104        Receive Data      
  2704.         24      RD -    104        Receive Data      
  2705.         7       RS +    105        Request to Send        
  2706.         25      RS -    105        Request to Send
  2707.         8       RT +    115        Receive Timing         
  2708.         26      RT -    115        Receive Timing
  2709.         9       CS +    106        Clear to Send
  2710.         27      CS -    106        Clear to Send
  2711.         12      TR +    108.2      Terminal Ready         
  2712.         30      TR -    108.2      Terminal Ready
  2713.         17      TT +    113        Terminal Timing        
  2714.         35      TT -    113        Terminal Timing
  2715.         19      SG      102        Signal Ground          
  2716.         37      SC      102a       Send Common
  2717.  
  2718. Optional
  2719.  
  2720.         2       SI      112        Signaling Rate Indicator
  2721.         10      LL      141        Local Loopback
  2722.         11      DM +    107        Data Mode
  2723.         13      RR      109        Receiver Ready
  2724.         14      RL      140        Remote Loopback
  2725.         15      IC      125        Incoming Call
  2726.         16      SF/SR   126/111    Select Frequency/Signaling Rate 
  2727.                                    Selector          
  2728.         18      TM      142        Test Mode
  2729.         20      RC      102b       Receive Common
  2730.         28      IS      ---        Terminal In Service
  2731.         29      DM -    107        Data Mode
  2732.         31      RR -    109        Receiver Ready
  2733.         32      SS      116        Select Standby
  2734.         33      SQ      110        Signal Quality
  2735.         34      NS      ---        New Signal
  2736.         36      SB      117        Standby Indicator
  2737.  
  2738.                                                                           
  2739. DCAC-350-180-( )                                                     6-9
  2740.  
  2741.              TABLE 6-2.  KGAB - REMOTE C/30E CONNECTOR PINOUT
  2742.  
  2743.                                                                           
  2744.  
  2745.         Pin     EIA     CCITT      Name
  2746.                 ID      ID            
  2747.  
  2748. Mandatory
  2749.  
  2750.         1       FG                    Frame Ground           
  2751.         24      SD +    103           Send Data              
  2752.         25      SD -    103           Send Data
  2753.         4       ST +    114           Send Timing
  2754.         5       ST -    114           Send Timing
  2755.         6       RD +    104           Receive Data           
  2756.         7       RD -    104           Receive Data
  2757.         8       RT +    115           Receive Timing         
  2758.         9       RT -    115           Receive Timing
  2759.         10      TR +    108.2         Terminal Ready         
  2760.         11      TR -    108.2         Terminal Ready
  2761.         12      SG      102           Signal Ground          
  2762.         13      SC      102a          Send Common            
  2763.         19      SS      116           Select Standby
  2764.  
  2765. Optional
  2766.  
  2767.         14      CS +    106           Clear to Send
  2768.         15      CS -    106           Clear to Send
  2769.         22      LL      141           Local Loopback
  2770.         20      DL +    105           "D" Loop (Reserved)    
  2771.         21      DL -    105           "D" Loop (Reserved)
  2772.         18      RL      140           Remote Loopback
  2773.         2       TT +    113           Terminal Timing        
  2774.         3       TT -    113           Terminal Timing
  2775.         16      CL +    126           "C" Loop (KG-84A Loop)
  2776.         17      CL -    126           "C" Loop (KG-84A Loop)
  2777.  
  2778.                                                                           
  2779.  
  2780. DCAC-350-180-( )                                                     6-10
  2781.  
  2782.               TABLE 6-3  KGAB - REMOTE MODEM CONNECTOR PINOUT
  2783.  
  2784.                                                                           
  2785.  
  2786.         Pin     EIA     CCITT      Name
  2787.                 ID      ID         
  2788.  
  2789. Mandatory
  2790.  
  2791.         1       FG                 Frame Ground
  2792.         2       SD +    103        Send Data
  2793.         3       SD -    103        Send Data
  2794.         4       ST +    114        Send Timing
  2795.         5       ST -    114        Send Timing
  2796.         6       RD +    104        Receive Data
  2797.         7       RD -    104        Receive Data
  2798.         8       RT +    115        Receive Timing
  2799.         9       RT -    115        Receive Timing
  2800.         10      TR +    108.2      Terminal Ready
  2801.         11      TR -    108.2      Terminal Ready
  2802.         14      SG      102        Signal Ground
  2803.         15      SG      102        Signal Ground
  2804.         24      TT +    113        Terminal Timing
  2805.         25      TT -    113        Terminal Timing
  2806.  
  2807. Optional
  2808.  
  2809.         12      CS +    106        Clear To Send
  2810.         13      CS -    106        Clear To Send
  2811.         16      CL      ---        "C" Loop (KG-84A Loop)
  2812.         17      CL -    ---        "C" Loop (KG-84A Loop)
  2813.         18      RL +    140        Remote Loopback
  2814.         19      RL -    140        Remote Loopback
  2815.         20      DL +    ---        "D" Loop (Reserved)
  2816.         21      DL -    ---        "D" Loop (Reserved)
  2817.         22      LL +    141        Local Loopback
  2818.         23      LL -    141        Local Loopback
  2819.  
  2820.                                                                           
  2821.  
  2822. DCAC-350-180-( )                                                     6-11
  2823.  
  2824. 4.  Interconnecting Cables.   Figures 6-4 and 6-5 provide a cabling 
  2825. diagram of a configuration with a C/30E, modems, and FPAs.  Table 6-4 
  2826. describes the cables used for interconnecting these devices.  See chapter 
  2827. 1, section 4, for specifications on interconnecting cables.
  2828.  
  2829.  
  2830.                     TABLE 6-4. REMOTE INTERFACE CABLES
  2831.  
  2832.                                                                           
  2833.  
  2834. Connection             BBNCC         Description
  2835.                        P/N#
  2836.  
  2837. PSN IMP/MII to DPPE    2406833G01    12-pr, PSN/MSYNC 188-114 Bal
  2838.                                      Host to DB25P
  2839.  
  2840. DPPE to KGAB           2406817GO1    12-pr, DB25S to FPA-J1
  2841.  
  2842. KGAB to DPPC           2406812GO1    12-pr, FPA-J2 to DB25P
  2843.  
  2844. DPPC to DCE            2407835GO1    12-pr, DB25S to 188-114 DCE
  2845.  
  2846.                                                                           
  2847. DCAC-350-180-( )                                                     6-12
  2848.  
  2849.  
  2850. +------------------------------------------------------------------------+
  2851. |                                                                        |
  2852. |                                                                        |
  2853. |                                                                        |
  2854. |         Cable # +-+ Cable #                 Cable # +-+  Cable #       |
  2855. | +-----+2406833- | |2407835-                 2407835-| | 2406833-       |
  2856. | |C/30E|   G01   |D|  G01   +-----+   +-----+  G01   |D|   G01   +----+ |
  2857. | | PSN |---------|P|--------| DCE |---| DCE |--------|P|---------|DTE | |
  2858. | |(DTE)|         |P|        +-----+   +-----+        |P|         |HOST| |
  2859. | +-----+         |E|                                 |E|         +----+ |
  2860. |                 +-+                                 +-+                |
  2861. |                                                                        |
  2862. |                                                                        |
  2863. |                                                                        |
  2864. |                                                                        |
  2865. +------------------------------------------------------------------------+
  2866.  
  2867.             FIGURE 6-4.  C/30E AND REMOTE HOST CABLING DIAGRAM
  2868.  
  2869.  
  2870.  
  2871. +------------------------------------------------------------------------+
  2872. |                                                                        |
  2873. | +-----+                                                        +-----+ |
  2874. | |C/30E|                                                        |C/30E| |
  2875. | | PSN |                                                        | PSN | |
  2876. | |(DTE)|                                                        |     | |
  2877. | +--+--+                                                        +--+--+ |
  2878. |    | Cable #                                              Cable # |    |
  2879. |    | 2406833G01                                        2406833G01 |    |
  2880. | +--+--+                                                        +--+--+ |
  2881. | | DPPE|                                                        | DPPE| |
  2882. | +--+--+                                                        +--+--+ |
  2883. |    | Cable #                                              Cable # |    |
  2884. |    | 2406817G01                                        2406817G01 |    |
  2885. |    |                                                              |    |
  2886. |    |   Cable #      Cable #                 Cable #     Cable #   |    |
  2887. | +--+--+2406812-+-+ 2407835-                2407835- +-+2406812-+--+--+ |
  2888. | |     |  G01   |D|   G01  +-----+    +-----+  G01   |D|  G01   |     | |
  2889. | | KGAB|--------|P|--------| DCE |----| DCE |--------|P|--------| KGAB| |
  2890. | |     |        |P|        +-----+    +-----+        |P|        |     | |
  2891. | +-----+        |C|                                  |C|        +-----+ |
  2892. |                +-+                                  +-+                |
  2893. |                                                                        |
  2894. |                                                                        |
  2895. +------------------------------------------------------------------------+
  2896.  
  2897.             FIGURE 6-5.  C/30E AND REMOTE TRUNK CABLING DIAGRAM
  2898.                          (WITH CRYPTOGRAPHIC DEVICES)
  2899.  
  2900. DCAC-350-180-( )                                                     7-1
  2901.  
  2902.          CHAPTER 7.  EIA-232-D NEIGHBOR OR NEARBY TRUNK INTERFACE
  2903.  
  2904. 1.  Overview.  This chapter describes the electrical and mechanical 
  2905. characteristics of the obsolete DDN EIA-232-D  PSNconnection at the 
  2906. neighbor or nearby PSN.   DDN supports Extended Modem Looping (XMOD) 
  2907. through the EIA-232-D interface. For ease of reference, Table 7-1 equates 
  2908. the EIA-232-D, EIA-449, and CCITT interface signal names.  However, in the 
  2909. rest of this chapter, only the EIA-232-D signal name will be used.  DDN 
  2910. uses the EIA-232-D interface only where an existing non-DDN standard PSN 
  2911. provides such an interface, and it is not feasible to install a 
  2912. MIL-STD-188-114 balanced interface prior to upgrading the entire node to 
  2913. DDN standard (MIL-STD-188-114 balanced serial trunk interfaces).
  2914.  
  2915. 2.  Electrical Characteristics.
  2916.  
  2917.     a.  Voltage Levels.  The electrical measurements of the C/30E 
  2918. EIA-232-D interface circuits are in accordance with EIA Standard 232-D, 
  2919. section 2.1.  For normal operation, the open circuit driver voltage shall 
  2920. be no more than +15 V.
  2921.  
  2922.     b.  Clocking.
  2923.  
  2924.         (1)  Supported Clock Rates.  The MMR fantail contains the
  2925. DCAC-350-180-( )                                                     7-2
  2926.  
  2927. connector that terminates a cable from all the DTE.  The fantail contains 
  2928. one EIA-232-D connector configured as a DTE.  This interface has no 
  2929. clock-sourcing capability.  The hardware can support external clock rates 
  2930. between 1.2 kb/s and 112 kb/s.  However, DDN policy is 9.6 kb/s for the 
  2931. minimum  PSN bit rate and 19.2 kb/s for the maximum rate.
  2932.  
  2933.         (2)  Signaling Sense.   Signaling sense is in accordance with EIA 
  2934. Standard 232-D, subsection 2.1.3.  The signal is considered marking (OFF) 
  2935. when the voltage on the interchange circuit is more negative than -3 V 
  2936. with respect to signal ground, and spacing (ON) when the voltage is more 
  2937. positive than +3 V with respect to signal ground.
  2938.  
  2939.     c.  Bit Rate and Cable Length.  Interconnecting cable length  is in 
  2940. accordance with EIA-232-D, section 3.1.  The recommended maximum cable 
  2941. length between an EIA-232-D DCE and DTE is 200 feet when overall shielded, 
  2942. low capacitance, twisted pair cable is used.
  2943.  
  2944.     d.  Interchange  Circuits.
  2945.  
  2946.         (1)  Electrical Use of Interchange Circuits.  The DDN electrical 
  2947. use of interchange circuits is either static or active.  Static circuits 
  2948. are tied by the hardware so that the signal state remains constant on the 
  2949. line, either ON or OFF.  Active circuits change their state under program 
  2950. control.  DDN use of the interchange circuits is shown in Table 7-2.
  2951.  
  2952. DCAC-350-180-( )                                                     7-3
  2953.  
  2954.                  TABLE 7-1.  SIGNAL NAME EQUIVALENCY TABLE
  2955.  
  2956.                                                                           
  2957.  
  2958.  
  2959. EIA-232-D                                      EIA-449                        CCITT
  2960. ID          Name                               ID     Name                    ID     Name
  2961.  
  2962. AB         Signal Ground                       SG     Signal Ground           102    Signal Ground
  2963. CE         Ring Indicator                      IC     Incoming Call           125    Calling Indicator
  2964. CD         DTE Ready                           TR     Terminal Ready          108/2  Data Terminal Ready
  2965. CC         DCE Ready                           DM     Data Mode               107    Data Set Ready
  2966. BA         Transmitted Data                    SD     Send Data               103    Transmitted Data
  2967. BB         Received Data                       RD     Receive Data            104    Received Data
  2968. DA         Transmitter Signal Element Timing   TT     Terminal Timing         113    Transmitter Signal Element
  2969.             (DTE Source)                                                              Timing (DTE Source)
  2970. DB         Transmitter Signal Element Timing   ST     Send Timing             114    Transmitter Signal Element
  2971.             (DCE Source)                                                              Timing (DCE Source)
  2972. DD         Receiver Signal Element Timing      RT     Receive Timing          115    Receiver Signal Element
  2973.             (DCE Source)                                                              Timing (DCE Source)
  2974. CA         Request To Send                     RS     Request To Send         105    Request To Send
  2975. CB         Clear To Send                       CS     Clear To Send           106    Ready For Sending
  2976. CF         Received Line Signal Detector       RR     Receiver Ready          109    Data Channel Received Line
  2977.                                                                                       Signal Detector
  2978. CG         Signal Quality Detector             SQ     Signal Quality          110    Data Signal Quality
  2979.                                                                                       Detector
  2980. CH         Data Signal Rate Selector           SR     Signaling Rate Selector 111    Data Signaling Rate
  2981.             (DTE Source)                                                              Selector (DTE Source)
  2982. CI         Data Signal Rate Selector           SI     Signaling Rate          112    Data Signaling Rate
  2983.             (DCE Source)                               Indicator                      Selector (DCE Source)
  2984. LL         Local Loopback                      LL     Local Loopback          141    Local Loopback
  2985. RL         Remote Loopback                     RL     Remote Loopback         140    Remote Loopback
  2986. TM         Test Mode                           TM     Test Mode               142    Test Indicator
  2987.  
  2988.  
  2989.                                                                           
  2990. DCAC-350-180-( )                                                     7-4
  2991.  
  2992.         (2)  Software Use of Interchange Circuits.  Interchange circuit 
  2993. signals are used by the software in different ways.  Active circuits are 
  2994. under program control: either the software reacts to a received signal 
  2995. when it changes, or the software can assert a transmitted signal when 
  2996. necessary (such as LL which can be used by operations personnel for 
  2997. testing connections).  Unsupported circuits are either not read by the 
  2998. software or a value is written to the circuit by the software, and that 
  2999. value does not change during operation.  Table 7-2 provides a list of 
  3000. circuits and their use.
  3001.  
  3002.         (3)  Interchange Circuit Definitions.
  3003.  
  3004.              (a)  Signal Ground.  See EIA Standard 232-D.
  3005.  
  3006.              (b)  DCE Ready.  This circuit is not monitored by the PSN 
  3007. software.
  3008.              (c)  DTE Ready.  This circuit is asserted OFF by PSN software 
  3009. when the link is initialized.  Available for Monitoring Center control.
  3010.  
  3011.              (d)  Transmitted Data.  See EIA Standard 232-D.
  3012.  
  3013.              (e)  Received Data.  See EIA Standard 232-D.
  3014.  
  3015.              (f)  Transmitter Signal Element Timing (DCE Source).  See EIA 
  3016. Standard 232-D.  This circuit provides the clock for Transmitted Data when 
  3017. the DCE sources timing.
  3018.  
  3019.  
  3020. DCAC-350-180-( )                                                     7-5
  3021.  
  3022.              (g)  Receiver Signal Element Timing (DCE Source).  See EIA 
  3023. Standard 232-D.  This circuit provides clock for Received Data when the 
  3024. DCE sources timing.
  3025.  
  3026.              (h)  Request to Send.  This circuit is asserted OFFby  PSN  
  3027. software  when the link is  initialized.  Available  for Monitoring Center 
  3028. control.
  3029.  
  3030.              (i)  Clear to Send.  This circuit must be asserted ON by the 
  3031. DCE, but it is not monitored by the PSN software.
  3032.  
  3033.              (j)  Received Line Signal Detector.  This circuit must  be 
  3034. asserted ON by the DCE, but it is not monitored by  the PSN software.
  3035. DCAC-350-180-( )                                                     7-6
  3036.  
  3037.             TABLE 7-2. EIA-232-D INTERCHANGE TRUNK CIRCUIT USE
  3038.  
  3039.                                                                           
  3040.  
  3041.  
  3042. 232                                               Electrical       Required State of   Comments
  3043. ID     EIA-232-D Name         Source              State         Control/Status Signals
  3044.  
  3045. AB     Signal Ground          DTE/DCE             Ground                 N/A*          
  3046. BA     Transmitted Data       DTE                 Active                 N/A           Data Circuit
  3047. BB     Received Data          DCE                 Active                 N/A           Data Circuit
  3048. CA     Request to Send        DTE                 Active                 OFF           Asserted OFF by PSN software.
  3049.                                                                                        Treated as LL for XMOD.
  3050. CB     Clear to Send          DCE                 Active                 Don't Care    Not monitored by PSN software.
  3051. CC     DCE Ready              DCE                 Active                 Don't Care    Not monitored by PSN software.
  3052. CD     DTE Ready              DTE                 Active                 OFF           Asserted OFF by PSN software.
  3053.                                                                                        Treated as RL for XMOD.
  3054. CF     Received Line Signal   DCE                 Active                 Don't Care    Not monitored by PSN software.
  3055. DB     Transmitter Signal     DCE                 Active                 N/A           Timing circuit for Transmitted
  3056.                                                                                        Data when the DCE supplies
  3057.                                                                                        timing 
  3058. DD     Receive Signal         DCE                 Active                 N/A           Timing circuit used for
  3059.         Element Timing                                                                 Received Data when the DCE supplies
  3060.                                                                                        timing.
  3061.                                                                                        No action is taken.
  3062.  
  3063.  
  3064.                                                                           
  3065.  
  3066. * N/A = Not Applicable
  3067. DCAC-350-180-( )                                                     7-7
  3068.  
  3069. 3.  Mechanical Characteristics.  The MMR EIA-232-D connectors on the C/30E 
  3070. meets the specifications provided in this section.
  3071.  
  3072.     a.  Interface Connectors.  The MMR C/30E fantail EIA-232-D connector 
  3073. is a DB-25P type (male) connectors.  Intermating dimensions are in 
  3074. accordance with EIA-232-D, section 3.2.1.
  3075.  
  3076.     b.  Connector Contact Assignments.  DDN standard node EIA-232-D 
  3077. connector contact assignments are in accordance with EIA-232-D, section 
  3078. 3.3.1.  Table 7-3 provides DDN EIA-232-D connector pin assignments.  
  3079. Signal use is specified in section 2.d.3. of this Standard.
  3080. DCAC-350-180-( )                                                     7-8
  3081.  
  3082.                   TABLE 7-3.  EIA-232-D CONNECTOR PINOUT
  3083.  
  3084.                                                                           
  3085.  
  3086. Pin     EIA     CCITT         Name
  3087.         ID      ID            
  3088.  
  3089. 1       --      --            Shield
  3090. 2       BA      103           Transmitted Data
  3091. 3       BB      104           Received Data
  3092. 4       CA      105           Request To Send
  3093. 5       CB      106           Clear To Send
  3094. 6       CC      107           DCE Ready
  3095. 7       AB      102           Signal Ground (Common Return)
  3096. 8       CF      109           Received Line Signal Detector
  3097. 9       --      ---           + DC Test Voltage (+8VDC)
  3098. 10      --      ---           - DC Test Voltage (-8VDC)
  3099. 11      DB      114           Transmitted Signal Element Timing
  3100.                                (DCE Source)
  3101. 12      DD      115           Receiver Signal Element Timing
  3102.                                (DCE Source)
  3103. 13      CD      108/2         DTE Ready
  3104.  
  3105.                                                                           
  3106.  
  3107. * The circuit name "DC" is from and earlier version of EIA-232.
  3108.  
  3109. DCAC-350-180-( )                                                     7-9
  3110.  
  3111. 4.  Interconnecting Cables.
  3112.  
  3113.     a.  For interconnecting cable specifications,  see chapter 1 and 
  3114. section 4, of this guide.
  3115.  
  3116.     b.  Figure 7-1 is a cabling diagram of a C/30E PSN connected to a 
  3117. nearby EIA-232 PSN, and figure 7-2 is an example of an interconnecting 
  3118. cable (BBNCC P/N# 2405535GO1).
  3119.  
  3120.  
  3121.  
  3122.  
  3123.    +------------------------------------------------------------------+
  3124.    |                                                                  |
  3125.    |             DB-25S                            DB-25S             |
  3126.    |               /                                  \               |
  3127.    | +--------+  /                +-----+               \  +--------+ |
  3128.    | |EIA-232 |--+ 2405535G01  +--|RS232|--+ 2405535G01 +--|EIA-232 | |
  3129.    | | C/30E  |P1|=============|P2| SME |P1|============|P2| C/30E  | |
  3130.    | |  PSN   |--+             +--|     |--+            +--|  PSN   | |
  3131.    | | (DTE)  |                /  +-----+  \               | (DTE)  | |
  3132.    | +--------+              /               \             +--------+ |
  3133.    |                     DB-25P            DB-25P                     |
  3134.    |                                                                  |
  3135.    +------------------------------------------------------------------+
  3136.  
  3137.       FIGURE 7-1.  C/30E PSN AND NEARBY EIA-232-D PSN CABLING DIAGRAM
  3138. DCAC-350-180-( )                                                     8-1
  3139.  
  3140.                   CHAPTER 8.  V.35 REMOTE TRUNK INTERFACE
  3141.  
  3142. 1.  Overview.  This chapter describes the electrical and mechanical  
  3143. characteristics of the obsolete DDN V.35 connection between two remote 
  3144. PSNs.  DDN standard does not support neighbor or nearby V.35 PSN-PSN 
  3145. connections.   Like the EIA-232 interface, the V.35 interface is used only 
  3146. where an existing non-DDN-standard PSN provides such an interface, and it 
  3147. is not feasible to install a MIL-STD-188-114 balanced interface prior to 
  3148. upgrading the entire node to DDN-standard (MIL-STD-188-114 balanced serial 
  3149. PSN interfaces). All control signals have electrical characteristics of 
  3150. EIA-232-D, and EIA-232-D signal names are used in the rest of this 
  3151. chapter.  The data and timing signals conform to Recommendation V.35. DDN 
  3152. supports Extended Modem Looping (XMOD) through the V.35 interface.
  3153.  
  3154. 2.  Electrical Characteristics.
  3155.  
  3156.      a.  Voltage Levels.  The electrical measurements of the C/30E V.35 
  3157. interface circuits are in accordance with CCITT Recommendation V.35.
  3158.  
  3159.      b.  Clocking.  The MMV interface hardware contains the connectors 
  3160. that terminate the cables from all I/O interfaces.  The MMV fantail 
  3161. contains one V.35 connector configured as a DTE.  This interface has no 
  3162. clock-sourcing capability.  The hardware  can support external clock rates 
  3163. between 300 b/s and 100 kb/s.
  3164. DCAC-350-180-( )                                                     8-2
  3165.  
  3166.          (1)  Signaling Sense.  Signaling sense is in accordance with 
  3167. CCITT Recommendation V.35.  A binary "0" (space) is transmitted when 
  3168. terminal "A" is positive (+.55v +20%) to terminal "B" (-.55V +20%).  A 
  3169. binary 1 is transmitted when terminal "A" is negative (-.55v +20%) to 
  3170. terminal "B" (+.55v +20%).  The drivers produce a nominal 1.1 volts 
  3171. peak-to-peak signal balanced with respect to ground.
  3172.  
  3173.      c.  Bit Rate/Cable Length.
  3174.  
  3175.          (1)  Maximum Cable Length.  The recommended maximum cable length 
  3176. between a V.35 DCE and DTE is 30 feet when overall shielded, low 
  3177. capacitance, twisted pair cable is used.  Cable  lengths  of  up to 2000 
  3178. feet are also  possible with the proper cables, see LOR-0023-003 for more 
  3179. details.
  3180.  
  3181.      d.   Interchange  Circuits.
  3182.  
  3183.           (1)  Electrical Use of Interchange Circuits.  The DDN electrical 
  3184. use of interchange circuits is either static or active.  Static circuits 
  3185. are tied by the hardware so that the signal state remains constant on the 
  3186. line, either ON or OFF.  Active circuits change their state under program 
  3187. control.  DDN use of the interchange circuits is shown in Table 8-1.
  3188.  
  3189.           (2)  Software Use of Interchange Circuits.  Interchange circuit 
  3190. signals are used by the software in different ways.  Active circuits are 
  3191. DCAC-350-180-( )                                                     8-3
  3192.  
  3193. under program control: either the software reacts to the circuit signal 
  3194. when it changes, or the software can assert a circuit when necessary (such 
  3195. as LL which can be used by operations personnel for testing connections).  
  3196. Unsupported circuits either are not read by the software or a value is 
  3197. written to the circuit by the software, and that value does not change 
  3198. during operation.  Table 8-1 describes circuit use.
  3199.  
  3200.           (3)  Interchange Circuit Definitions.  EIA-232-D signal names 
  3201. are used throughout this chapter.
  3202.  
  3203.                (a)  Signal Ground.  See EIA-232-D.
  3204.  
  3205.                (b)  DCE Ready.  This circuit must be asserted ON by the 
  3206. DCE, but it is not monitored by the PSN software.
  3207.  
  3208.                (c)  Transmitted Data.  See EIA-232-D.
  3209.  
  3210.                (d)  Received Data.  See EIA-232-D.
  3211.  
  3212.                (e)  Transmitter Signal Element Timing (DTE Source).  See 
  3213. EIA-232-D.  Also see subsection 2.b of this guide.  This circuit provides 
  3214. the clock for Transmitted Data when the PSN sources timing.  The frequency 
  3215. of this circuit is equal to that of Transmitter Signal Element Timing.
  3216.  
  3217.                (f)  Transmitter Signal Element Timing (DCE Source).  See  
  3218. EIA-232-D.   This  circuit  optionally provides the clock for Transmitted 
  3219. Data when the DCE sources timing.
  3220. DCAC-350-180-( )                                                     8-4
  3221.  
  3222.                (g)  Receive Signal Element Timing (DCE).  This circuit  
  3223. optimally provides the clock for received data when the DCE sources 
  3224. timing.
  3225.  
  3226.                (h)  Request to Send.  This circuit is asserted OFF by the 
  3227. PSN software. Available for Monitoring Center control.
  3228.  
  3229.                (i)  Clear to Send.  This circuit must be asserted ON by 
  3230. the DCE, but it is not monitored by PSN software.
  3231.  
  3232.                (j)  Received Line Signal Detector.  This circuit must be 
  3233. asserted ON by the DCE, but it is not monitored by PSN software.
  3234.  
  3235.                (k)  Data Terminal Ready.  This circuit is asserted OFF by 
  3236. the PSN software. Available for Monitoring Center control.
  3237.  
  3238.                (l)  Local Test Loopback.  This circuit is asserted OFF by 
  3239. the PSN software. Available for Monitoring Center control.
  3240.  
  3241. DCAC-350-180-( )                                                     8-5
  3242.  
  3243.                TABLE 8-1. V.35 TRUNK INTERCHANGE CIRCUIT USE
  3244.  
  3245.                                                                           
  3246.  
  3247.  
  3248. CCITT                                             Electrical       Required State of    Comments
  3249. ID     Name                       Source          State         Control/Status Signals
  3250.  
  3251. 101    Protective Ground          DTE/DCE         Ground                N/A                   
  3252. 102    Signal Ground              DCE/DTE         Ground                N/A
  3253. 103    Transmitted Data           DTE             Active                N/A                   Data Circuit
  3254. 104    Received Data              DCE             Active                N/A                   Data Circuit
  3255. 105    Request to Send            DTE             Active                OFF                   Asserted OFF by PSN software.
  3256.                                                                                               Treated as LL for XMOD.
  3257. 106    Clear to Send              DCE             Active                ON                    Not monitored by PSN software.
  3258. 107    DCE Ready                  DCE             Active                Don't Care            Not monitored by PSN software.
  3259. 108/2  DTE Ready                  DTE             Active                OFF                   Asserted OFF by PSN software.
  3260.                                                                                               Treated as RL for XMOD.
  3261. 109    Received Line              DCE             Active                ON                    Not monitored by PSN software.
  3262. 113    Transmitter Signal         DTE             Active                N/A                   Reflected timing circuit
  3263.         Element Timing                                                                        for Transmitted Data
  3264.                                                                                               timing.
  3265. 114    Transmitter Signal         DCE             Active                N/A                   Timing circuit for Transmitted
  3266.         Element Timing                                                                        Data when the DCE supplies
  3267.                                                                                               timing.
  3268. 115    Receiver Signal            DCE             Active                N/A                   Timing circuit for Received
  3269.         Element Timing                                                                        Data when the DCE supplies
  3270.                                                                                               timing.
  3271. 141    Local Test                 DCE             Active                OFF                   Asserted OFF by PSN software.
  3272.         Loopback                                                                              Treated as CL by XMOD.
  3273.  
  3274.  
  3275.                                                                           
  3276.  
  3277. NOTES:  N/A = Not Applicable
  3278.  
  3279. DCAC-350-180-( )                                                     8-6
  3280.  
  3281. 3.  Mechanical Characteristics.  All V.35 connectors offered for the C/30E 
  3282. meet the specifications provided in this section.  Cables for this 
  3283. interface, supplied by DDN, are equipped with an EIA-449 connector on one 
  3284. end to mate with the EIA-449 connector on the C/30E fantail; the other end 
  3285. provides a MIL-C-28748 34-pin connector to mate with the V.35 DCE.
  3286.  
  3287.     a.  Interface Connectors.  The V.35 connectors on the C/30E fantail is 
  3288. a DC-37P type (male) connector.  It is wired as described in Table 8-2.
  3289.  
  3290.         (1)  Intermating dimensions are in accordance with EIA-449-D.
  3291.  
  3292.         (2)  The means for C/30E DTE connectors to latch and unlatch from 
  3293. the latching blocks on the DCE connector are within the dimensions 
  3294. specified in EIA-449, section 3.3.1.  DDN uses the English 4-40 thread 
  3295. latching block.
  3296.  
  3297.     b.  Connector Contact Assignments.  DDN standard node V.35 connector 
  3298. contact assignments are in accordance with CCITT Recommendation V.35 and 
  3299. ISO 2593.  Table 8-2 provides DDN V.35 connector pin assignments.  The 
  3300. signals are used as specified in section 2.d.3.
  3301.  
  3302. DCAC-350-180-( )                                                     8-7
  3303.  
  3304.             TABLE 8-2.  V.35 34-PIN AND 37-PIN CONNECTOR PINOUT
  3305.  
  3306.                                                                           
  3307.  
  3308. 34-pin   37-pin*  CCITT  Signal Name                      449
  3309.  #         #      ID                                      Name
  3310.  
  3311. A        1        101    Shield                           FG
  3312. P        4        103    Transmitted Data                 SD+
  3313. S        22       103    Transmitted Data                 SD-**
  3314. Y        5        114    Transmitter Signal Element       ST+
  3315.                           Timing (DCE Source)
  3316. a/AA     23       114    Transmitter Signal Element       ST-
  3317.                           Timing (DCE Source)
  3318. R        6        104    Received Data                    RD+
  3319. T        24       104    Received Data                    RD-
  3320. V        8        115    Receiver Signal Element Timing   RT+
  3321.                           (DCE Source)
  3322. X        26       115    Receiver Signal Element Timing   RT-
  3323.                           (DCE Source)
  3324. H        30       108/2  DTE Ready                        TR
  3325. B        12       102    Signal Ground                    SG
  3326. C         7       105    Request to Send                  RS
  3327. B***     25       102    Signal Ground                    SG
  3328. K        10       141    Local Test Loopback              LL(LT)
  3329. B        28       102    Signal Ground                    SG
  3330. U        17       113    Transmitter Signal Elem Timing   SG-
  3331.                           (DTE Source)
  3332. W        35       113    Transmitter Signal Elem Timing SG-
  3333.                           (DTE Source)
  3334. E        11       107    DCE Ready                        RR
  3335. B        29       102    Signal Ground                    SG
  3336. D        9        106    Clear to Send                    CS
  3337. B****    27       102    Signal Ground                    SG
  3338. F        13       109    Received Ready                   RR
  3339. B        31       102    Signal Ground                    SG
  3340. B        19       102    Signal Ground                    SG
  3341. B        37       102    Signal Ground                    SG
  3342.  
  3343.                                                                           
  3344.  
  3345. * This information represents a straight cable to a V.35 DCE.
  3346. ** The + and - symbols, used in EIA-449, correspond to A and B,
  3347.    respectively, in V.35 terminology.
  3348. *** Internally reflected clocks are supplied on pins TT.
  3349. **** V.35 in 34 pin connector is labeled as pin B Signal Ground.
  3350.  
  3351. DCAC-350-180-( )                                                     8-8
  3352.  
  3353. 4.  Interconnecting Cables.
  3354.  
  3355.     (a)  For interconnecting cable specifications, see chapter 1, section 
  3356. 4, of this guide.
  3357.  
  3358.     (b)  Figure 8-1 is a cabling diagram of a V.35 PSN and remote V.35 
  3359. PSN, and figure 8-2 provides an example of an interconnecting cable (BBNCC 
  3360. P/N# 2405510G01). 
  3361.  
  3362.  
  3363.  
  3364.  
  3365.  
  3366.  
  3367.   +------------------------------------------------------------------+
  3368.   |                                                                  |
  3369.   |            V.35P                              DC-37P             |
  3370.   |              /                                    \              |
  3371.   | +-------+  /            +-----+  +-----+            \  +-------+ |
  3372.   | |  V.35 |--+ 2405540G01 |     |  |     | 2405540G01 +--|  V.35 | |
  3373.   | | C/30E |P1|========================================|P2| C/30E | |
  3374.   | | (DTE) |--+            | DCE |  | DCE |            +--| (DTE) | |
  3375.   | +-------+               +-----+  +-----+               +-------+ |
  3376.   |                                                                  |
  3377.   +------------------------------------------------------------------+
  3378.  
  3379.         FIGURE 8-1.  C/30E PSN AND REMOTE V.35 PSN CABLING DIAGRAM
  3380.  
  3381. DCAC-350-180-( )                                                     8-9
  3382.  
  3383.  
  3384.        +-----------------------------------------------------------+
  3385.        |      C/30E                                       C/30E    |
  3386.        |        P1                                         P2      |
  3387.        |      DC-37S                                      DC-37S   |
  3388.        | Pin#     Signal                            Signal    Pin# |
  3389.        |  +/-       +/-   Shield             Shield   +/-      +/- |
  3390.        |  1         FG  >--------+         +-------<  FG       1   |
  3391.        |                                                           |
  3392.        |                                                           |
  3393.        |  P/S       SD   Pair #                       SD      4/22 |
  3394.        |                >-(1)----------------------<               |
  3395.        |  Y/AA      ST                                ST      5/23 |
  3396.        |                >-(2)----------------------<               |
  3397.        |  R/T       RD                                RD      6/24 |
  3398.        |                >-(3)----------------------<               |
  3399.        |  V/X       RT                                RT      8/26 |
  3400.        |  H/B       TR  >-(4)----------------------<  TR     30/12 |
  3401.        |                                                           |
  3402.        |  C/B       RS  >-(5)----------------------<  RS      7/25 |
  3403.        |  K/B       LL                                LL     10/28 |
  3404.        |                >-(6)----------------------<               |
  3405.        |  U/W       TT                                TT     17/35 |
  3406.        |                >-(7)----------------------<               |
  3407.        |  E/B                                         DM     11/29 |
  3408.        |                >-(8)----------------------<               |
  3409.        |  D/B       OS                                CS      9/27 |
  3410.        |            DM  >-(9)----------------------<               |
  3411.        |  F/B       RR                                RR     13/31 |
  3412.        |                >-(10)---------------------<               |
  3413.        |  B/B       SG                                SG     19/37 |
  3414.        |                >-(11)---------------------<               |
  3415.        |                                                           |
  3416.        |                >-(12)---------------------<               |
  3417.        |                                                           |
  3418.        +-----------------------------------------------------------+
  3419.      
  3420.         FIGURE  8-2.  CABLE EXAMPLE:  C/30E PSN TO REMOTE V.35 PSN
  3421.  
  3422. DCAC-350-180-( )                                                     9-1
  3423.  
  3424.           CHAPTER 9. BELL 303  NEIGHBOR OR NEARBY TRUNK INTERFACE
  3425.  
  3426. 1.  Overview.  This chapter describes the electrical and mechanical 
  3427. characteristics of the BELL 303 DTE interface that connects the C/30E PSN 
  3428. with a modem. This interface is in conformance with the  BELL 303 
  3429. standard, cited in chapter of this guide.  The BELL 303 interface is used 
  3430. only where an existing non-DDN-standard PSN provides such an interface, 
  3431. and it is not feasible to install a MIL-STD-188-114 balanced interface 
  3432. prior to upgrading the entire node to DDN-standard (MIL-STD-188-114 
  3433. balanced serial PSN interfaces). DDN supports Extended Modem Looping 
  3434. (XMOD) through the BELL 303 interface. For ease of reference, table 9-1 
  3435. equates the EIA-449, BELL 303, and CCITT interface signal names.  In the 
  3436. remainder of the BELL 303 discussion, the EIA-449 signal name will be 
  3437. used.
  3438.  
  3439. 2.  Electrical Characteristics.
  3440.  
  3441.     a.  Voltage Levels and Signaling Sense.  The electrical measurements 
  3442. of the C/30E interface circuits are in accordance with Bell 303.  The 
  3443. cable drivers operate into, and the cable terminators operate from coaxial 
  3444. cables, with 75 ohms to  120 ohms characteristic impedance.  The high 
  3445. speed interface is provided on a current switching basis. A binary "1", 
  3446. Control "OFF" or "marking" signal is represented by a current less than 5 
  3447. DCAC-350-180-( )                                                     9-2
  3448.  
  3449. ma into 100 ohms.  A binary "0", Control "ON" or "spacing" signal is 
  3450. represented by a current greater than 23 ma into 100 ohms.  All 
  3451. interchange circuits are fail-safe in that an open circuit is considered a 
  3452. control OFF or Mark Hold condition.
  3453.  
  3454. The above-mentioned currents are supplied at the output of the cable 
  3455. drivers.  The open circuit voltage of the terminator will range between 
  3456. -1.3 and -0.8 volts. The negative voltage is added by a bias in the 
  3457. terminator.  With greater than 23 ma into 100 ohms supplied to a cable 
  3458. terminator, the terminator input voltage is more positive than +1.0 
  3459. volts.  An open circuit must be recognized by a terminator as OFF, as 
  3460. mentioned above.
  3461. DCAC-350-180-( )                                                     9-3
  3462.  
  3463.                  TABLE 9-1.  SIGNAL NAME EQUIVALENCY TABLE
  3464.  
  3465.                                                                           
  3466.  
  3467.  
  3468. EIA-449                                  BELL 303                                  CCITT
  3469. ID    Name                               ID     Name                               ID     Name
  3470.  
  3471. SG    Signal Ground                      --     Ground in Sleeves                  102    Signal Ground
  3472. SC    Send Common                        --                                        102a   DTE Common
  3473. RC    Receive Common                     --                                        102b   DCE Common
  3474. SD    Send Data                          E      Send Data                          103    Transmitted Data
  3475. RD    Receive Data                       K      Received Data                      104    Received Data
  3476. RS    Request To Send                                                              105    Request To Send
  3477. CS    Clear To Send                                                                106    Ready For Sending
  3478. DM    Data Mode                                                                    107    Data Set Ready
  3479. TR    Terminal Ready                                                               
  3480.                                                                                    108/2  Data Terminal Ready
  3481. RR    Receiver Ready                                                               109    Data Channel Received Line
  3482.                                                                                            Signal Detector
  3483. IS    Terminal In Service                --                                        ---
  3484. SR    Signaling Rate Selector                                                      111    Data Signaling Rate
  3485.                                                                                            Selector (DTE Source)
  3486. SI    Signaling Rate                                                               112    Data Signaling Rate
  3487.        Indicator                                                                           Selector (DCE Source)
  3488. NS    New Signal                         --                                        ---
  3489. TT    Terminal Timing                                                              113    Transmitter Signal Element
  3490.                                                                                            
  3491. ST    Send  Timing                       J   Serial Clock                          114    Transmitter Signal Element
  3492.                                               Transmit                                     Timing (DCE Source)
  3493. RT    Receive  Timing                    L   Serial Clock Receive                  115    Receiver Signal Element
  3494.                                               (DCE Source)                                 Timing (DCE Source)
  3495. SS    Select Standby                     --                                        116    Select Standby
  3496. SF    Select Frequency                   --                                        126    Select Transmit Frequency
  3497. LL    Local Loopback                     G   Local Test                            141    Local Loopback
  3498. RL    Remote Loopback                                                              140    Remote Loopback
  3499.  
  3500.  
  3501.                                                                           
  3502.  
  3503. DCAC-350-180-( )                                                     9-4
  3504.  
  3505.     b.  Clocking.  Two fantails, MMI and MML, provide the connectors that 
  3506. terminate cables from all I/O interfaces.  The MMI fantail connector is 
  3507. configured as a DTE.  When the MMI fantail is used, the DCE must provide 
  3508. clock because the MMI fantail does not support clock-sourcing capability.  
  3509. The MML, a clock-sourcing enhanced fantail, is configured as a DCE and 
  3510. provides clock.
  3511.  
  3512.         (1)  MML Clock Rates.  MML and MMI interface hardware support any 
  3513. external clock between  1.2 kb/s and 112 kb/s.  However, DDN policy states 
  3514. that the minimum  PSN bit rate be 9.6 kb/s.  When MML clock-sourcing 
  3515. capability  is used, the MML on-board clock generator provides the 
  3516. following frequencies: 230.4 kb, 50 kb, 19.2 kb.  The 230.4 kb rate is not 
  3517. supported by operational software.
  3518.  
  3519.         (2)  Maximum Cable Length. The maximum length of the cable is 50 
  3520. feet. The MMI-configured PSN connector has a DC-37P type  (male) as the 
  3521. DTE and the  MML-configured  PSN  connector has a DC-37S (female) as the 
  3522. DCE.  Cable lengths greater than 200 feet may be possible.  The BELL 303 
  3523. specification, section 7, should be consulted.
  3524.  
  3525.      d.  Interchange Circuits.  The BELL 303 interface is provided by the 
  3526. MMI motherboard upon which is attached an MMI/MML daughterboard.
  3527.  
  3528.          (1)  Electrical Use of Interchange Circuits.  The DDN electrical 
  3529. use of interchange circuits is either static or active.  Static circuits 
  3530. are tied by the hardware so that the signal state remains constant on the 
  3531. DCAC-350-180-( )                                                     9-5
  3532.  
  3533. line, either ON or OFF. Active circuits change their state under program 
  3534. control.  DDN use of the interchange circuits is shown in table 9-2.
  3535.  
  3536.         (2)  Software Use of Interchange Circuits.  Interchange circuit 
  3537. signals are used by the software in different ways.  Active circuits are 
  3538. under program control: the software can react to a received signal when it 
  3539. changes, and the software can assert a transmitted signal when necessary 
  3540. (such as LL, which can be used by operations personnel for testing 
  3541. connections).  Unsupported circuits either are not read by the software or 
  3542. a value is written to the circuit by the software.  That value does not 
  3543. change during operation.  Table 9-2 provides a list of circuits and their 
  3544. use.
  3545.  
  3546.         (3)  Interchange Circuit Definitions.  For additional information 
  3547. about these interchange circuits, see EIA Standard 449.  The following 
  3548. descriptions assume use of full period/full duplex circuits, with flow 
  3549. control handled at higher levels.
  3550.  
  3551.              (a)  Signal Ground.  See EIA Standard 449.
  3552.  
  3553.              (b)  Send Data.  See EIA Standard 449.
  3554.  
  3555.              (c)  Receive Data.  See EIA Standard 449.
  3556.  
  3557.              (d)  Send Timing.  See EIA Standard 449.
  3558.  
  3559.              (e)  Receive Timing.  See EIA Standard 449.
  3560.  
  3561. DCAC-350-180-( )                                                     9-6
  3562.  
  3563.              (f)  Local Loopback.  LL is asserted OFF by PSN software when 
  3564. the link is initialized.   LL can be controlled by the Monitoring Center.
  3565. DCAC-350-180-( )                                                     9-7
  3566.  
  3567.              TABLE 9-2. BELL 303 TRUNK INTERCHANGE CIRCUIT USE
  3568.  
  3569.                                                                           
  3570.  
  3571.  
  3572. 449                               Electrical       Required State of   Comments
  3573. ID     EIA-449 Name     Source    Circuit       Control/Status Signals
  3574.  
  3575. SG     Signal  Ground   DTE/DCE   Ground in Sleeve        N/A            Ground
  3576. SD     Send Data        DTE       Active                  N/A            Data Circuit
  3577. RD     Receive Data     DCE       Active                  N/A            Data Circuit
  3578. ST     Send Timing      DCE       Active                  N/A            Timing circuit for Transmitted
  3579.                                                                          Data when DCE provides timing.
  3580. RT     Receive Timing   DCE       Active          N/A                    Timing circuit for Received
  3581.                                                                          Data when DCE provides timing.
  3582. LL     Local Loopback   DTE       Active          OFF                    Initialized to OFF by PSN software.
  3583.                                                                          Available for Monitoring Center
  3584.                                                                          Control through XMOD.
  3585.  
  3586.  
  3587.                                                                           
  3588.  
  3589. NOTE:  N/A = Not Applicable
  3590. DCAC-350-180-( )                                                     9-8
  3591.  
  3592. 3.  Mechanical Characteristics.  All BELL 303 connectors offered for the 
  3593. C/30E meet the following specifications.
  3594.  
  3595.     a.  Interface Connectors.  The C/30E MMI/MML BELL 303 connector DC-37P 
  3596. type (male) connectors.
  3597.  
  3598.         (1)  Intermating dimensions are in accordance with EIA Standard 
  3599. 449, section 3.3.1.
  3600.  
  3601.         (2)  The means for C/30E DTE connectors to latch and unlatch from 
  3602. the latching blocks on the DCE connector are within the dimensions 
  3603. specified in EIA Standard 449, section 3.3.2.  DDN uses the English 4-40 
  3604. thread latching block.
  3605.  
  3606.     b.  Connector Contact Assignments.  All C/30E BELL 303 contact 
  3607. assignments, as shown in table 9-3, provide the DDN
  3608. standard node connector pinout.   The signals are used asspecified in EIA 
  3609. Standard 449 section 2.d.3.
  3610. DCAC-350-180-( )                                                     9-9
  3611.  
  3612.        TABLE 9-3.  DDN STANDARD NODE EIA-449 (DTE) CONNECTOR PINOUT
  3613.  
  3614.                                                                           
  3615.  
  3616. Pin     EIA     CCITT   Name
  3617.         ID      ID    
  3618.  
  3619. 8       SD      103     Send Data
  3620. 27      SG      102     Signal Ground
  3621. 12      ST      114     Send Timing
  3622. 31      SG      102     Signal Ground
  3623. 10      RD      104     Receive Data
  3624. 29      SG      102     Signal Ground
  3625. 6       RT      115     Receive Timing
  3626. 25      SG      102     Signal Ground
  3627. 11      LL      141     Local Loopback
  3628. 30      SG      102     Signal Ground
  3629.  
  3630.                                                                           
  3631. DCAC-350-180-( )                                                     9-10
  3632.  
  3633. 4.  Interconnecting Cables.
  3634.  
  3635.     a.  Interconnecting cables must be low capacitance, multiple twisted 
  3636. pair that result in  a transmission line with a nominal characteristic 
  3637. impedance on the order of 100 ohms to frequencies greater than 100 kHz, 
  3638. and a dc series loop resistance not exceeding 240 ohms.  The overall braid 
  3639. shield must have at least 85% coverage.
  3640.  
  3641.         (1)  Conductor Size.  Interconnecting cables or wires should be 
  3642. composed of wires of a 24 AWG or larger conductor for solid or stranded 
  3643. copper wires, or for non-copper conductors a sufficient size to yield a dc 
  3644. wire resistance not to exceed 30 ohms/1000 feet per conductor.
  3645.  
  3646.         (2)  Mutual Pair Capacitance.  The capacitance between one  wire  
  3647. in the pair to the other wire in the pair  should  not exceed  20 
  3648. picofarads/foot,  and the value should  be  reasonably uniform over the 
  3649. length of the wire or cable. 
  3650.  
  3651.         (3)  Stray Capacitance.  The capacitance between one wire  in  the 
  3652. cable to all others in the cable sheath,  with  all others connected to 
  3653. ground, should not exceed 40 picofarads/foot,and should be reasonably 
  3654. uniform for a given conductor over the length of the wire or cable.
  3655.  
  3656.         (4)  Pair-to-Pair Balanced Crosstalk.  The crosstalk from on pair 
  3657. of wires to any other pair in the same cable sheath should have a minimum 
  3658. value of 40 dB attenuation measured at 150 kHz.
  3659. DCAC-350-180-( )                                                     9-11
  3660.  
  3661.     b.  Figure 9-1 is a cabling diagram of a C/30E PSN connected to a 
  3662. nearby BELL 303 PSN, and figure 9-2 is an example of a cable used to 
  3663. interconnect them.
  3664.  
  3665.  
  3666.  
  3667.  
  3668.  
  3669.  
  3670.  
  3671.  
  3672.  
  3673.    +-------------------------------------------------------------------+
  3674.    |                                                                   |
  3675.    |   C/30E PSN                                          C/30E PSN    |
  3676.    | +------------+                                     +------------+ |
  3677.    | |    MMI     |                                     |     MML    | |
  3678.    | |            |2405538601              R 2405538601 |            | |
  3679.    | | BELL - 303 |-------------------------------------| BELL - 303 | |
  3680.    | |            |                                     |            | |
  3681.    | |    DTE     |                                     |            | |
  3682.    | +------------+                                     +------------+ |
  3683.    |                                                                   |
  3684.    +-------------------------------------------------------------------+
  3685.  
  3686.          FIGURE 9-1.  BELL 303 MMI TO BELL 303 MML CABLING EXAMPLE
  3687. DCAC-350-180-( )                                                     9-12
  3688.  
  3689.  
  3690.  
  3691.  
  3692.  
  3693.  
  3694.  
  3695.  
  3696.  
  3697.        +-----------------------------------------------------------+
  3698.        |      C/30E                                       C/30E    |
  3699.        |        P1                                         P2      |
  3700.        |      DC-37S                                      DC-37P   |
  3701.        | Pin#     Signal                            Signal    Pin# |
  3702.        |  +/-       +/-   Shield             Shield   +/-      +/- |
  3703.        |  1         FG  >--------+         +-------<  FG       1   |
  3704.        |                                                           |
  3705.        |                                                           |
  3706.        |                 Pair #                                    |
  3707.        |  8/27      SD  >-(1)----------------------<  SD      8/27 |
  3708.        |                                                           |
  3709.        |  12/31     ST  >-(2)----------------------<  ST     12/31 |
  3710.        |                                                           |
  3711.        |  10/29     RD  >-(3)----------------------<  RD     10/29 |
  3712.        |                                                           |
  3713.        |  6/25      RC  >-(4)----------------------<  RC      6/25 |
  3714.        |                                                           |
  3715.        |  11/30     LL  >-(5)----------------------<  LL     11/30 |
  3716.        |                                                           |
  3717.        +-----------------------------------------------------------+
  3718.  
  3719.            FIGURE 9-2.  BELL 303 TRUNK INTERFACE CABLING EXAMPLE
  3720. DCAC-350-180-( )                                                     10-1
  3721.  
  3722.                CHAPTER 10.  BELL 303 REMOTE TRUNK INTERFACE
  3723.  
  3724. 1.  Overview.  This chapter describes the electrical and mechanical
  3725. characteristics of the BELL 303 balanced remote trunk interface.  This
  3726. chapter documents the interface between the remote modem and the PSN
  3727. (demarcation point A in figure 10-1) with no intervening cryptographic
  3728. devices (KG-84As).  The DDN standard is a MIL-STD-188-114 balanced
  3729. interface, and the BELL 303 is used only when it is not feasible to
  3730. install the standard. DDN supports Extended Modem Looping (XMOD)
  3731. through the BELL 303 interface.
  3732.  
  3733. 2.  Electrical Characteristics.
  3734.  
  3735.     a. Voltage Levels and Signaling Sense.  The modems used will conform 
  3736. to BELL 303.
  3737.  
  3738.     b.  Clocking.
  3739.  
  3740.         (1)  Modem Clocking.  The modem supplies timing on the Send Timing 
  3741. and Receive Timing circuits.  Terminal Timing is not supported for remote 
  3742. PSN interfaces.  While the DDN hardware will support between 1.2 kb/s and 
  3743. 64 kb/s, DDN policy is that the minimum PSN access rate be 9.6 kb/s.
  3744.  
  3745. DCAC-350-180-( )                                                     10-2
  3746.  
  3747.  
  3748.  
  3749.  
  3750.  
  3751.  
  3752.  
  3753.  
  3754.  
  3755.      +--------------------------------------------------------------+
  3756.      |                                                              |
  3757.      |                                                              |
  3758.      | C/30E PSN                                          PSN       |
  3759.      | +----------+     +----------+  +---------+     +-----------+ |
  3760.      | |          |     |          |  |         |     |           | |
  3761.      | |BELL - 303|-----|BELL -303 |--|BELL -303|-----| BELL -303 | |
  3762.      | |   DTE    | /|\ |  DCE     |  |  DCE    | /|\ |           | |
  3763.      | |          |  |  |          |  |         |  |  |           | |
  3764.      | +----------+  |  +----------+  +---------+  |  +-----------+ |
  3765.      |               |                             |                |
  3766.      |               |                             |                |
  3767.      |         2405537601                    R 2405537601           |
  3768.      |                                                              |
  3769.      +--------------------------------------------------------------+
  3770.  
  3771.      FIGURE 10-1.  DEMARCATION POINT "A" BETWEEN THE C/30E AND REMOTE
  3772.                    C/30E  
  3773. DCAC-350-180-( )                                                     10-3
  3774.  
  3775.     c.  Bit Rate and Cable Length.
  3776.  
  3777.         (1)  Maximum Cable Length.  The maximum cable length between the 
  3778. remote modem and the PSN is 50 feet; however, in some special applications 
  3779. cable lengths more  than  200 feet are possible.   Refer to the BELL 303  
  3780. specification section 7.0 for details. 
  3781.  
  3782.     d.  Interchange Circuits.
  3783.  
  3784.         (1)  C/30E Local Modem Interface.
  3785.  
  3786.              (a)  Signal flow between the C/30E and the local modem is 
  3787. shown in figure 6-3.  This interface and associated hardware are provided 
  3788. by DDN.  This DCE interface uses BELL 303 pin assignments.
  3789.  
  3790.              (b)  As shown in figure 10-2, the supported signals are Send 
  3791. Data (SD), Serial Clock Transmit (ST), Receive Data (RD), and Serial Clock 
  3792. Receive (SR) and Local Test (LL).
  3793.  
  3794. 3.  Mechanical Characteristics.
  3795.  
  3796.     a.  Interface Connectors.  The PSN end of the cable has a connector  
  3797. of  the DC-37S type (female) and the DCE  end  of  the cable  connector  
  3798. has  a  Burndy MD12MXP-17TC  plug  with a  Burndy M2H50RC-1P2 protective 
  3799. shield.
  3800.  
  3801. DCAC-350-180-( )                                                     10-4
  3802.  
  3803.     b.  Connector Contact Assignments.  Table 10-1 provides the standard 
  3804. DTE pinouts.  Table 10-2 provides the standard  DCE pinouts, and section 
  3805. 2.d.3 of the EIA Standard 449 provides circuit descriptions.
  3806. DCAC-350-180-( )                                                     10-5
  3807.  
  3808.  
  3809.  
  3810.  
  3811.  
  3812.  
  3813.  
  3814.  
  3815.  
  3816.        +-----------------------------------------------------------+
  3817.        |      C/30E                                       C/30E    |
  3818.        |        P1                                         P2      |
  3819.        |      DC-37S                                      DC-37P   |
  3820.        | Pin#     Signal                            Signal    Pin# |
  3821.        |  +/-       +/-   Shield             Shield   +/-      +/- |
  3822.        |  1             >--------+         +-------<           1   |
  3823.        |                                                           |
  3824.        |                                                           |
  3825.        |                 Pair #                                    |
  3826.        |  8/27      SD  >-(1)----------------------<  SD  E/SLEEVE |
  3827.        |                                                           |
  3828.        |  12/31     ST  >-(2)----------------------<  ST  J/SLEEVE |
  3829.        |                                                           |
  3830.        |  10/29     RD  >-(3)----------------------<  RD  K/SLEEVE |
  3831.        |                                                           |
  3832.        |  6/25      RC  >-(4)----------------------<  RC  L/SLEEVE |
  3833.        |                                                           |
  3834.        |  11/30     LL  >-(5)----------------------<  LL  G/SLEEVE |
  3835.        |                                                           |
  3836.        +-----------------------------------------------------------+
  3837.  
  3838.         FIGURE 10-2.  BELL 303 REMOTE TRUNK INTERCHANGE CIRCUIT USE
  3839. DCAC-350-180-( )                                                     10-6
  3840.  
  3841.                 TABLE 10-1.  DTE INTERFACE CONNECTOR PINOUT
  3842.  
  3843.                                                                           
  3844.  
  3845.         Pin     EIA     CCITT      Name   
  3846.                 ID      ID    
  3847.  
  3848.         8       SD      103        Send Data
  3849.         27      SG      102        Signal Ground
  3850.         12      ST      114        Send Timing
  3851.         31      SG      102        Signal Ground
  3852.         10      RD      104        Receive Data
  3853.         29      SG      102        Signal Ground
  3854.         6       RT      115        Receive Timing
  3855.         25      SG      102        Signal Ground
  3856.         11      LL      141        Local Loopback
  3857.         30      SG      102        Signal Ground
  3858.  
  3859.                                                                           
  3860.  
  3861. DCAC-350-180-( )                                                     10-7
  3862.  
  3863.             TABLE 10-2.  DCE BELL 303 INTERFACE CONECTOR PINOUT
  3864.  
  3865.                                                                           
  3866.  
  3867.         Pin         EIA     CCITT         Name
  3868.                     ID      ID            
  3869.  
  3870. Mandatory
  3871.  
  3872.         E           SD      103           Send Data             
  3873.         SLEEVE      SG      102           Signal Ground         
  3874.         J           ST      114           Send Timing           
  3875.         SLEEVE      SG      102           Signal Ground
  3876.         K           RD      104           Receive Data          
  3877.         SLEEVE      SG      102           Signal Ground         
  3878.         L           RT      115           Receive Timing        
  3879.         SLEEVE      SG      102           Signal Ground
  3880.  
  3881. Optional
  3882.  
  3883.         G           LL      141           Local Loopback
  3884.         SLEEVE      SG      102           "D" Loop (Reserved)   
  3885.  
  3886.                                                                           
  3887.  
  3888. DCAC-350-180-( )                                                     10-8
  3889.  
  3890.              TABLE 10-3  KGAB - REMOTE MODEM CONNECTOR PINOUT
  3891.  
  3892.                                                                           
  3893.  
  3894.         Pin         EIA     CCITT         Name
  3895.                     ID      ID
  3896.  
  3897. Mandatory
  3898.  
  3899.         1           FG                    Frame Ground
  3900.         2           SD +    103           Send Data
  3901.         3           SD -    103           Send Data
  3902.         4           ST +    114           Send Timing
  3903.         5           ST -    114           Send Timing
  3904.         6           RD +    104           Receive Data
  3905.         7           RD -    104           Receive Data
  3906.         8           RT +    115           Receive Timing
  3907.         9           RT -    115           Receive Timing
  3908.         10          TR +    108.2         Terminal Ready
  3909.         11          TR -    108.2         Terminal Ready
  3910.         14          SG      102           Signal Ground
  3911.         15          SG      102           Signal Ground
  3912.         24          TT +    113           Terminal Timing
  3913.         25          TT -    113           Terminal Timing
  3914.  
  3915. Optional
  3916.  
  3917.         12          CS +    106           Clear to Send
  3918.         13          CS -    106           Clear to Send
  3919.         16          CL +    ---           "C" Loop (KG-84A Loop)
  3920.         17          CL -    ---           "C" Loop (KG-84A Loop)
  3921.         18          RL +    140           Remote Loopback
  3922.         19          RL -    140           Remote Loopback
  3923.         20          DL +    ---           "D" Loop (Reserved)
  3924.         21          DL -    ---           "D" Loop (Reserved)
  3925.         22          LL +    141           Local Loopback
  3926.         23          LL -    141           Local Loopback
  3927.  
  3928.                                                                           
  3929.  
  3930. DCAC-350-180-( )                                                     10-9
  3931.  
  3932. 4.  Interconnecting Cables.  Figure 10-1 provides a cabling diagram of a 
  3933. configuration with a C/30E and a BELL 303 modem. Table 10-3 describes the 
  3934. cable used for interconnecting these devices.
  3935.  
  3936.  
  3937.  
  3938.  
  3939.                     TABLE 10-3. REMOTE INTERFACE CABLES
  3940.  
  3941.                                                                           
  3942.  
  3943. Connection               BBNCC         Description
  3944.                          P/N#
  3945.  
  3946. PSN IMP/MII to BELL 303  2405537G01    5-pr, PSN/MII BELL 303
  3947.                                        to BELL 303 Modem
  3948.  
  3949.                                                                           
  3950. 
  3951.